scholarly journals Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Jaafar Abduo ◽  
Joseph E. A. Palamara

Abstract Background Accurate implant impression is an essential requirement for the fabrication of implant prosthesis. This in vitro study evaluated the accuracy of digital impressions by intraoral scanner (IOS) systems in comparison to conventional impressions for recording the position of 2 parallel implants and 2 divergent implants. Materials and methods In vitro 3-unit prosthesis master models with 2 tissue level implants were fabricated; one model had parallel implants, and the other model had one 15° tilted implant. The conventional open-tray impressions were obtained with non-splinted (NSP) and splinted (SP) impression copings. Trios 4 (TS), Medit i500 (MT), and True Definition (TD) were used to make digital impressions with scan bodies. A total of 10 impressions were obtained with every technique. The virtual test images of the conventional and digital impressions were converted to 2 virtual implant images. For each group, trueness, precision, inter-implant distance deviation, and angle deviation were measured. Results There was a general tendency for digital impressions to provide a more accurate outcome for trueness, precision, and angle deviation. The 2 conventional impressions showed similar accuracy, except for the angle deviation, where the NSP was significantly inferior than SP (p < 0.01) for the divergent implants model. The TD was generally the least accurate among all the IOS systems, especially for the inter-implant distance deviation (p < 0.05). Conclusions Within the limitations of the laboratory set-up of the present study and the limited clinical resemblance, the digital impressions appeared to have sufficient accuracy for 2 implants and were least affected by the presence of angle between implants. The most inferior outcome was observed for the NSP technique.

Materials ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 3543
Author(s):  
Marco Tallarico ◽  
Aurea Lumbau ◽  
Roberto Scrascia ◽  
Gianluca Demelas ◽  
Franco Sanseverino ◽  
...  

Background: Intraoral scanners (IOSs) in implantology represent a viable approach for single teeth or partial arches. However, when used for complete edentulous arches or long-span edentulous areas, it has been demonstrated that there is a need for improvement of IOS-related techniques. Therefore, the aim of this in vitro study was to assess the trueness and precision of a complete arch digital impression on four and six implants taken with or without a customized, prosthetic-based impression template. Materials and Methods: Two experimental models were prepared, representative of a complete edentulous mandible restored with four and six implants with built-in scan abutments. Models were scanned with (test group, TG) or without (control group, CG) the prosthetic-based impression template. Eight scans were taken for each model. The time needed to take impressions, error, trueness, and precision were evaluated. A statistical analysis was performed. Results: In the case of four implants, the time needed for the impression was 128.7 ± 55.3 s in the TG and 81.0 ± 23.5 s in the CG (p = 0.0416). With six scan abutments, the time was 197.5 ± 26.8 and 110.6 ± 25.2 s in the TG and CG, respectively (p = 0.0000). In the TG, no errors were experienced, while in the CG, 13 impressions were retaken due to incorrect stitching processes. In the four-implant impression, the mean angle deviation was 0.252 ± 0.068° (95% CI 0.021–0.115°) in the CG and 0.134 ± 0.053° (95% CI 0.016–0.090°) in the TG. The difference was statistically significant (p = 0.002). In the six-implant impression, the mean angle deviation was 0.373 ± 0.117° (95% CI 0.036–0.198°) in the CG and 0.100 ± 0.029° (95% CI 0.009–0.049°) in the TG (p = 0.000). In the TG, there were no statistically significant differences in the mean angle deviation within the group (p > 0.05), but there were in the CG. A colorimetric analysis showed higher deviations from the original model for the six-implant impression without a prosthetic template. Conclusions: Although all of the impressions exhibited deviation from the original model in the range of clinical acceptability, the prosthetic-based impression template significantly improved the trueness and precision of complete edentulous arches rehabilitated with four or six implants, making the complete arch digital impression more predictable.


Materials ◽  
2020 ◽  
Vol 13 (19) ◽  
pp. 4349
Author(s):  
Ahmad Ibrahim ◽  
Marius Heitzer ◽  
Anna Bock ◽  
Florian Peters ◽  
Stephan Christian Möhlhenrich ◽  
...  

Aim: This in vitro study aimed to evaluate the effects of implant designs on primary stability in different bone densities and bony defects. Methods: Five implant types (tapered-tissue-level, tissue-level, zirconia-tissue-level, bone-level, and BLX implants) were used in this assessment. The implants were inserted into four different artificial bone blocks representing varying bone-density groups: D1, D2, D3, and D4. Aside from the control group, three different types of defects were prepared. Using resonance frequency analysis and torque-in and -out values, the primary stability of each implant was evaluated. Results: With an increased defect size, all implant types presented reduced implant stability values measured by the implant stability quotient (ISQ) values. Loss of stability was the most pronounced around circular defects. Zirconia and bone-level implants showed the highest ISQ values, whereas tissue level titanium implants presented the lowest stability parameters. The implant insertion without any thread cut led to a small improvement in primary implant stability in all bone densities. Conclusions: Compared with implants with no peri-implant defects, the three-wall and one-wall defect usually did not provide significant loss of primary stability. A significant loss of stability should be expected when inserting implants into circular defects. Implants with a more aggressive thread distance could increase primary stability.


2002 ◽  
Vol 15 (1-2) ◽  
pp. 77-84 ◽  
Author(s):  
Steen Karstrup ◽  
Jens Brøns ◽  
Lone Morsel ◽  
Niels Juul ◽  
Peter von der Recke

2019 ◽  
Vol 44 (2) ◽  
pp. 73-76
Author(s):  
Diana M. Abdelazeem ◽  
Samir A. Koheil ◽  
Wegdan M. Abdel-Fattah

2021 ◽  
Vol 36 (3) ◽  
pp. 442-449
Author(s):  
Yi-Jie Zhang ◽  
Shi-Chong Qiao ◽  
Shu-Jiao Qian ◽  
Chu-Nan Zhang ◽  
Jun-Yu Shi ◽  
...  