scholarly journals Early outcomes of augmented glenoid components in anatomic total shoulder arthroplasty: a systematic review

2021 ◽  
pp. 175857322110329
Author(s):  
Ujash Sheth ◽  
James YJ Lee ◽  
Diane Nam ◽  
Patrick Henry

Background The objective was to evaluate the short-term clinical and radiological outcomes following augmented anatomic total shoulder arthroplasty in patients with posterior glenoid deficiency. Methods An electronic search of EMBASE, MEDLINE, and PubMed identified studies reporting clinical and radiographic outcomes following augmented anatomic total shoulder arthroplasty among patients with posterior glenoid deficiency. Results Nine studies including 312 shoulders underwent anatomic total shoulder arthroplasty using an augmented glenoid implant between 2015 and 2020. A statistically significant improvement in range of motion (ROM), visual analog scale (VAS), American Shoulder & Elbow Surgeons (ASES), Constant, University of California - Los Angeles and Simple Shoulder Test (SST) scores was demonstrated at mean follow-up of 37.1 months. Glenoid retroversion improved from 21.8° to 9.5°. At final follow-up, radiolucency was reported in 35.1% of shoulders. The 16° full-wedge augment led to higher and more severe radiographic lucency, while high peg perforation rates (44%) were observed among 5-mm augment stepped implants. The overall rate of complication was 2.6%. Rate of revision surgery was 1.9%. Conclusions Overall, early- to mid-term outcomes following augmented anatomic total shoulder arthroplasty for posterior glenoid deficiency demonstrate good to excellent overall clinical results. More radiographic and clinical failures were reported in larger full wedge (16°) augments and stepped augments (5 mm). Prospective studies examining mid- and long-term outcomes will help further elucidate safety and efficacy of these relatively new implants.

2021 ◽  
pp. 155633162110408
Author(s):  
Ahmed Haleem ◽  
Phelopater Sedrak ◽  
Chetan Gohal ◽  
George S. Athwal ◽  
Moin Khan ◽  
...  

Background: Hybrid glenoid components in total shoulder arthroplasty (TSA) utilize both polyethylene and metal components to provide short-term stability and long-term biologic fixation through bone ingrowth. Questions/Purpose: We sought to systematically review the literature for studies that assessed outcomes of TSA performed using hybrid glenoid components. Methods: PubMed, Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Embase were searched systematically for articles measuring clinical and patient-reported outcomes and rates of complication and revision following TSA using a hybrid glenoid component. Results: Seven studies with 593 shoulders were included in this review. The mean age of patients was 65 ± 1 years, and 46% of the population was male. Mean follow-up was 50 months (4.2 years). The overall complication rate was 7% and rate of revision was 2.5%; glenoid radiolucency was present in 33% of shoulders at mean follow-up of 50 months. Mean improvements in forward elevation, external rotation, internal rotation score, and abduction were 49°, 28°, 2 points, and 42°, respectively. Mean improvements in Constant, American Shoulder and Elbow Surgeons (ASES), and University of California, Los Angeles (UCLA) scores were 36 points, 52 points, and 17 points, respectively. Conclusion: Our review found that TSA using hybrid glenoid components results in low rates of complication and revision at early follow-up. Long-term studies are warranted to understand more fully the role of hybrid glenoid components in TSA.


2021 ◽  
Vol 24 (3) ◽  
pp. 125-134
Author(s):  
Kirtan Tankshali ◽  
Dong-Whan Suh ◽  
Jong-Hun Ji ◽  
Chang-Yeon Kim

Background: To evaluate clinical and radiological outcomes of bony increased offset-reverse total shoulder arthroplasty (BIO-RSA) in the Asian population at mid-term follow-up.Methods: From June 2012 to August 2017 at a single center, 43 patients underwent BIO-RSA, and 38 patients with a minimum of 2 years of follow-up were enrolled. We evaluated the preoperative and postoperative clinical outcomes, radiological outcomes (notching and loosening), and complications of BIO-RSA at the last follow-up. In addition, we divided these patients into notching and not-notching groups and compared the demographics, preoperative, and postoperative characteristics of patients between the two groups.Results: Visual analog scale, American Shoulder and Elbow Surgeons, University of California-Los Angeles, and Simple Shoulder Test scores improved significantly from preoperative (average: 5, 39.43, 16.22, 3.94) to postoperative (average: 1.71, 78.91, 28.34, 7.8; p<0.05) outcomes. All range of motion except internal rotation improved significantly at the final follow-up (p<0.05), and the bone graft was well-incorporated with the native glenoid in all patients (100%). However, scapular notching was observed in 20/38 patients (53%). In the comparison between notching and not-notching groups (18 vs. 20 patients), there were no significant differences in demographics, radiological parameters, and clinical outcomes except acromion-greater tuberosity (AT) distance (p=0.003). Intraoperative complications were three metaphyseal fractures and one inferior screw malposition. Postoperative complications included one heterotopic ossification, one scapula neck stress fracture, one humeral stem loosening, and one late infection.Conclusions: BIO-RSA resulted in improved clinical outcomes at mid-term follow-up in the Asian population. Although better cosmesis and advantages of glenoid lateralization were observed, we observed higher rates of scapular notching compared to previously reported rates in BIO-RSA studies. In addition, adequate glenoid lateralization with appropriate humeral lengthening (AT distance) might reduce scapular notching.


Author(s):  
Sascha Beck ◽  
Theodor Patsalis ◽  
André Busch ◽  
Florian Dittrich ◽  
Alexander Wegner ◽  
...  

Abstract Introduction Stemmed humeral implants have represented the gold standard in total shoulder arthroplasty (TSA) for decades. Like many other joints, the latest trends in TSA designs aim at bone preservation. Current studies have demonstrated that native proximal humeral bone stresses are most closely mimicked by stemless implants. Nevertheless, there are concerns about the long-term performance of stemless designs. The aim of the present study was to evaluate the long-term radiographic changes at the proximal humerus in anatomical stemless press-fit TSA. Materials and Methods Between 2008 and 2010, 48 shoulders in 43 patients were resurfaced using an anatomic stemless shoulder prosthesis (TESS, Biomet). Thirty shoulders in twenty-five patients who were aged 65.7 ± 9.9 (34 to 82) years were available for clinical and radiographic review at a mean follow-up of 94.0 ± 8.9 (78 to 110) months. Results Radiographic changes of the proximal humerus due to stress shielding were found in 38.4% of the stemless TESS implants. Mild stress shielding accounted for 80% of the observed radiographic changes. Radiographs exhibited stable fixation of the stemless humeral press-fit implant at early and late follow-up. In contrast, radiolucent lines at the glenoid implant were found in 96.1% of the cases. Irrespective of the degree of radiographic changes, clinical scores (VAS, Quick-DASH, Constant score) significantly improved at follow-up. Conclusions The anatomic stemless press-fit implant seems to be favorable in terms of implant-related stress shielding. Clinical outcome was not affected by radiographic changes, demonstrating an 8-year clinical performance that seems to be comparable to conventional stemmed TSA.


2013 ◽  
Vol 22 (4) ◽  
pp. e31
Author(s):  
Edwin R. Cadet ◽  
Peter Kok ◽  
R. Michael Greiwe ◽  
Christopher S. Ahmad ◽  
William N. Levine ◽  
...  

2017 ◽  
Vol 11 (1) ◽  
pp. 26-34 ◽  
Author(s):  
Robert S. J. Elliott ◽  
Yi-Jia Lim ◽  
Jennifer Coghlan ◽  
John Troupis ◽  
Simon Bell

Background There are few studies reporting long-term rotator cuff integrity following repair. The present study reports a case series of surgically repaired supraspinatus tendons followed up with clinical outcomes and ultrasound imaging after an average of 16 years. Methods The prospectively studied clinical outcomes at short-, medium- and long-term follow-up in 27 shoulders in 25 patients treated with arthroscopic subacromial decompression and mini-open rotator cuff repair have been reported previously. The functional outcomes scores recorded were the University of California Los Angeles (UCLA), American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) measures. These patients then underwent an ultrasound scan with respect to the long-term assessment of the shoulder and the integrity of the repair. Results A recurrent tear was noted in 37% of patients at 16.25 years after surgery, of which 50% were small. Two patients required repeat surgery. Patients had a mean UCLA score of 30, an ASES score of 91.3 and a SST score of 9.5 with a 85% level of satisfaction with surgery. Patients with a recurrent tear had outcome scores equivalent to those with an intact cuff with no significant pain. No independent risk factors were identified as predictors for recurrent tear. Conclusions Patients showed sustained benefit and satisfaction at long-term follow-up despite a 37% recurrence of full-thickness supraspinatus tear.


2018 ◽  
Vol 26 (2) ◽  
pp. 230949901876857 ◽  
Author(s):  
Eduard Alentorn-Geli ◽  
Nathan R Wanderman ◽  
Andrew T Assenmacher ◽  
John W Sperling ◽  
Robert H Cofield ◽  
...  

Purpose: To compare the outcomes of total shoulder arthroplasty (TSA) with posterior capsule plication (PCP) and reverse shoulder arthroplasty (RSA) in patients with primary osteoarthritis, posterior subluxation, and bone loss (Walch B2). Patients and methods: All shoulders undergoing anatomic TSA with PCP were retrospectively identified (group 1, G1) and compared to shoulders undergoing RSA (group 2, G2) for Walch B2 osteoarthritis. There were 15 patients in G1 (mean (SD) age and follow-up of 70.5 (7.5) years and 42.8 (18.4) months, respectively) and 16 patients in G2 (mean (SD) age and follow-up of 72.6 (5.4) years and 35.1 (14.2) months, respectively). Results: Both groups had substantial improvements in pain and function. In G1, results were excellent in 80% and satisfactory in 20%, compared to 81% and 6% in G2, respectively ( p = 0.2). The mean (SD) American Shoulder and Elbow Surgeons score was 91.2 (6.7) and 80.3 (14.3) in G1 and G2, respectively ( p = 0.08). The mean Simple Shoulder Test score was 10.6 in G1 and 8.5 in G2 ( p = 0.01). There were no reoperations in either group, but G1 had seven postoperative complications. Conclusions: The outcomes of TSA with PCP are comparable to RSA in patients with osteoarthritis and biconcave glenoids. However, TSA leads to more complications while RSA leads to lower functional outcomes.


2019 ◽  
Vol 12 (5) ◽  
pp. 330-337
Author(s):  
Lindsay Flynn ◽  
Matthew R Patrick ◽  
Christopher Roche ◽  
Joseph D Zuckerman ◽  
Pierre-Henri Flurin ◽  
...  

Background No studies compare outcomes of anatomic total shoulder arthroplasty to reverse total shoulder arthroplasty with more than five-year follow-up. Methods A multicenter prospectively collected shoulder registry was utilized to review all patients undergoing primary anatomic total shoulder arthroplasty or primary reverse total shoulder arthroplasty with a minimum five-year follow-up utilizing a single platform stem implant system. One-hundred-ninety-one patients received an anatomic total shoulder arthroplasty and 139 patients received a reverse total shoulder arthroplasty. Patients were scored preoperatively and at latest follow-up using the simple shoulder test (SST), University of California Los Angeles (UCLA), American shoulder and elbow surgeons (ASES), Constant, and shoulder pain and disability index (SADI) scores as well as range of motion. Radiographs were evaluated for implant loosening or notching. Complications were reviewed. A Student’s two-tailed, unpaired t-test identified differences in preoperative, postoperative, and pre-to-postoperative improvements. Results Reverse total shoulder arthroplasty patients were significantly older than anatomic total shoulder arthroplasty patients. All patients demonstrated significant improvement in functional metric scores and range of motion following anatomic total shoulder arthroplasty or reverse total shoulder arthroplasty. There was no difference in final outcome scores between anatomic total shoulder arthroplasty and reverse total shoulder arthroplasty patients at midterm follow-up; however, reverse total shoulder arthroplasty patients demonstrated significantly less motion. Discussion We demonstrate equivalent outcomes with five scoring metrics at mean follow-up of 71.3 ± 14.1 months. Although postoperative scores were significantly greater than preoperative scores for both anatomic total shoulder arthroplasty and reverse total shoulder arthroplasty patients, significant differences in outcome scores between cohorts were not observed.


Sign in / Sign up

Export Citation Format

Share Document