Performance of different low-flow oxygen delivery systems

Author(s):  
William Poncin ◽  
Grégory Reychler ◽  
Christophe De Terwangne ◽  
Matthieu Marnette ◽  
Frédéric Duprez
Stroke ◽  
2005 ◽  
Vol 36 (10) ◽  
pp. 2066-2067 ◽  
Author(s):  
Ritesh Agarwal ◽  
Dheeraj Gupta

1989 ◽  
Vol 25 (6) ◽  
pp. 370-371
Author(s):  
G. R. WILLIAMS ◽  
I. B. MASTERS ◽  
M. A. HARRIS

Breathe ◽  
2019 ◽  
Vol 15 (3) ◽  
pp. e108-e116
Author(s):  
Georgia Hardavella ◽  
Ioannis Karampinis ◽  
Armin Frille ◽  
Katherina Sreter ◽  
Ilona Rousalova

Oxygen use has extended from inpatient to outpatient settings for patients with chronic pulmonary diseases and complications of hypoxaemia. This article presents an overview of oxygen devices (oxygen concentrators, compressed gas cylinders and liquid oxygen) and delivery systems (high- and low-flow). The indications, advantages and disadvantages of each device and delivery system are presented, aiming to offer updated knowledge to the multidisciplinary team members managing patients with respiratory failure, and therefore allowing appropriate selection of devices and delivery systems that are tailored to the needs of each patient.


BMJ Open ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. e037964
Author(s):  
Shahan Waheed ◽  
Nazir Najeeb Kapadia ◽  
Muhammad Faisal Khan ◽  
Salima Mansoor Kerai ◽  
Ahmed Raheem ◽  
...  

IntroductionApnoeic oxygenation is a process of delivering continuous oxygen through nasal cannula during direct laryngoscopy. The oxygen that is delivered through these nasal cannulas is either low flow or high flow. Although the effectiveness of apnoeic oxygenation has been shown through systematic reviews and randomised controlled trials, a comparison of high-flow versus low-flow oxygen delivery has not been tested through a superiority study design. In this study we propose to assess the effectiveness of giving low-flow oxygen with head side elevation versus high-flow oxygen with head side elevation against the usual practice of care in which no oxygen is provided during direct laryngoscopy.Methods and analysisThis will be a three-arm study instituting a block randomisation technique with a sample size of 46 in each arm (see table 1). Due to the nature of the intervention, no blinding will be introduced. The primary outcomes will be lowest non-invasive oxygen saturation measurement during direct laryngoscopy and during the 2 min after the placement of the tube and the first pass success rate. The intervention constitutes head side elevation up to 30° for improving glottis visualisation together with low-flow or high-flow oxygen delivery through nasal cannula to increase safe apnoea time for participants undergoing endotracheal intubation. Primary analysis will be intention to treat.Ethics and disseminationThe study is approved by the Ethical Review Committee of Aga Khan University Hospital (2019-0726-2463). The project is an institution University Research Committee grant recipient 192 002ER-PK. The results of the study will be disseminated among participants, patient communities and healthcare professionals in the institution through seminars, presentations and emails. Further, the findings will be published in a highly accessed peer-reviewed medical journal and will be presented at both national and international conferences.Trial registration numberClinicalTrials.gov Registry (NCT04242537).


Anaesthesia ◽  
1991 ◽  
Vol 46 (2) ◽  
pp. 135-138 ◽  
Author(s):  
J.E. Fairfield ◽  
T. Goroszeniuk ◽  
A.M. Tully ◽  
A.P. Adams

Sign in / Sign up

Export Citation Format

Share Document