Ocular biometric changes after Ahmed glaucoma valve implantation

2019 ◽  
pp. 112067211988952
Author(s):  
Arezoo Miraftabi ◽  
Mahboubeh Lotfi ◽  
Naveed Nilforushan ◽  
Parya Abdolalizadeh ◽  
Samira Jafari

Purpose: To investigate the ocular biometric changes after uneventful Ahmed glaucoma valve implantation. Methods: Patients with refractory glaucoma who were candidate for Ahmed valve surgery were prospectively included in this study. Patients with a history of any kinds of corneal surgery were excluded. Refractive status, intraocular pressure, axial length, anterior chamber parameters including anterior and posterior mean keratometry, central corneal thicknesses, and anterior chamber depth, anterior chamber volume, and anterior chamber angle were evaluated at baseline and 1 and 3 months after surgery. Results: A total of 20 eyes from 20 patients were included. Mean intraocular pressure at baseline was 33.4 ± 12.3 mm Hg that significantly decreased to 14.6 ± 6.2 mm Hg at 1 month and 13.5 ± 4.3 mm Hg at 3 months after Ahmed glaucoma valve implantation ( p < 0.001). Mean number of medications was 3.6 ± 1.3 at baseline which significantly decreased to 1.0 ± 1.3 at 3 months after Ahmed glaucoma valve implantation ( p < 0.001). Axial length decreased significantly from 23.69 ± 1.95 to 23.47 ± 1.91 mm ( p < 0.001) at month 3. There were no significant changes in other parameters such as mean spherical equivalent, anterior chamber volume, anterior chamber angle, anterior chamber depth, and keratometry at the end of month 3 after surgery ( p > 0.05 in all). Conclusion: Ahmed glaucoma valve implantation had a significant effect on axial length at 3 months after surgery but its effect on keratometry and other anterior chamber parameters was not significant.

2018 ◽  
Vol 2018 ◽  
pp. 1-4
Author(s):  
Ertuğrul Tan Yassa ◽  
Cihan Ünlü

Purpose. We aimed to investigate whether anterior chamber angle, depth, and volume change after myopic laser-assisted in situ keratomileusis (LASIK) in young patients. Methods. This retrospective study included 29 eyes of 29 patients (15 females and 14 males) between the ages of 18 and 39 years who underwent LASIK for the treatment of myopia. In addition to complete ophthalmic examination, anterior chamber angle (ACA), central anterior chamber depth (ACD), and anterior chamber volume (ACV) were measured by using a Sirius rotating Scheimpflug camera combined with Placido disc corneal topography (CSO, Florence, Italy). Preoperative and postoperative values were compared using paired t-tests. Linear regression was used to evaluate the relationship between changes in refraction and changes in ACA, ACD, and ACV as well as between attempted maximum ablation depth and changes in ACA, ACD, and ACV. Results. The mean age of the study population was 25.5 ± 6.2 years. The mean preoperative and postoperative spherical equivalent values were −3.30 ± 1.92 D and −0.18 ± 0.29 D, respectively. ACV and ACA were not significantly changed after surgery; however, central ACD was significantly decreased (preoperatively = 3.366 ± 0.316 mm vs postoperatively = 3.3 ± 0.298 mm) with a mean difference of 0.066 ± 1.121 mm. There were no significant relationships between changes in refraction and anterior segment dimensions or between attempted maximum ablation depth and anterior segment dimensions. Conclusion. Measurements with Sirius showed that ACA and ACV did not change; however, central ACD significantly decreased after myopic LASIK in young patients, indicating that the preoperative central ACD value should not be used interchangeably with the postoperative central ACD value.


2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
Wakako Ikegawa ◽  
Takashi Suzuki ◽  
Koji Namiguchi ◽  
Shiro Mizoue ◽  
Atsushi Shiraishi ◽  
...  

Purpose. To quantify changes in anterior segment (AS) parameters after laser peripheral iridotomy (LPI) using AS-optical coherence tomography (OCT) of iris bombe. Method. AS images of eight eyes were captured before and after iris bombe and more than 2 weeks after LPI (post-LPI) using AS-OCT. We compared the following AS parameters: anterior chamber depth (ACD), anterior chamber volume (ACV), iris curvature (IC), iris thickness at 500 μm from the scleral spur (IT-1) in the middle between the iris root and pupillary margin (IT-2) and 500 μm from the pupillary margin (IT-3) to the anterior chamber angle (ACA) (angle opening distance [AOD750]), and trabecular iris space area. Results. Mean IT-1 and IT-3, but not IT-2, were lower after iris bombe (IT-1, P=0.001; IT-2, P=0.081; and IT-3, P=0.001). There were no significant differences between ACD at pre-LPI and before iris bombe (P=0.096). The mean ACV and AOD750 of iris bombe increased at post-LPI (ACV, P<0.01, and AOD750, P<0.05). The mean IT-1, IT-2, and IT-3 increased at post-LPI (all, P≤0.01). IC decreased at post-LPI (P<0.001), and ACD at post-LPI did not change. Conclusions. The iris extends and becomes thinner during iris bombe. LPI during bombe decreases the IC and increases the ACV and ACA.


2016 ◽  
Vol 42 (4) ◽  
pp. 244-249 ◽  
Author(s):  
Hassan Hashemi ◽  
Mehdi Khabazkhoob ◽  
Saman Mohazzab-Torabi ◽  
Mohammad Hassan Emamian ◽  
Mohammad Shariati ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-4 ◽  
Author(s):  
Ercan Ozsoy ◽  
Abuzer Gunduz ◽  
Ersin Ersan Demirel ◽  
Tongabay Cumurcu

Purpose. To evaluate anterior segment’s structures by Pentacam in patients with tilted disc syndrome (TDS).Methods. Group 1 included forty-six eyes of forty-six patients who have the TDS. Group 2 including forty-six eyes of forty-six cases was the control group which was equal to the study group in age, gender, and refraction. A complete ophthalmic examination was performed in both groups. All cases were evaluated by Pentacam. The axial length (AL) of eyes was measured by ultrasound. Quantitative data obtained from these measurements were compared between two groups.Results. There was no statistically significant difference for age, gender, axial length, and spherical equivalent measurements between two groups (p=0.625,p=0.830,p=0.234, andp=0.850). There was a statistically significant difference for central corneal thickness (CCT), corneal volume (CV), anterior chamber angle (ACA), and pupil size measurements between two groups (p=0.001,p=0.0001,p=0.003, andp=0.001). Also, there was no statistically significant difference for anterior chamber depth (ACD), anterior chamber volume (ACV), and lens thickness (LT) measurements between two groups (p=0.130,p=0.910, andp=0.057).Conclusion. We determined that CCT was thinner, CV was less, and ACA was narrower in patients with TDS. There are some changes in the anterior segment of the eyes with tilted disc.


2016 ◽  
Vol 25 (8) ◽  
pp. 692-697 ◽  
Author(s):  
Peiyao Jin ◽  
Meili Li ◽  
Xiangui He ◽  
Lina Lu ◽  
Jianfeng Zhu ◽  
...  

2013 ◽  
Vol 94 (6) ◽  
pp. 853-858
Author(s):  
A A Ryabtseva ◽  
M P Yugaj ◽  
N S Nikitina

Aim. To study the changes of anatomic and topographic characteristics of the eye anterior segment after uncomplicated cataract phacoemulsification using corneal incision with intraocular soft lens implantation. Methods. The data of ultrasound biomicroscopy and noncontact tonometry of 58 eyes (56 patients, 32 females, 24 males aged 54 to 78 years) before and after cataract phacoemulsification were analyzed. Paitents with survived ocular trauma, refractive keratoplasty, glaucoma, uveitis, and surgical complications (incomplete capsulorrhexis, posterior capsule rupture, ciliary zonule disinsertion, corneal burn). Apart from the common examinations (visual acuity testing, tonometry, tonography, eye A- and B-ultrasonography, biomicroscopy), all patients underwent eye ultrasound biomicroscopy. Results. Anterior chamber depth increased from 2.73±0.10 to 4.17±0.06 mm (p ≤0.001). Trabecula-iris distance measured at 500 μm from the scleral spur, increased from 0.38±0.02 to 0.47±0.02 mm (p ≤0.001). Anterior chamber angle increased from 28.69±1.87 to 42.73±1.56 degrees (p ≤0.001), the angle between the iris and the sclera increased from 32.78±1.39 to 41.36±0.84 degrees (p ≤0.001), the angle between the sclera and ciliary processes increased from 39.48±1.29 to 45.30±1.16 degrees (p ≤0.001). Intraocular pressure according to the non-contact tonometry data decreased from 18.16±1.29 to 13.55±0.95 mm Hg (p ≤0.001). Conclusion. Anterior chamber depth, trabecula-iris distance, anterior chamber angle, the angle between sclera and iris and the angle between sclera and ciliary processes increased significantly after phacoemulsification with intraocular lens implantation. Intraocular pressure decreased significantly according to the non-contact tonometry data.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Poemen Pui-man Chan ◽  
Gilda Lai ◽  
Vivian Chiu ◽  
Anita Chong ◽  
Marco Yu ◽  
...  

Abstract This study compared the test–retest variabilities and measurement agreement of anterior chamber angle (ACA) dimensions measured by two anterior segment swept-source optical coherence tomography (SS-OCT)—the ANTERION (Heidelberg Engineering, Heidelberg, Germany) and CASIAII (Tomey, Nagoya, Japan). Thirty-eight subjects, 18 patients with primary angle closure and 20 healthy participants with open angles, were included. The mean age was 54.7 ± 15.8 years (range: 26–75 years). One eye of each subject was randomly selected for anterior segment imaging by ANTERION and CASIAII, using the same scan pattern (6 evenly spaced radial scans across the anterior segment for three times) in the same visit. The between- and within-instrument agreement and repeatability coefficients of angle open distance (AOD500), trabecular-iris space area (TISA500), lens vault (LV), scleral spur-scleral spur distance (SSD), anterior chamber depth (ACD), and pupil diameter (PD) were measured. The anterior and posterior boundaries of the cornea, iris, and lens were automatically segmented by the SS-OCT instruments; the scleral spur was manually located by a single masked observer. There were significant differences between ANTERION and CASIAII measurements; the SSD, PD, and ACD were smaller whereas AOD500 and TISA500 were greater in ANTERION compared with CASIAII (P < 0.001). Anterior segment measurements obtained from the two SS-OCT instruments showed strong associations (R2 ranged between 0.866 and 0.998) although the between-instrument agreement was poor; the spans of 95% limits of between-instrument agreement were ≥ 1.5-folds than the within-instrument agreement for either instrument. Whereas both SS-OCT instruments showed low test–retest measurement variabilities, the repeatability coefficients of AOD500, TISA500, ACD, and PD were slightly smaller for CASIAII than ANTERION (P ≤ 0.012).


2021 ◽  
Vol 14 (10) ◽  
pp. 1527-1532
Author(s):  
Qian Zheng ◽  
◽  
Zhang-Liang Li ◽  
Ping-Jun Chang ◽  
Yun-E Zhao ◽  
...  

AIM: To assess the changes of anterior chamber angle in patients with shallow anterior chamber after phacoemulsification combined with intraocular lens (IOL) implantation, based on anterior segment swept-source optical coherence tomography (AS-SS-OCT) measurements. METHODS: This was a prospective case control study; sixty eyes of sixty case were scheduled for cataract surgery with normal intraocular pressure (IOP). Based on anterior chamber depth (ACD) and gonioscopy findings, the eyes were divided into two groups: group of shallow anterior chamber and narrow angle (SAC group, 30 eyes); and group of normal anterior chamber group with wide angle (NAC group, 30 eyes). Measurements of ACD, anterior chamber volume (ACV), iris volume (IV), lens vault (LV), angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) were conducted in each group before and 3mo after surgery. RESULTS: There was no significant difference in age, axial length (AL), corneal curvature, corneal diameter, intraocular pressure, and IV between two groups before surgery, except for the LV (P=0.000). ACD and ACV were prominently larger in the NAC group than the SAC group 3mo after operation (3.69±0.38 vs 3.85±0.39 mm, P=0.025; 161.37±19.47 vs 178.26±20.30 mm3, P=0.002). AOD750, ARA750 in nasal and inferior quadrants, TISA750 in all quadrants except temporal, and TIA750 in all quadrants in SAC group were significantly smaller than those in NAC group after operation (all P<0.05). CONCLUSION: Cataract surgery can deepen anterior chamber and increase the width of anterior chamber angle in Chinese subjects, but the angle related parameters including AOD750, ARA750, TISA750, TIA, TISA750, and ACV in patients with shallow anterior chamber and narrow angle do not reach the normal level.


Sign in / Sign up

Export Citation Format

Share Document