directional sensitivity
Recently Published Documents


TOTAL DOCUMENTS

311
(FIVE YEARS 40)

H-INDEX

38
(FIVE YEARS 3)

Author(s):  
Lawrence Labrecque ◽  
Joel S. Burma ◽  
Marc-Antoine Roy ◽  
Jonathan David Smirl ◽  
Patrice Brassard

The cerebral pressure-flow relationship has directional sensitivity, meaning the augmentation in cerebral blood flow is attenuated when mean arterial pressure (MAP) increases vs MAP decreases. We employed repeated squat-stands (RSS) to quantify it using a novel metric. However, its within-day reproducibility and the impacts of diurnal variation and biological sex are unknown. Study aims were to evaluate this metric for: 1) within-day reproducibility and diurnal variation in middle (MCA; ∆MCAvT/∆MAPT) and posterior cerebral arteries (PCA; ∆PCAvT/∆MAPT); 2) sex differences. ∆MCAvT/∆MAPT and ∆PCAvT/∆MAPT were calculated at seven time-points (08:00-17:00) in 18 participants (8 women; 24 ± 3 yrs) using the minimum-to-maximum MCAv or PCAv and MAP for each RSS at 0.05 Hz and 0.10 Hz. Relative metric values were also calculated (%MCAvT/%MAPT, %PCAvT/%MAPT). Intraclass correlation coefficient (ICC) evaluated reproducibility, which was good (0.75-0.90) to excellent (>0.90). Time-of-day impacted ∆MCAvT/∆MAPT (0.05 Hz: p = 0.002; 0.10 Hz: p = 0.001), %MCAvT/%MAPT (0.05 Hz: p = 0.035; 0.10 Hz: p = 0.009), and ∆PCAvT/∆MAPT (0.05 Hz: p = 0.024), albeit with small/negligible effect sizes. MAP direction impacted both arteries' metric at 0.10 Hz (all p < 0.024). Sex differences in the MCA only (p = 0.003) vanished when reported in relative terms. These findings demonstrate this metric is reproducible throughout the day in the MCA and PCA and is not impacted by biological sex.


2021 ◽  
pp. 1-11
Author(s):  
Eileanor P. LaRocco ◽  
Glenn A. Proudfoot ◽  
Megan D. Gall

Many animals use sound as a medium for detecting or locating potential prey items or predation threats. Northern saw-whet owls (<i>Aegolius acadicus</i>) are particularly interesting in this regard, as they primarily rely on sound for hunting in darkness, but are also subject to predation pressure from larger raptors. We hypothesized that these opposing tasks should favor sensitivity to low-frequency sounds arriving from many locations (potential predators) and high-frequency sounds below the animal (ground-dwelling prey items). Furthermore, based on the morphology of the saw-whet owl skull and the head-related transfer functions of related species, we expected that the magnitude of changes in sensitivity across spatial locations would be greater for higher frequencies than low frequencies (i.e., more “directional” at high frequencies). We used auditory-evoked potentials to investigate the frequency-specific directional sensitivity of Northern saw-whet owls to acoustic signals. We found some support for our hypothesis, with smaller-magnitude changes in sensitivity across spatial locations at lower frequencies and larger-magnitude changes at higher frequencies. In general, owls were most sensitive to sounds originating in front of and above their heads, but at 8 kHz there was also an area of high sensitivity below the animals. Our results suggest that the directional hearing of saw-whet owls should allow for both predator and prey detection.


Sensors ◽  
2021 ◽  
Vol 21 (21) ◽  
pp. 7345
Author(s):  
Rohan Soman ◽  
Junghyun Wee ◽  
Kara Peters

Guided waves (GW) and acoustic emission (AE) -based structural health monitoring (SHM) have widespread applications in structures, as the monitoring of an entire structure is possible with a limited number of sensors. Optical fiber-based sensors offer several advantages, such as their low weight, small size, ability to be embedded, and immunity to electro-magnetic interference. Therefore, they have long been regarded as an ideal sensing solution for SHM. In this review, the different optical fiber technologies used for ultrasonic sensing are discussed in detail. Special attention has been given to the new developments in the use of FBG sensors for ultrasonic measurements, as they are the most promising and widely used of the sensors. The paper highlights the physics of the wave coupling to the optical fiber and explains the different phenomena such as directional sensitivity and directional coupling of the wave. Applications of the different sensors in real SHM applications have also been discussed. Finally, the review identifies the encouraging trends and future areas where the field is expected to develop.


2021 ◽  
Vol 81 (11) ◽  
Author(s):  
P. Agnes ◽  
S. Albergo ◽  
I. Albuquerque ◽  
M. Arba ◽  
M. Ave ◽  
...  

AbstractA double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of the ReD project is to investigate the directional sensitivity of argon-based TPCs via columnar recombination to nuclear recoils in the energy range of interest (20–$$200\,\hbox {keV}_{nr}$$ 200 keV nr ) for direct dark matter searches. The key novel feature of the ReD TPC is a readout system based on cryogenic Silicon Photomultipliers (SiPMs), which are employed and operated continuously for the first time in an argon TPC. Over the course of 6 months, the ReD TPC was commissioned and characterised under various operating conditions using $$\gamma $$ γ -ray and neutron sources, demonstrating remarkable stability of the optical sensors and reproducibility of the results. The scintillation gain and ionisation amplification of the TPC were measured to be $$g_1 = (0.194 \pm 0.013)$$ g 1 = ( 0.194 ± 0.013 ) photoelectrons/photon and $$g_2 = (20.0 \pm 0.9)$$ g 2 = ( 20.0 ± 0.9 ) photoelectrons/electron, respectively. The ratio of the ionisation to scintillation signals (S2/S1), instrumental for the positive identification of a candidate directional signal induced by WIMPs, has been investigated for both nuclear and electron recoils. At a drift field of 183 V/cm, an S2/S1 dispersion of 12% was measured for nuclear recoils of approximately 60–$$90\,\hbox {keV}_{nr}$$ 90 keV nr , as compared to 18% for electron recoils depositing 60 keV of energy. The detector performance reported here meets the requirements needed to achieve the principal scientific goals of the ReD experiment in the search for a directional effect due to columnar recombination. A phenomenological parameterisation of the recombination probability in LAr is presented and employed for modeling the dependence of scintillation quenching and charge yield on the drift field for electron recoils between 50–500 keV and fields up to 1000 V/cm.


Author(s):  
Kuang Bai ◽  
Jane J. Ye

The bilevel program is an optimization problem in which the constraint involves solutions to a parametric optimization problem. It is well known that the value function reformulation provides an equivalent single-level optimization problem, but it results in a nonsmooth optimization problem that never satisfies the usual constraint qualification, such as the Mangasarian–Fromovitz constraint qualification (MFCQ). In this paper, we show that even the first order sufficient condition for metric subregularity (which is, in general, weaker than MFCQ) fails at each feasible point of the bilevel program. We introduce the concept of a directional calmness condition and show that, under the directional calmness condition, the directional necessary optimality condition holds. Although the directional optimality condition is, in general, sharper than the nondirectional one, the directional calmness condition is, in general, weaker than the classical calmness condition and, hence, is more likely to hold. We perform the directional sensitivity analysis of the value function and propose the directional quasi-normality as a sufficient condition for the directional calmness. An example is given to show that the directional quasi-normality condition may hold for the bilevel program.


Nano Letters ◽  
2021 ◽  
Vol 21 (19) ◽  
pp. 8304-8310
Author(s):  
Nathan Dvořák ◽  
Kunook Chung ◽  
Kobie Mueller ◽  
Pei-Cheng Ku

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yan Hu ◽  
Jianfeng Ren ◽  
Jianlong Yang ◽  
Ruibing Bai ◽  
Jiang Liu

AbstractOptical coherence tomography (OCT) images is widely used in ophthalmic examination, but their qualities are often affected by noises. Shearlet transform has shown its effectiveness in removing image noises because of its edge-preserving property and directional sensitivity. In the paper, we propose an adaptive denoising algorithm for OCT images. The OCT noise is closer to the Poisson distribution than the Gaussian distribution, and shearlet transform assumes additive white Gaussian noise. We hence propose a square-root transform to redistribute the OCT noise. Different manufacturers and differences between imaging objects may influence the observed noise characteristics, which make predefined thresholding scheme ineffective. We propose an adaptive 3D shearlet image filter with noise-redistribution (adaptive-SIN) scheme for OCT images. The proposed adaptive-SIN is evaluated on three benchmark datasets using quantitative evaluation metrics and subjective visual inspection. Compared with other algorithms, the proposed algorithm better removes noise in OCT images and better preserves image details, significantly outperforming in terms of both quantitative evaluation and visual inspection. The proposed algorithm effectively transforms the Poisson noise to Gaussian noise so that the subsequent shearlet transform could optimally remove the noise. The proposed adaptive thresholding scheme optimally adapts to various noise conditions and hence better remove the noise. The comparison experimental results on three benchmark datasets against 8 compared algorithms demonstrate the effectiveness of the proposed approach in removing OCT noise.


2021 ◽  
Vol 15 ◽  
Author(s):  
Basile Tarchini

Sensory hair cells detect mechanical stimuli with their hair bundle, an asymmetrical brush of actin-based membrane protrusions, or stereocilia. At the single cell level, stereocilia are organized in rows of graded heights that confer the hair bundle with intrinsic directional sensitivity. At the organ level, each hair cell is precisely oriented so that its intrinsic directional sensitivity matches the direction of mechanical stimuli reaching the sensory epithelium. Coordinated orientation among neighboring hair cells usually ensures the delivery of a coherent local group response. Accordingly, hair cell orientation is locally uniform in the auditory and vestibular cristae epithelia in birds and mammals. However, an exception to this rule is found in the vestibular macular organs, and in fish lateral line neuromasts, where two hair cell populations show opposing orientations. This mirror-image hair cell organization confers bidirectional sensitivity at the organ level. Here I review our current understanding of the molecular machinery that produces mirror-image organization through a regional reversal of hair cell orientation. Interestingly, recent evidence suggests that auditory hair cells adopt their normal uniform orientation through a global reversal mechanism similar to the one at work regionally in macular and neuromast organs. Macular and auditory organs thus appear to be patterned more similarly than previously appreciated during inner ear development.


2021 ◽  
Author(s):  
Amada Abrego Mancilla ◽  
Wasif Khan ◽  
Christopher E Wright ◽  
Neela Prajapati ◽  
M Rabiul Islam ◽  
...  

A variety of electrophysiology tools are available to the neurosurgeon for diagnosis, functional therapy, and neural prosthetics. However, no tool can currently address these three critical recording needs: (i) a surgical method that can reach any cortical region in a minimally invasive manner; (ii) record microscale, mesoscale, and macroscale resolutions simultaneously; and (iii) enable recording from multiple brain regions. This work presents a novel device for recording local field potentials (LFPs) whose form is based on state-of-the-art stereo-electroencephalogram (sEEG). Using quasi-static electromagnetic modeling, the lead body is shown to shield LFP sources and this enables directional sensitivity and scalability when microelectrodes are positioned radially, which we refer to as a DISC array. As predicted, DISC demonstrated significantly improved signal-to-noise, directional sensitivity, and decoding accuracy in the rat barrel cortex during whisker stimulation. Critically, DISC also demonstrated equivalent fidelity at the macroscale and, uniquely, performs current source density in stereo. Directional sensitivity of LFPs may significantly improve brain-computer interfaces and many diagnostic procedures, including epilepsy foci detection and deep brain targeting.


Author(s):  
David Murphy ◽  
Alexey Ulyanov ◽  
Sheila McBreen ◽  
Maeve Doyle ◽  
Rachel Dunwoody ◽  
...  

AbstractThe Educational Irish Research Satellite 1 (EIRSAT-1) is a 2U CubeSat being developed under ESA’s Fly Your Satellite! programme. The project has many aspects, which are primarily educational, but also include space qualification of new detector technologies for gamma-ray astronomy and the detection of gamma-ray bursts (GRBs). The Gamma-ray Module (GMOD), the main mission payload, is a small gamma-ray spectrometer comprising a 25 mm × 25 mm × 40 mm cerium bromide scintillator coupled to an array of 16 silicon photomultipliers. The readout is provided by IDE3380 (SIPHRA), a low-power and radiation tolerant readout ASIC. GMOD will detect gamma-rays and measure their energies in a range from tens of keV to a few MeV. Monte Carlo simulations were performed using the Medium Energy Gamma-ray Astronomy Library to evaluate GMOD’s capability for the detection of GRBs in low Earth orbit. The simulations used a detailed mass model of the full spacecraft derived from a very high-fidelity 3D CAD model. The sky-average effective area of GMOD on board EIRSAT-1 was found to be 10 cm2 at 120 keV. The instrument is expected to detect between 11 and 14 GRBs, at a significance greater than 10σ (and up to 32 at 5σ), during a nominal one-year mission. The shape of the scintillator in GMOD results in omni-directional sensitivity which allows for a nearly all-sky field of view.


Sign in / Sign up

Export Citation Format

Share Document