scholarly journals Assessment of CareStart G6PD rapid diagnostic test and CareStart G6PD biosensor in Mauritania

2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Oum Kelthoum Mamadou Djigo ◽  
Yacoub Ould Khalef ◽  
Mohamed Salem Ould Ahmedou Salem ◽  
Nicolas Gomez ◽  
Leonardo Basco ◽  
...  

Abstract Background The elimination of Plasmodium vivax malaria requires 8-aminoquinolines, which are contraindicated in patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency due to the risk of acute haemolytic anaemia. Several point-of-care devices have been developed to detect G6PD deficiency. The objective of the present study was to evaluate the performance of two of these devices against G6PD genotypes in Mauritania. Methods Outpatients were screened for G6PD deficiency using CareStart™ rapid diagnostic test (RDT) and CareStart™ G6PD biosensor in Nouakchott, Mauritania, in 2019–2020. African-type and Mediterranean-type G6PD genotypes commonly observed in Africa were determined by polymerase chain reaction-restriction fragment length polymorphism and sequencing. Qualitative variables were compared using Fisher’s exact test. Results Of 323 patients (74 males and 249 females), 5 males and 2 homozygous females had the African-type A- genotype: A−(202) in 3 males and 2 females and G6PD A−(968) in 2 males. Among heterozygous females, 13 carried G6PD A−(202), 12 G6PD A−(968), and 3 G6PD A−(542) variants. None had the Mediterranean-type G6PD genotype. Eight had a positive G6PD RDT result, including all 7 hemizygous males and homozygous females with A- or A-A- (0.12 to 2.34 IU/g haemoglobin, according to G6PD biosensor), but RDT performed poorly (sensitivity, 11.1% at the cut-off level of < 30%) and yielded many false negative tests. Thirty-seven (50.0%) males and 141 (56.6%) females were anaemic. The adjusted median values of G6PD activity were 5.72 and 5.34 IU/g haemoglobin in non-anaemic males (n = 35) and non-anaemic males and females (n = 130) with normal G6PD genotypes using G6PD biosensor, respectively. Based on the adjusted median of 5.34 IU/g haemoglobin, the performance of G6PD biosensor against genotyping was as follows: at 30% cut-off, the sensitivity and specificity were 85.7% and 91.7%, respectively, and at 80% cut-off, the sensitivity was 100% while the specificity was 64.9%. Conclusions Although this pilot study supports the utility of biosensor to screen for G6PD deficiency in patients, further investigation in parallel with spectrophotometry is required to promote and validate a more extensive use of this point-of-care device in areas where P. vivax is highly prevalent in Mauritania. Graphic abstract

2011 ◽  
Vol 58 (2) ◽  
pp. 163-164 ◽  
Author(s):  
I. T. Runsewe-Abiodun ◽  
M. Efunsile ◽  
B. Ghebremedhin ◽  
A. S. Sotimehin ◽  
J. Ajewole ◽  
...  

2016 ◽  
Vol 22 (1) ◽  
pp. 21-31
Author(s):  
Henry Maia Peixoto ◽  
Marcelo Augusto Mota Brito ◽  
Gustavo Adolfo Sierra Romero ◽  
Wuelton Marcelo Monteiro ◽  
Marcus Vinícius Guimarães de Lacerda ◽  
...  

PLoS ONE ◽  
2015 ◽  
Vol 10 (4) ◽  
pp. e0125796 ◽  
Author(s):  
Dennis Adu-Gyasi ◽  
Kwaku Poku Asante ◽  
Sam Newton ◽  
David Dosoo ◽  
Sabastina Amoako ◽  
...  

2015 ◽  
Vol 20 (23) ◽  
Author(s):  
S L Becker ◽  
H Marti ◽  
S Zimmermann ◽  
D Vidacek ◽  
M Herrmann ◽  
...  

In February 2015, a male patient from Eritrea with persistent abdominal pain and rectal bleeding was diagnosed with Schistosoma mansoni infection upon examination of a rectal biopsy. In May 2015, repeated stool microscopy identified S. mansoni infection in another Eritrean patient with abdominal pain and considerable eosinophilia (34%). Use of point-of-care circulating cathodic antigen (POC-CCA) tests on urine confirmed S. mansoni infection in both patients. Wider application of non-invasive POC-CCA urine tests will improve schistosomiasis diagnosis and clinical management in migrants.


Sign in / Sign up

Export Citation Format

Share Document