Impact of high blood pressure variability on the occurrence of acute type B aortic dissection

Vascular ◽  
2020 ◽  
Vol 28 (4) ◽  
pp. 413-420
Author(s):  
Chao Song ◽  
Guanyu Yu ◽  
Xiang Feng ◽  
Rui Feng ◽  
Junmin Bao ◽  
...  

Background Acute type B aortic dissection is a life-threatening medical emergency, and hypertension is believed to be an important predictor of aortic dissection; the impact of blood pressure variability on the onset and development of aortic dissection has attracted increasing attention. Methods A total of 120 acute type B aortic dissection patients and 57 hypertensive patients without aortic dissection were consecutively enrolled and retrospectively reviewed between January 2013 and November 2015. There were 60 acute type B aortic dissection patients in both high and low blood pressure variability groups. Results Blood pressure variability showed higher diagnostic value than hypertension in aortic dissection, and the best threshold of blood pressure variability is 5.71 mmHg. By performing multivariable logistic regression, we found that the history of hypertension was likely to be a risk factor of blood pressure variability (95% CI: 1.155–6.422, P = 0.022). Nine patients from high blood pressure variability group and two from low blood pressure variability group ( χ2 = 4.90, P = 0.027) received emergency surgery within 24 hours after admission. The presence of multiple tears (>2, 55.0% vs. 45.0%, P = 0.001), configuration of the false lumen (spiral false lumen) (50.0% vs. 21.7%, P = 0.001), the diameter of the false lumen (49.6 ± 15.0 mm vs. 37.6 ± 10.8 mm, P < 0.001), the false/true lumen ratio (1.53 ± 1.02 vs. 0.929 ± 0.733, P < 0.001), and the number of visceral arteries involved (1.75 ± 0.942 vs. 0.800 ± 0.927, P < 0.001) showed significant differences between high and low blood pressure variability groups. Nine (30%) patients from the high blood pressure variability group showed a maximum diameter of false lumen over 60 mm, while none was found in the low blood pressure variability group. Conclusions High blood pressure variability, the presence of multiple tears (>2), the configuration of false lumen, the diameter of the false lumen, false/true lumen ratio, and the number of visceral arteries involved were independent risk factors for acute type B aortic dissection.

2021 ◽  
pp. 153857442110451
Author(s):  
Masaki Kano ◽  
Toru Iwahashi ◽  
Toshiya Nishibe ◽  
Kentaro Kamiya ◽  
Hitoshi Ogino

We report 2 cases of successful thoracic endovascular aortic repair (TEVAR) for acute type B aortic dissection (ABAD) complicated with spinal cord ischemia (SCI). Case 1. A 70-year-old gentleman found with an uncomplicated ABAD with false lumen occluded, developed SCI shortly after admission during the initial medical management. Cerebrospinal fluid drainage (CSFD) was initiated followed by emergent TEVAR. SCI improved, and the patient was discharged. Case 2. A 52-year-old gentleman developed uncomplicated ABAD with patent false lumen. 5 hours after admission, he developed SCI during the initial medical management. Emergent TEVAR was performed followed by CSFD, and the SCI improved before discharge. These cases prompted us to address prompt TEVAR for primary entry closure and true lumen dilatation with postoperative hypertensive management to relieve the dynamic obstruction of the segmental arteries responsible for the compromised spinal cord circulation in complicated ABAD.


2020 ◽  
Vol 54 (8) ◽  
pp. 756-759
Author(s):  
Amer Harky ◽  
Robert K. Fisher ◽  
Mark L. Field

Purpose: To report a case who required a thoracic endovascular stenting (TEVAR) following the deployment of frozen elephant trunk due to false lumen expansion Case Report: A 47 years old male patient undergone emergency repair of acute type A aortic dissection in 2011 with bioprosthetic aortic root conduit. Seven years later he presented with moderate aortic valve disease and expanding chronic dissection of the aortic arch, therefore a redo operation with replacement of the prosthetic aortic valve, ascending aorta, total arch and deployment of frozen elephant trunk and he was discharged in good health. Several days post discharge he presented with new onset of chest pain and a new dissection involved the thoracoabdominal aorta was noted pressing on the true lumen and the frozen elephant trunk. Following a multi-disciplinary team meeting, TEVAR was deemed as a most appropriate approach and this was achieved successfully, and patient was discharged. At 1 year of follow up, he remains well and asymptomatic. Conclusion: Close imaging follow-up following deployment of a FET is mandatory. A new acute Type B aortic dissection distal to the FET, that causes false lumen propagation parallel to the stented portion, is a surgical emergency and further intervention mandated.


2019 ◽  
Vol 2019 ◽  
pp. 1-8
Author(s):  
Hao Zhang ◽  
Danying Zhang ◽  
Yudong Sun ◽  
Ye Lu ◽  
Jiaxuan Feng ◽  
...  

Objective. To explore a new treatment that can proceed from the whole, control blood pressure smoothly and coordinate the treatment of multiple factors causing blood pressure fluctuations. Method. We conducted a single-center, double-blinded, and randomized controlled clinical trial. 48 patients with acute Type B aortic dissection were randomly assigned into two groups: the experimental group, who received pinggan formula treatment, and the control group, who received placebo treatment. The drug was taken orally after meals three times a day. Only when the patients’ blood pressure fluctuated, conventional antihypertensive drugs were given to maintain the blood pressure within the target range and the dosage was recorded to convert the DDD value. Meanwhile, the international standardized score was used to evaluate the defecation, sleep, pain, anxiety, and depression of patients in the two groups during the hospitalization. Result. Univariate analysis was conducted on variables that might affect the assessment results, and it was found that grouping factors had a significant impact on the outcome variables, that is, after the intervention, the mean value of DDDs used in the perioperative period in the control group was 2.19 (0.38, 4.00). (P=0.0219), defecation score (2.13 (1.59, 2.67); P<0.0001), sleep score (0.95 (0.40, 1.50); P=0.0014), pain score (1.77 (0.61, 2.93); P=0.0045), depression score (4.04 (2.95, 5.12); and P<0.0001) were significantly higher than that of the experimental group, and the difference was statistically significant. Conclusion. Pinggan formula has a clear therapeutic regulation effect on the overall hemodynamics of acute Stanford type B aortic dissection during the perioperative period and can be recommended as an auxiliary drug for conventional antihypertensive drugs at the current stage.


2021 ◽  
Vol 12 ◽  
Author(s):  
Likun Sun ◽  
Jiehua Li ◽  
Lunchang Wang ◽  
Quanming Li ◽  
Hao He ◽  
...  

Background: Acute type B aortic dissection is a highly serious aortic pathology. Aortic geometric parameters may be useful variables related to the occurrence of acute type B aortic dissection (aTBAD). The aim of the study is to delineate the alteration in aortic geometric parameters and analyze the specific geometric factors associated with aTBAD.Methods: The propensity score matching method was applied to control confounding factors. The aortic diameter, length, angulation, tortuosity, and type of aortic arch of the aTBAD and control group were retrospectively analyzed via three-dimensional computed tomography imaging created by the 3mensio software (version 10.0, Maastricht, The Netherlands). The geometric variables of true lumen and false lumen in the descending aorta were measured to estimate the severity of aortic dissection. Multivariable logistic regression models were used to investigate the significant and specific factors associated with aTBAD occurrence. The area under the receiver operating characteristic curve (AUC) was used to estimate the performance of the model.Results: After propensity score matching, 168 matched pairs of patients were selected. The ascending aorta and aortic arch diameters were dilated, and the ascending aorta and total aorta lengths were elongated in aTBAD group significantly (P &lt; 0.001). The ascending aorta and aortic arch angulations in the aTBAD group were sharper than those of the controls (P = 0.01, P &lt; 0.001, respectively). The aortic arch and total aorta tortuosities were significantly higher in the aTBAD group (P = 0.001, P &lt; 0.001, respectively). There were more type III arch patients in the aTBAD group than the controls (67.9 vs. 22.6%). The true lumen angulation was sharper than that in the false lumen (P &lt; 0.01). The true lumen tortuosity was significantly lower than that in the false lumen (P &lt; 0.001). The multivariable models identified that aortic arch angulation, tortuosity, and type III arch were independent and specific geometric factors associated with aTBAD occurrence. The AUC of the multivariable models 1, 2, 3 were 0.945, 0.953, and 0.96, respectively.Conclusions: The sharper angulation and higher tortuosity of aortic arch and type III arch were the geometric factors associated with aTBAD in addition to the ascending aorta elongation and aortic arch dilation. The angulation and tortuosity of the true and false lumens may carry significant clinical implications for the treatment and prognosis of aTBAD.


Circulation ◽  
2000 ◽  
Vol 102 (suppl_3) ◽  
Author(s):  
Hiromu Terai ◽  
Nobushige Tamura ◽  
Tatsuo Nakamura ◽  
Kazunobu Nishimura ◽  
Norimasa Tsutsui ◽  
...  

Background —Despite recent progress in medical and surgical treatment, acute type B aortic dissection still carries a high mortality rate. We have developed a novel cylindrical balloon catheter for less invasive treatment to block the entry of the dissection and induce thrombotic occlusion of the false lumen. The balloon has the shape of a sheet when deflated but a double-cylinder shape when inflated. Therefore, aortic blood flow is maintained through the cylindrical lumen during balloon inflation. Methods and Results —Six beagle dogs underwent a left thoracotomy at the 6th intercostal space. An acute dissection of 4-cm length was created surgically on the descending aorta. The balloon catheter was inserted through the distal descending aorta and advanced to the entry site. The balloon catheter was inflated for 6 hours. The blood flow in the descending aorta and the position of the balloon was monitored by color Doppler echovasculography. Four dogs were killed humanely on the following day and 2 dogs 10 days after the surgery. The descending aorta was examined macroscopically and microscopically in all dogs. In all dogs, the false lumen was occluded by thrombi. Although no dog had clinical evidence of distal thromboembolism, 2 of the 4 dogs that were killed on the second postoperative day had fresh mural thrombi in the true lumen. Conclusions —The false lumen of the acute type B aortic dissection was effectively occluded by the novel cylindrical balloon catheter in the canine experimental model. The thrombus formation in the true lumen is the problem to be solved.


2007 ◽  
Vol 83 (3) ◽  
pp. 1059-1066 ◽  
Author(s):  
Maria Schoder ◽  
Martin Czerny ◽  
Manfred Cejna ◽  
Thomas Rand ◽  
Alfred Stadler ◽  
...  

2016 ◽  
Vol 102 (6) ◽  
pp. 1925-1932 ◽  
Author(s):  
Apoorva Girish ◽  
Muralidhar Padala ◽  
Kanika Kalra ◽  
Bryant V. McIver ◽  
Ravi K. Veeraswamy ◽  
...  

2007 ◽  
Vol 357 (4) ◽  
pp. 349-359 ◽  
Author(s):  
Thomas T. Tsai ◽  
Arturo Evangelista ◽  
Christoph A. Nienaber ◽  
Truls Myrmel ◽  
Gabriel Meinhardt ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document