Layer manufactured production tooling incorporating conformal heating channels for transfer moulding of elastomer compounds

2001 ◽  
Vol 30 (8) ◽  
pp. 384-388 ◽  
Author(s):  
K.W. Dalgarno ◽  
T.D. Stewart ◽  
J.M. Allport
2012 ◽  
Vol 43 (2) ◽  
pp. 819-824 ◽  
Author(s):  
Geneviève Palardy ◽  
Pascal Hubert ◽  
Eduardo Ruiz ◽  
Mohsan Haider ◽  
Larry Lessard

2010 ◽  
Vol 160-162 ◽  
pp. 1211-1216
Author(s):  
Zhuang Liu ◽  
Xiao Qing Wu

The impregnation stage of the Resin Transfer Moulding process can be simulated by solving the Darcy equations on a mould model, with a ‘macro-scale’ finite element method. For every element, a local ‘meso-scale’ permeability must be determined, taking into account the local deformation of the textile reinforcement. This paper demonstrates that the meso-scale permeability can be computed efficiently and accurately by using meso-scale simulation tools. We discuss the speed and accuracy requirements dictated by the macro-scale simulations. We show that these requirements can be achieved for two meso-scale simulators, coupled with a geometrical textile reinforcement modeller. The first solver is based on a finite difference discretisation of the Stokes equations, the second uses an approximate model, based on a 2D simulation of the flow.


Polymer ◽  
1960 ◽  
Vol 1 ◽  
pp. 123-124
Author(s):  
J.M.J. Estevez
Keyword(s):  

2010 ◽  
Author(s):  
J Summerscales ◽  
◽  
C Hoppins ◽  
P Anstice ◽  
N Brooks ◽  
...  

Cancers ◽  
2019 ◽  
Vol 11 (11) ◽  
pp. 1709 ◽  
Author(s):  
Curto ◽  
Aklan ◽  
Mulder ◽  
Mils ◽  
Schmidt ◽  
...  

Clinical outcome of hyperthermia depends on the achieved target temperature, therefore target conformal heating is essential. Currently, invasive temperature probe measurements are the gold standard for temperature monitoring, however, they only provide limited sparse data. In contrast, magnetic resonance thermometry (MRT) provides unique capabilities to non-invasively measure the 3D-temperature. This study investigates MRT accuracy for MR-hyperthermia hybrid systems located at five European institutions while heating a centric or eccentric target in anthropomorphic phantoms with pelvic and spine structures. Scatter plots, root mean square error (RMSE) and Bland–Altman analysis were used to quantify accuracy of MRT compared to high resistance thermistor probe measurements. For all institutions, a linear relation between MRT and thermistor probes measurements was found with R2 (mean ± standard deviation) of 0.97 ± 0.03 and 0.97 ± 0.02, respectively for centric and eccentric heating targets. The RMSE was found to be 0.52 ± 0.31 °C and 0.30 ± 0.20 °C, respectively. The Bland-Altman evaluation showed a mean difference of 0.46 ± 0.20 °C and 0.13 ± 0.08 °C, respectively. This first multi-institutional evaluation of MR-hyperthermia hybrid systems indicates comparable device performance and good agreement between MRT and thermistor probes measurements. This forms the basis to standardize treatments in multi-institution studies of MR-guided hyperthermia and to elucidate thermal dose-effect relations.


Sign in / Sign up

Export Citation Format

Share Document