Variation of radiotherapy target volume definition, dose to organs at risk (OAR) and clinical target volumes using anatomic (CT) versus combined anatomic and molecular imaging (PET-CT): Intensity Modulated Radiotherapy delivered using a Tomotherapy Hi Art machine

2013 ◽  
Author(s):  
Sanjoy Chatterjee
Rare Tumors ◽  
2016 ◽  
Vol 9 (1) ◽  
pp. 7-8 ◽  
Author(s):  
Francesco Cuccia ◽  
Vanessa Figlia ◽  
Antonella Palmeri ◽  
Francesco Verderame ◽  
Antonio Lo Casto ◽  
...  

Angiosarcoma of the scalp is a rare aggressive tumor that affects elderly patients. Chemoradiation is the treatment of choice for multicentric and extensive disease. The shape of the scalp represents a dosimetric challenge in terms of achieving a homogeneous concave dose distribution with coverage of the entire target volume and an acceptable organs-at-risk sparing. We report a case of an 81-year-old man with a multifocal angiosarcoma of the scalp treated with Helical TomoTherapy® (Accuray Inc., Sunnyvale, CA, USA) intensity modulated radiotherapy. This technique allows precise and daily verifiable coverage of the target keeping the dose to the organs at risk within the constraints.


2006 ◽  
Vol 13 (3) ◽  
pp. 108-115 ◽  
Author(s):  
O. Ballivy ◽  
W. Parker ◽  
T. Vuong ◽  
G. Shenouda ◽  
H. Patrocinio

We assessed the effect of geometric uncertainties on target coverage and on dose to the organs at risk (OARS) during intensity-modulated radiotherapy (IMRT) for head-and-neck cancer, and we estimated the required margins for the planning target volume (PTV) and the planning organ-at-risk volume (PRV). For eight headand- neck cancer patients, we generated IMRT plans with localization uncertainty margins of 0 mm, 2.5 mm, and 5.0 mm. The beam intensities were then applied on repeat computed tomography (CT) scans obtained weekly during treatment, and dose distributions were recalculated. The dose–volume histogram analysis for the repeat CT scans showed that target coverage was adequate (V100 ≥ 95%) for only 12.5% of the gross tumour volumes, 54.3% of the upper-neck clinical target volumes (CTVS), and 27.4% of the lower-neck CTVS when no margins were added for PTV. The use of 2.5-mm and 5.0-mm margins significantly improved target coverage, but the mean dose to the contralateral parotid increased from 25.9 Gy to 29.2 Gy. Maximum dose to the spinal cord was above limit in 57.7%, 34.6%, and 15.4% of cases when 0-mm, 2.5-mm, and 5.0-mm margins (respectively) were used for PRV. Significant deviations from the prescribed dose can occur during IMRT treatment delivery for headand- neck cancer. The use of 2.5-mm to 5.0-mm margins for PTV and PRV greatly reduces the risk of underdosing targets and of overdosing the spinal cord.


2014 ◽  
Vol 111 (2) ◽  
pp. 281-288 ◽  
Author(s):  
Esengul Kocak-Uzel ◽  
G. Brandon Gunn ◽  
Rivka R. Colen ◽  
Micheal E. Kantor ◽  
Abdallah S.R. Mohamed ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document