scholarly journals Very delayed discontinuation of telescoped Pipeline embolization devices: a case report

2018 ◽  
Vol 25 (2) ◽  
pp. 182-186
Author(s):  
Manoj Bohara ◽  
Kosuke Teranishi ◽  
Kenji Yatomi ◽  
Takashi Fujii ◽  
Takayuki Kitamura ◽  
...  

Background Flow diversion with the Pipeline embolization device (PED) is a widely accepted treatment modality for aneurysm occlusion. Previous reports have shown no recanalization of aneurysms on long-term follow-up once total occlusion has been achieved. Case description We report on a 63-year-old male who had a large internal carotid artery cavernous segment aneurysm. Treatment with PED resulted in complete occlusion of the aneurysm. However, follow-up angiography at four years revealed recurrence of the aneurysm due to disconnection of the two PEDs placed in telescoping fashion. Conclusion Herein, we present the clinico-radiological features and discuss the possible mechanisms resulting in the recanalization of aneurysms treated with flow diversion.

2019 ◽  
Vol 10 (01) ◽  
pp. 142-144 ◽  
Author(s):  
Ching-Jen Chen ◽  
M. Rao Patibandla ◽  
Min S. Park ◽  
M. Yashar Kalani

ABSTRACTDespite the widespread use of the pipeline embolization device (PED), no complete aneurysm regrowth after its placement has been reported in the literature. We report the first case of aneurysm regrowth after the initial follow-up angiography demonstrating near-complete occlusion of the aneurysm and remodeling of the vessel with on-label PED use for a large 20 mm × 24 mm × 22 mm (width × depth × height) cavernous segment internal carotid artery (ICA) aneurysm. The patient was treated with two overlapping PED (4.5 mm × 20 mm and 5 mm × 20 mm). Follow-up angiogram at 4 months after treatment demonstrated remodeling of the ICA with a small residual component measuring approximately 7 mm × 8 mm × 7 mm. However, at 10 months after treatment, there was a complete regrowth of the aneurysm with interval growth, now measuring 25 mm × 28 mm × 18 mm. Despite the high aneurysm occlusion rates reported with the PED, persistent aneurysm filling and aneurysm regrowth, although rare, should not be overlooked.


2010 ◽  
Vol 67 (3) ◽  
pp. onsE313-onsE314 ◽  
Author(s):  
David Fiorella ◽  
Daniel Hsu ◽  
Henry H. Woo ◽  
Robert W. Tarr ◽  
Peter Kim Nelson

Abstract BACKGROUND: The Pipeline embolization device (PED) is a new endoluminal construct designed to exclude aneurysms from the parent cerebrovasculature. We report the very late (>;1 year) thrombosis of a PED construct placed for the treatment of a left vertebral aneurysm. CLINICAL PRESENTATION: A patient with an occluded right vertebral artery and a large, fusiform intracranial left vertebral artery aneurysm was treated with PED and coil reconstruction. A durable, complete occlusion of the aneurysm was confirmed with control angiography at 1 year. The patient remained neurologically normal for 23 months until he experienced a transient visual disturbance followed weeks later by a minor brainstem stroke. INTERVENTION: Imaging evaluation showed thrombosis of the PED construct with complete occlusion of the left vertebral artery. After this stroke, he was initially treated with dual antiplatelet therapy and was then converted to warfarin. The patient remained neurologically stable for 5 months until he experienced progressive basilar thrombosis that ultimately resulted in a fatal stroke. CONCLUSION: The PED represents a promising new endovascular technology for the treatment of cerebral aneurysms; however, as an investigational device, long-term follow-up data are sparse at this point. The etiology of the very late thrombosis of the PED construct in this case remains unknown; however, this report underscores the need for a continued, careful systematic evaluation and close long-term follow-up of treated patients.


2018 ◽  
Vol 24 (4) ◽  
pp. 363-374 ◽  
Author(s):  
Anna Luisa Kühn ◽  
Guilherme Dabus ◽  
Peter Kan ◽  
Ajay K Wakhloo ◽  
Ajit S Puri

Background Use of flow-diversion technology in the treatment of incidental and recanalized posterior communicating artery (PComA) aneurysms. Methods Patients treated with the Pipeline embolization device (PED) for PComA aneurysms were identified and included in our retrospective analysis. We evaluated aneurysm characteristics, modified Rankin Scale score (mRS) on admission, angiography follow-up, and patient clinical outcome at discharge, at three to nine months, and at 12–18 months. Results We included 56 patients with a mean age of 56 years. Median mRS on admission was 0. All aneurysms involved the PComA and were either new findings or found to have shown recanalization at angiography follow-up from previous coil embolization or surgical clipping. Intraprocedural device foreshortening was observed in one case requiring additional placement of a self-expanding stent. One intraprocedural aneurysm rupture occurred because of a broken distal wire. This patient had an mRS of 4 after the procedure. Three- to nine-month and 12- to 18-month follow-up angiography showed near complete or complete aneurysm occlusion in most cases. Minimal to mild intimal hyperplasia was seen in five cases at three to nine months. PComA patency over time showed 29 of 46 initially patent vessels still patent at six months. Thirteen and seven PComAs showed progressive decrease in flow at three to nine months and 12–18 months, respectively. Median mRS remained 0 for all patients at three- to nine-month and 12- to 18-month follow-up. Conclusions Our preliminary results show that flow-diversion technology is an effective and safe treatment option. Larger studies with long-term follow-up are needed to validate our promising results.


2020 ◽  
Vol 12 (Suppl. 1) ◽  
pp. 202-206
Author(s):  
Min Kyoung Kang ◽  
Byung-Woo Yoon

We report the case of long-term follow-up of brain magnetic imaging of cerebral amyloid angiopathy. Cerebral amyloid angiopathy is often considered a major cause of spontaneous intracerebral hemorrhage in the elderly. This case illustrates the markedly progressive clinical and radiological features of the vasculopathic process in 10 years.


2020 ◽  
Vol 72 (1) ◽  
Author(s):  
Mohammad Abdallah Eltahlawi ◽  
Abdel-Aziz Fouad Abdel-Aziz ◽  
Abdel-Salam Sherif ◽  
Khalid Abdel-Azeem Shokry ◽  
Islam Elsayed Shehata

Abstract Background We hypothesized that 1st generation everolimus-eluting bioresorbable vascular scaffold (BVS) stent associated with less complication and less restenosis rate than everolimus-eluting stent (EES) in chronic total occlusion (CTO) recanalization guided by intracoronary imaging. Therefore, we aimed to assess the safety and performance of BVS stent in CTO revascularization in comparison to EES guided by intracoronary imaging. Our prospective comparative cross-sectional study was conducted on 60 CTO patients divided into two groups according to type of stent revascularization: group I (EES group): 40 (66.7%) patients and group II (BVS group): 20 (33.3%) patients. All patients were subjected to history taking, electrocardiogram (ECG), echocardiography, laboratory investigation, stress thallium study to assess viability before revascularization. Revascularization of viable CTO lesion guided by intracoronary imaging using optical coherence tomography (OCT). Then, long-term follow-up over 1 year clinically and by multi-slice CT coronary angiography (MSCT). Our clinical and angiographic endpoints were to detect any clinical or angiographic complications during the follow-up period. Results At 6 months angiographic follow-up, BVS group had not inferior angiographic parameters but without statistically significant difference (p = 0.566). At 12 months follow-up, there was no difference at end points between the two groups (p = 0.476). No differences were found at angiographic or clinical follow-up between BVS and EES. Conclusion This study shows that 1st generation everolimus-eluting BVS is non-inferior to EES for CTO revascularization. Further studies are needed to clearly state which new smaller footprint BVS, faster reabsorption, magnesium-based less thrombogenicity, and advanced mechanical properties is under development. We cannot dismiss the efficacy and safety of new BVS technology. Trial registration ZU-IRB#2498/3-12-2016 Registered 3 December 2016, email: [email protected]


2017 ◽  
Vol 23 (6) ◽  
pp. 614-619 ◽  
Author(s):  
Jeremy J Heit ◽  
Nicholas A Telischak ◽  
Huy M Do ◽  
Robert L Dodd ◽  
Gary K Steinberg ◽  
...  

Background Subarachnoid hemorrhage (SAH) secondary to rupture of a blister aneurysm (BA) results in high morbidity and mortality. Endovascular treatment with the pipeline embolization device (PED) has been described as a new treatment strategy for these lesions. We present the first reported case of PED retraction and foreshortening after treatment of a ruptured internal carotid artery (ICA) BA. Case description A middle-aged patient presented with SAH secondary to ICA BA rupture. The patient was treated with telescoping PED placement across the BA. After 5 days from treatment, the patient developed a new SAH due to re-rupture of the BA. Digital subtraction angiography revealed an increase in caliber of the supraclinoid ICA with associated retraction and foreshortening of the PED that resulted in aneurysm uncovering and growth. Conclusions PED should be oversized during ruptured BA treatment to prevent device retraction and aneurysm regrowth. Frequent imaging follow up after BA treatment with PED is warranted to ensure aneurysm occlusion.