scholarly journals Clinical and radiological results of high offset tri-lock bone preservation stem in unilateral primary total hip arthroplasty at a minimum follow-up of 3 years

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Linbo Peng ◽  
Jun Ma ◽  
Yi Zeng ◽  
Yuangang Wu ◽  
Haibo Si ◽  
...  

Abstract Background Although the high offset Tri-Lock bone preservation stem (BPS) was used widely, few studies explored the clinical and radiological results. The purpose of this study was to determine the clinical and radiological results of high offset Tri-Lock BPS in unilateral primary total hip arthroplasty (THA) at a minimum follow-up of 3 years. Methods 55 patients who underwent cementless THA with high offset Tri-lock BPS from 2017 to 2018 were followed for a minimum follow-up of 3 years. Patients were assessed clinically for complications, Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Oxford Hip Score (OHS). Femoral offset (FO), acetabular offset (AO), hip offset (HO), HO difference, and leg length discrepancy (LLD) were measured on the anteroposterior (AP) pelvic radiograph. Standard pelvic AP and lateral radiographs were used to evaluate for evidence of bone ingrowth, stem subsidence, stem alignment, radiolucent line around the stem, osteolysis, loosening, ectopic ossification, and femoral stress shielding. Results No patients reported complications during hospitalization nor the follow-up period. At a mean follow-up of 42.5 months, the mean HHS, WOMAC, and OHS scores showed a significant improvement from preoperative to the latest follow-up. No patients reported thigh pain. No revision nor sign of radiographic loosening had been detected. The high offset Tri-Lock BPS significantly improved the FO and HO postoperatively. HO difference and LLD were balanced postoperatively. No sign of stem subsidence, radiolucent line, osteolysis, loosening, ectopic ossification, nor severe stress shielding (more than grade 3–4) were observed at the latest follow-up. Conclusion The high offset Tri-Lock BPS demonstrated excellent clinical and radiographic outcomes at a minimum follow-up of 3 years. HO difference and LLD between legs decreased significantly and achieved balance postoperatively. Long-term follow-up is required for a definitive conclusion.

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
I. Tatani ◽  
K. Solou ◽  
A. Panagopoulos ◽  
J. Lakoumentas ◽  
A. Kouzelis ◽  
...  

Abstract Background There is great design variability on short femoral stems available on the market. This study aims to evaluate the short-term clinical and radiological results of two different design short femoral stems, both classified as shortened tapered stems. Methods From March 2016 to March 2018, a prospective, randomized, parallel-group design study was conducted to compare functional and radiological outcomes of 45 patients underwent THA using the Tri-Lock Bone Preservation Stem and 45 patients underwent THA with the Minima S stem at a minimum 2 years of follow-up. Patients were assessed clinically and radiographically prior to surgery as well as at 3, 6, 12, and 24 months postoperatively. Primary outcomes were the change in health-related quality of life assessed with Western Ontario and McMaster Universities Osteoarthritis Index and 36-Item Short Form Health Survey and also the incidence of all hip-related complications. Secondary aims included hip function evaluated with the Harris hip score, rates of patient satisfaction, and the outcomes of a detailed radiological analysis. Results There were no significant differences between the 2 study groups in terms of patient-reported outcomes measurements, satisfaction scores, and complication rates at any of the measurement times. In both groups, stable fixation and radiographic osseointegration were achieved. However, analysis of the calcar region showed that 57.8% and 28.9% of patients had grade 1 or 2 stress shielding, in Tri-Lock and Minima S implantation group, respectively (p=0.015). Regarding coronal alignment, stems were placed in slight varus, valgus, and neutral position in 51.1%, 13.3%, and 35.6% of patients, respectively, in Tri-Lock BPS group. The Minima S stem was implanted at slight varus and valgus in 60% and 40% of patients, respectively, and neither stem in the exact neutral position. Conclusions Both different design short femoral stems demonstrated excellent clinical performance at short-term follow up. Nevertheless, concerns were raised regarding the incidence of stress shielding phenomenon and mild discrepancies in coronal stem alignment during implantation. The clinical impact of these observations should be further evaluated through larger cohorts and longer follow-up. Trial registration ISRCTN registry, ISRCTN10096716. Registered on May 8, 2018—Retrospectively registered


2020 ◽  
pp. 112070002096964
Author(s):  
Kirill Gromov ◽  
Nanna H Sillesen ◽  
Thomas Kallemose ◽  
Henrik Husted ◽  
Henrik Malchau ◽  
...  

Background: Introduction of new implants should be monitored closely to capture any signs of compromising patient safety. Vitamin E infused highly-crosslinked polyethylene liners (VEPE) offer the potential for reduced wear. Highwall liners have been hypothesised to result in increased wear and potential liner fractures. The aim of this study was to determine the 3–7-year follow-up of highwall VEPE for primary total hip arthroplasty (THA), focusing on liner-related complications. Methods: We included 1221 consecutive THA operations from July 2010 to May 2014 with minimum follow-up of 3 (3.1–6.8) years Data collected included demographics, implant data, complications, reoperations, and deaths. Data were cross-referenced with the Danish Hip Arthroplasty Registry in order to ensure validity and completeness. Acetabular shell position was measured using Martell Hip Analysis Suite in a subgroup of 931 THAs. Results: Cumulative stem revision and shell revision at 3-year follow-up was 3.4% and 0.4% respectively. There were no revisions due to liner failure. Reason for revision included 11 dislocations, 15 soft-tissue revisions for infection, 44 stem revisions of which 34 were periprosthetic fractures and 13 shell revisions of which 6 were combined shell and stem revisions. Conclusion: Early follow-up of VEPE liners for primary THA have not shown any revisions associated with liner failure. Continued monitoring of new materials are necessary to capture any signs of compromised patient safety.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Nicola Piolanti ◽  
Lorenzo Andreani ◽  
Paolo Domenico Parchi ◽  
Enrico Bonicoli ◽  
Francesco Niccolai ◽  
...  

Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60) of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1%) showed thigh pain and only 4 hips (12.11%) presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results.


2017 ◽  
Vol 01 (04) ◽  
pp. 200-204 ◽  
Author(s):  
Roby Abraham ◽  
Joseph Scollan ◽  
Patrick Mixa ◽  
Denis Cherkalin ◽  
Jeffrey Varghese ◽  
...  

AbstractGunshot wound (GSW) injuries around the hip joint can lead to debilitating post-traumatic arthritis, requiring a technically demanding primary total hip arthroplasty (THA). These surgeries are often complicated by bullet debris, extensive scaring, prior operations, and altered local anatomy. Although most literature focuses on acute management of GSW around the hip, a few reports detail the mid-term outcomes of GSW patients with primary THA for post-traumatic arthritis. The purpose of this study was to assess the outcomes and complications associated with THA in nine patients with secondary arthritis due to prior GSW injuries. At a mean follow-up of 35 months (range 12–60 months), significant improvement was shown in hip function, activity, and pain levels, and was similar to the outcomes of 18 patients who underwent primary THA for degenerative joint disease. While technically demanding, THA seems to reduce pain and improve function safely and effectively for patients with GSW-induced hip arthritis.


2021 ◽  
Vol 2 (12) ◽  
pp. 1035-1042
Author(s):  
Maciej Okowinski ◽  
Mette Holm Hjorth ◽  
Sebastian Breddam Mosegaard ◽  
Jonathan Hugo Jürgens-Lahnstein ◽  
Stig Storgaard Jakobsen ◽  
...  

Aims Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. Methods A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications. Results Over a mean follow-up period of 10.6 years, the mean stem subsidence was similar between groups, with a mean of -1.20 mm (95% confidence interval (CI) -2.28 to -0.12) in the broaching group and a mean of -0.73 mm (95% CI -1.65 to 0.20) in the compaction group (p = 0.07). The long-term migration patterns of all stems were similar. The clinical and radiological outcomes were similar between groups. There were two intraoperative fractures in the compaction group that were fixed with cable wire and healed without complications. No stems were revised. Conclusion Similar stem subsidence and radiological and clinical outcomes were identified after the use of compaction and broaching techniques of the femur at long-term follow-up. Only the compaction group had intraoperative periprosthetic femur fractures, but there were no long-term consequences of these. Cite this article: Bone Jt Open 2021;2(12):1035–1042.