scholarly journals A comparison of cardiac motion analysis software packages: application to left ventricular deformation analysis in healthy subjects

Author(s):  
Haifa M Almutairi ◽  
Mohammed Y Khanji ◽  
Redha Boubertakh ◽  
Marc E Miquel ◽  
Steffen E Petersen
2016 ◽  
Vol 32 (12) ◽  
pp. 1697-1705 ◽  
Author(s):  
Flavio D’Ascenzi ◽  
Marco Solari ◽  
Michele Mazzolai ◽  
Matteo Cameli ◽  
Matteo Lisi ◽  
...  

Author(s):  
Si Yong Yeo ◽  
Xulei Yang ◽  
Like Gobeawan ◽  
Soo Kng Teo ◽  
Liang Zhong ◽  
...  

Animals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1242
Author(s):  
Georg Haider ◽  
Ursula Schulz ◽  
Nikola Katic ◽  
Christian Peham ◽  
Gilles Dupré

Single-port access systems (SPASs) are currently used in human and veterinary surgeries. However, they pose technical challenges, such as instrument crowding, intra- and extracorporeal instrument collision, and reduced maneuverability. Studies comparing the maneuverability of the scopes and instruments in different SPASs are lacking. This study aimed to compare the maneuverability of three different SPASs: the Covidien SILS-port, Storz Endocone, and glove port. A clear acrylic box with artificial skin placed at the bottom was used to mimic the abdominal wall and cavity. The three SPASs were placed from below, and a 10-mm endoscope and 5-mm instrument were introduced. A motion analysis system consisting of 18 cameras and motion analysis software were used to track the movement of the endoscope and instrument, to determine the volume of the cone-shaped, three-dimensional figures over which movement was possible, with higher values indicating greater maneuverability. The Mann–Whitney U test was used for the analysis. The maneuverability of the endoscope alone was significantly higher in the glove port system than in the other two SPASs. When inserting an additional instrument, the maneuverability significantly decreased in the SILS-port and Endocone, but not in the glove port. The highest maneuverability overall was found in the glove port.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
D Trifunovic Zamaklar ◽  
G Krljanac ◽  
M Asanin ◽  
L Savic-Spasic ◽  
J Vratonjic ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. onbehalf PREDICT-VT More extensive coronary atherosclerosis in diabetes mellitu (DM) induces poorer clinical outcomes after STEMI, but there are data suggesting that impaired myocardial function in DM, even independently from epicardial coronary lesions severity, might have detrimental effect, predominately on heart failure development in DM. Aim the current study is a sub-study of PREDICT-VT study (NCT03263949), aimed to analyse LV and LA function using myocardial deformation imaging based on speckle tracking echocardiography after pPCI in STEMI patients with and without DM. Methods in 307 consecutive pts enrolled in PREDICT-VT study early echocardiography (5 ± 2 days after pPCI) was done including LA and multilayer LV deformation analysis with longitudinal (L), radial (R) and circumferential (C) strain (S; %) and strain rate (SR, 1/sec), LV index of post systolic shortening for longitudinal (PSS LS) and circumferential (PSS CS) strains and analysis of LV rotation mechanic. Results from 242 patients who completed 1 year follow up, 48 (20%) had DM. Pts with DM were older (60 ± 1,01 vs 57 ± 10; p = 0.067) and had insignificantly higher SYNTAX score (18.5 ± 9.2 vs 15.8 ± 9.8, p = 0.118) . However, diabetics had more severely impaired EF (44.2 ± 8.6 vs 49.2 ± 9.8, p = 0.001), E/A ratio (0.78 ± 0.33 vs 0.90 ± 0.34; p = 0.036) and MAPSE (1.18 ± 0.32 vs 1.32 ± 0.33; p = 0.001).  Global LV LS on all layers (endo: -13.6 ± 4.0 vs-16.2 ± 4.7; mid: -11.9 ± 3.5 vs -14.1 ± 4.1; epi: -10.4 ± 3.1 vs -12.3 ± 3.6; p < 0.005 for all) was impaired in DM patients, as well as longitudinal systolic SR (-0.71 ± 0.23 vs -0.84 ± 0.24; p = 0.001) and SR during early diastole (0.65 ± 0.26 vs 0.83 ± 0.33, p < 0.001). Patients with DM had more pronounced longitudinal posts-systolic shortening throughout LV wall (endo: 21.4 ± 16.1 vs 13.7 ± 13.3, p = 0.005; mid: 21.9 ± 16.1 vs 14.3 ± 13.1, p = 0.006; epi: 22.4 ± 16.5 vs 15.3 ± 13.7, p = 0.010) and higher LV mechanical dispersion (MDI: 71.3 ± 38.3 vs 59.0 ± 18.9, p = 0.037). LA strain was significantly impaired in DM patients (18.9 ± 7.7 vs 22.6 ± 10.0, p = 0.011) and even more profoundly LA strain rate during early diastole (-0.73 ± 0.48 vs -1.00 ±0.58, p = 0.002). Patients with DM also had more impaired LV global (15.7 ± 9.1 vs 19.8 ± 10.4, p = 0.013) radial strain, global LV circumferencial strain, especially at the mid-wall level (-13.9 ± 4.2 vs -16.0 ± 4.3, p = 0.005) and impaired circumferential SR E (1.25± 0.44 vs 1.49 ± 0.46, p = 0.003). End-systolic rotation of the LV apex was more impaired in DM (4.7 ± 5.1 vs 6.8 ± 5.5, p= 0.022). During 1 year follow-up heart failure and all-cause mortality tend to be higher among DM pts (46.7% vs 35.2%, p = 0.153). Conclusion STEMI patients with DM have more severely impaired LV systolic and diastolic function estimated both by traditional parameter and advanced echo techniques. These results might, at least partially, explain why outcomes after STEMI in DM might be poorer, even in the absence of more complex angiographic findings, pointing to the significance of impaired myocardial function DM itself.


Sign in / Sign up

Export Citation Format

Share Document