scholarly journals Should the Glidescope video laryngoscope be used first line for all oral intubations or only in those with a difficult airway? A review of current literature

2018 ◽  
Vol 28 (12) ◽  
pp. 322-333 ◽  
Author(s):  
Terrie-Marie Russell ◽  
Anil Hormis ◽  

The purpose of this study was to review literature that looked into the efficacy of the Glidescope video laryngoscope versus the Macintosh laryngoscope in oral endotracheal intubations. We aimed to answer the question ‘Should the Glidescope video laryngoscope laryngoscopes be used as first line intubation aids or only in the difficult airway?’ A systematic search of electronic databases was made. The inclusion criteria included: Glidescope, video laryngoscope, and Macintosh laryngoscope in human studies. The study aimed to compare first attempt success rate, glottic view and intubation time in papers dating between 2009 and 2017. Eleven trials with a total of 7,919 patients with both difficult and normal airways were included. The trials showed an improvement in first attempt success rate and glottic view with the Glidescope video laryngoscope especially in those with difficult airways. Overall time to intubate showed no significant differences between the Glidescope video laryngoscope and the Macintosh laryngoscope although it was identified that with increased training and experience with the Glidescope video laryngoscope, intubation time was reduced. Glidescope video laryngoscopes show advantages over the Macintosh laryngoscopes in obtaining better glottic views in those with difficult airways. However its use is not supported in all routine intubations.

2021 ◽  
Vol 44 (1) ◽  
pp. 21-28
Author(s):  
Phatthranit Phattharapornjaroen ◽  
Promphet Nuanprom ◽  
Prayoot Suk-um ◽  
Manina Thilarak ◽  
Chaiyaporn Yuksen

Background: Trauma patients who entrapped in the accident vehicle are predispose to have cervical spine injuries and they needed to be intubated with face-to-face intubation technique using Macintosh laryngoscope. Nowadays, video laryngoscope has been introduced to improve the intubation technique. Objective: To compare the effectiveness of video laryngoscope and Macintosh laryngoscope for face-to-face intubation in sitting manikin model with limitation of neck motion. Methods: The study was performed in a randomized experimental study. Subjects were divided into 2 groups both did face-to-face intubation using video laryngoscope and Macintosh laryngoscope in a sitting manikin model with limitation of neck motion. The success rate of intubation, time to finish intubation, and vocal cord visualization were analyzed. Results: Of 41 subjects including 2nd and 3rd year paramedic students, 21 subjects went to video laryngoscope group, and 20 subjects went to Macintosh laryngoscopes group. The Macintosh laryngoscope intubation technique showed significantly better success rate compared to video laryngoscope (100% and 25%, P < .001). In addition, intubation time of Macintosh laryngoscope was significantly less than video laryngoscope (mean [SD], 27 [24.7] and 75 [66.3] seconds, P < .001). However, vocal cord visualization from both laryngoscope techniques showed no statistically significant (P = .08). Conclusions: Intubation training of Macintosh laryngoscope for in sitting model with neck motion limitation showed better success rate and less time than video laryngoscope, with the same vocal cord visualization.  


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Sanghyun Lee ◽  
Wonhee Kim ◽  
Hyunggoo Kang ◽  
Jaehoon Oh ◽  
Tae Ho Lim ◽  
...  

Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15° and 30° left lateral tilt.Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation.Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (allP<0.05), whereas there was no significant difference between the two video laryngoscopes (in 15° tilt,P=1; in 30° tilt,P=0.71). The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (allP<0.001). Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes.Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate.


2020 ◽  
Author(s):  
Toshiyuki Nakanishi ◽  
Yoshiki Sento ◽  
Yuji Kamimura ◽  
Kazuya Sobue

Abstract Background: The aerosol box was designed to prevent cough droplets from spreading, but it can impede tracheal intubation. We tested the hypothesis that the C-MAC® video laryngoscope (C-MAC) with an external display is more useful than the i-view™ video laryngoscope (i-view) with an integrated display, or a Macintosh direct laryngoscope (Macintosh) for tracheal intubation with an aerosol box.Methods: This prospective, randomized, crossover simulation study was conducted at an operating room of the two hospitals (a university hospital and a tertiary teaching hospital). We recruited 37 medical personnel (36 anesthesiologists and 1 dental anesthesiologist) who were working in the fields of anesthesia and intensive care with > 2 years of dedicated anesthesia experience from five hospitals. We divided the participants into six groups to use the laryngoscope in a determined order. After the training using each laryngoscope without a box, the participants performed tracheal intubation thrice with each laryngoscope with at least two-hour intervals. The primary outcome was the intubation time. The secondary outcomes were the success rate, Cormack-Lehane grade, and subjective difficulty scale score (numeric rating scale 0–10, 0: no difficulty, 10: highest difficulty). We used the Friedman test and the Wilcoxon signed-rank test with Bonferroni adjustment. Data are shown as median [interquartile range].Results: Thirty-seven personnel (11 women and 26 men) with 12 [5–19] (median [interquartile range]) years of anesthesia and intensive care experience were enrolled. There was no significant difference in the intubation time: 30 [26–32] s for Macintosh, 29 [26–32] s for i-view, and 29 [25–31] s for C-MAC (P=0.247). The success rate was 95%–100% without significant difference (P=0.135). The i-view and C-MAC video laryngoscopes exhibited superior Cormack-Lehane grades and lower subjective difficulty scale scores than the Macintosh laryngoscope; however, there were no differences between the i-view and C-MAC video laryngoscopes.Conclusions: Rapid and highly successful tracheal intubation was possible with Macintosh laryngoscope, i-view, and C-MAC video laryngoscopes on a manikin with an aerosol box. Improved Cormack-Lehane grade and ease of procedure may support the use of video laryngoscopes.Trial registration: UMIN Clinical Trials Registry, identifier UMIN000040269.


2018 ◽  
Author(s):  
LEYLA KILINÇ ◽  
HACER SEBNEM TURK ◽  
SURHAN CINAR ◽  
CANAN TÜLAY ISIL ◽  
MELTEM KABA

Abstract Background: We compared intubation conditions, intubation times, and hemodynamic response with the GlideScope video laryngoscope or the Macintosh direct laryngoscope in children older than one year. Methods: In total, 80 patients aged 1–12 years, scheduled to undergo elective surgery under general anesthesia with endotracheal intubation were included in a prospective, randomized trial.After standard anesthesia induction, patients were randomized into two groups.The group G patients(n = 40) were intubated with the GlideScope and the group M patients(n = 40) were intubated with the Macintosh laryngoscope.Intubation time, number of attempts,Cormack–Lehane score, airway maneuvers,visual analog score were recorded. Hemodynamic variables were recorded before and after anesthesia induction, at intubation, and one,three, and five minutes after intubation. Results: The demographic data and operation time were similar between the two groups. The intubation time was longer in Group G. The incidence of Cormack–Lehane score 1 was higher in Group G and that of Cormack–Lehane score 2 was higher in Group M. The hemodynamic parameters were similar between the two groups. Conclusion: We concluded that the GlideScope video laryngoscope provided better glottis visualization, but prolonged intubation time. No beneficial hemodynamic effect was found with the video laryngoscope. Keywords: Macintosh Laryngoscope, Orotracheal Intubation, Videolaringoscope, Pediatric Trial registration: ClinicalTrial.gov, NCT03326882, retrospectively registered, October 31, 2017


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Hyun Young Choi ◽  
Young Min Oh ◽  
Gu Hyun Kang ◽  
Hyunggoo Kang ◽  
Yong Soo Jang ◽  
...  

Objectives. Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)).Method. Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications.Result. VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes.Conclusion. AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation.


2017 ◽  
Vol 24 (5) ◽  
pp. 237-243 ◽  
Author(s):  
Sanghyun Lee ◽  
Hyunggoo Kang ◽  
Jaehoon Oh ◽  
Tae Ho Lim ◽  
Yoonjae Lee ◽  
...  

Introduction: Prehospital tracheal intubation of a difficult airway is challenging for paramedics. Thus far, the potential role of video laryngoscopes for this purpose has not been confirmed. Therefore, this study aimed to determine the impact of different types of video laryngoscopes on the success rate and time to intubation by paramedics. Methods: This is a prospective, randomized, crossover manikin study involving 18 paramedics. Participants performed intubation on a difficult airway in a high-fidelity manikin using Pentax-AWS®, Glidescope®, and King Vision® (with two blade types). Time to intubation and success rate of intubation were determined. Participants also rated the best glottic view and reported their preferences of devices. Results: In a difficult-airway scenario, the median time to intubation with Pentax-AWS® was 22.9 s (interquartile range, 19.5–24.9 s), which was significantly shorter than using other devices. There were no significant differences in the time to maximal exposure of the vocal cords between four devices ( p = 0.156). The time to insert the endotracheal tube with Pentax-AWS® and King Vision® with a guide-channel blade was significantly shorter than that with the other two devices (all, p < 0.05). Pentax-AWS® and King Vision® with a guide-channel blade showed higher success rates than the other two devices ( p = 0.04). With regard to device preference, 14 participants preferred Pentax-AWS® among all devices analyzed. Conclusion: Pentax-AWS® could be an appropriate device for paramedics in cases of difficult airways, with high success rate.


2020 ◽  
Vol 35 (1) ◽  
pp. 47-53
Author(s):  
Minhazur Rahman Chowdhury ◽  
Muhammad Abdul Quaium Chowdhury ◽  
Jitu Das Gupta ◽  
Subir Barua ◽  
Mohammad Abdul Mannan ◽  
...  

Background: Endotracheal intubation is an essential primary skill for all anesthesiologists. For cardiac anesthesiologists rapid and proper intubation is more important as failure may cause serious consequences. Video laryngoscope provides a better real time view of the larynx, epiglottis and vocal cords. It also keeps the intubating anesthetist away from the patient as compared to conventional laryngoscopy. This may be very important in this COVID-19 era. To the best of our knowledge the Department of Cardiac Surgery and Cardiac Anesthesia of Chattogram Medical College & Hospital is the first center in Bangladesh to introduce video laryngoscope in cardiac OT. The objective of this study was aimed to compare the intubation time, hemodynamic response to laryngoscopy, success rates and operator’s comfort using the conventional Macintosh laryngoscope and video laryngoscope in adult patients undergoing cardiac surgery. Materials and Methods: A total of 60 adult patients were included in this comparative study, subjected to general anesthesia for cardiac surgery, intubated using either conventional Macintosh direct laryngoscope or video laryngoscope. Patients were intubated by 3 different consultant anesthesiologists with equal competency of our department. Results: There was not much difference between Video laryngoscopy and conventional laryngoscopy in terms of intubation time and success rate. Video laryngoscopy exhibited less hemodynamic response to laryngoscopy and intubation; however, the difference was not statistically significant in this small group of patients. Operators were much more comfortable with Video laryngoscope than conventional laryngoscope particularly with the cases of difficult intubation because of the better glottic view with the former. Conclusion: Video laryngoscope is preferred by cardiac anesthetists because of better glottic view. Bangladesh Heart Journal 2020; 35(1) : 47-53


2019 ◽  
Vol 2019 ◽  
pp. 1-7
Author(s):  
Togay Evrin ◽  
Jacek Smereka ◽  
Damian Gorczyca ◽  
Szymon Bialka ◽  
Jerzy Robert Ladny ◽  
...  

Introduction. Airway management is one of key elements of resuscitation. Endotracheal intubation is still considered the gold standard for airway management during resuscitation. Aim. The aim of the study was to compare success rates and intubation time of different endotracheal intubation methods during emergency intubation with difficult airways in the conditions of cardiopulmonary resuscitation in a standardized manikin model. Methods. The study was designed as a prospective, randomized, cross-over simulation study. It involved 46 paramedics with at least 5 years of experience in Emergency Medical Service. The participants performed endotracheal intubation under difficult airway conditions during continuous chest compression, implemented with the LUCAS3 chest compression system. Three methods of tracheal intubation were applied: (1) standard Macintosh laryngoscope without a bougie stylet; (2) standard laryngoscope and a standard bougie stylet; (3) standard laryngoscope and a new bougie stylet. Results. The overall intubation success rate was 100% in the standard bougie and new bougie groups and lower (86.9%) when no bougie stylet was used (P=0.028). The intubation success rate with the 1st attempt equalled 91.3% for the new bougie group, 73.9% for standard bougie, and only 23.9% in the no-bougie group. The median intubation time was shortest in the new bougie group, where it amounted to 29 s (interquartile range [IQR]: 25–38); the time equalled 38s (IQR:31–44.5) in the standard bougie group and 47.5s (IQR:36–58) in the no-bougie group. The ease of use was lowest in the no-bougie group (85, IQR:63–88), average in the standard bougie group (44, IQR:30–51), and highest in the new bougie stylet group (32, IQR:19–41). Conclusion. In this manikin-based study, paramedics were able to perform endotracheal intubation with higher efficacy and in a shorter time using the new bougie stylet as compared with the standard bougie stylet.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Toshiyuki Nakanishi ◽  
Yoshiki Sento ◽  
Yuji Kamimura ◽  
Kazuya Sobue

Abstract Background We tested the hypothesis that the C-MAC® video laryngoscope (C-MAC) with an external display is more useful than the disposable i-view™ video laryngoscope (i-view) with an integrated display or a Macintosh direct laryngoscope (Macintosh) for tracheal intubation with an aerosol box. Methods In this randomized, crossover manikin study, we recruited 37 medical personnel with > 2 years of dedicated anesthesia experience from five hospitals. After the three successful intubations within 60 s using each laryngoscope without a box, the participants performed tracheal intubation thrice with each laryngoscope with at least 2-h intervals in a determined order. The primary outcome was the intubation time. The secondary outcomes were success rate, Cormack-Lehane grade, and subjective difficulty scale score. Results Thirty-seven personnel (11 women and 26 men) with 12 [5–19] (median [interquartile range]) years of anesthesia and intensive care experience were enrolled. There was no significant difference in the intubation time: 30 [26–32] s for Macintosh, 29 [26–32] s for i-view, and 29 [25–31] s for C-MAC (P = 0.247). The success rate was 95–100%, without a significant difference (P = 0.135). The i-view and C-MAC exhibited superior Cormack-Lehane grades and lower subjective difficulty scale scores than the Macintosh; however, there were no differences between the i-view and C-MAC. Conclusions Rapid and highly successful tracheal intubation was possible with both Macintosh, i-view, and C-MAC on a normal airway manikin in an aerosol box. Improved Cormack-Lehane grade and the ease of performing the procedure may support the use of video laryngoscopes. Trial registration UMIN Clinical Trials Registry, UMIN000040269. Registered 30 April 2020.


2015 ◽  
Vol 2015 ◽  
pp. 1-4
Author(s):  
Prerana N. Shah ◽  
Kaveri Das

Background. Video laryngoscopes provide better view and can improve ease of intubation compared with standard laryngoscopes. Methods. A prospective randomized study was done on 60 patients, 18 to 65 years old, comparing McGrath video laryngoscope and Macintosh laryngoscope. The aim was to compare the ease, efficacy, and usability of them during routine airway management. The primary endpoint was duration of intubation and the secondary endpoints were Cormack and Lehane grade of laryngoscopic view, number of intubation attempts, and incidence of complications. Results. There was an increase in total duration of intubation with McGrath video laryngoscope with 42.9 ± 19.5 seconds compared to Macintosh laryngoscope with 17.9 ± 4.6 seconds. In Macintosh group, 73.3% had grade I, 20% had grade II, and 6.7% had grade III Cormack Lehane view, while in McGrath group, 83.3% had grade I, 13.3% had grade II, and 3.3% had grade III. In McGrath group, 6 patients (20%) required more than 120 seconds to get intubated and only 73.3% were intubated in 1 attempt, while patients in Macintosh group had 100% successful intubation in 1 attempt. Pharyngeal trauma was seen with McGrath videolaryngoscopy. Conclusion. Duration of laryngoscopy, intubation, and total duration of intubation were significantly higher in McGrath group than in Macintosh group. McGrath group required a higher number of intubation attempts.


Sign in / Sign up

Export Citation Format

Share Document