scholarly journals The effect of soft tissue augmentation on the clinical and radiographical outcomes following immediate implant placement and provisionalization: a systematic review and meta-analysis

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Paolo De Angelis ◽  
Paolo Francesco Manicone ◽  
Edoardo Rella ◽  
Margherita Giorgia Liguori ◽  
Silvio De Angelis ◽  
...  

Abstract Background Nowadays, due to the esthetic and social demands of patients, conventional staged protocols seem to be increasingly replaced by faster, one-step protocols. The purpose of the present systematic review is to assess the peri-implant soft tissue changes after immediate implant placement and provisionalization (IIPP) comparing patients treated with or without a sub-epithelial connective tissue graft (SCTG) when replacing a single tooth in the esthetic region. Methods The present systematic review was written following the PRISMA checklist. Immediate implants placed with a connective tissue graft and without one were compared. The researched primary outcomes were the mid-buccal mucosa level (MBML) facial soft tissue thickness (FSTT) and marginal bone loss (MBL). The weighted mean differences (WMD) were estimated for all three outcomes. Results The change in the mid-buccal mucosa level in the intervention group was significantly higher (WMD 0.54; 95% CI 0.33–0.75), with no indication of heterogeneity (I2 = 16%). The facial soft tissue thickness increased significantly in the intervention group (WMD 0.79; 95% CI 0.37–1.22). The marginal bone loss was significantly higher in the control group (WMD 0.13; 95% CI 0.07–0.18), with no indication of heterogeneity (I2 = 0%). Conclusions The results of the meta-analyses showed a statistically significant reduced change of the marginal bone loss and vestibular recession, as well as higher soft tissue thickness, when a graft was used. The included studies had a short observation time; therefore, studies with longer follow-ups are needed to confirm these findings.

2016 ◽  
Vol 87 (6) ◽  
pp. 690-699 ◽  
Author(s):  
Fernando Suárez-López del Amo ◽  
Guo-Hao Lin ◽  
Alberto Monje ◽  
Pablo Galindo-Moreno ◽  
Hom-Lay Wang

2016 ◽  
Vol 28 (9) ◽  
pp. 1046-1053 ◽  
Author(s):  
Aliye Akcalı ◽  
Anna Trullenque-Eriksson ◽  
Chuanming Sun ◽  
Aviva Petrie ◽  
Luigi Nibali ◽  
...  

Materials ◽  
2018 ◽  
Vol 11 (1) ◽  
pp. 119 ◽  
Author(s):  
Jose Calvo Guirado ◽  
Aldo Lucero-Sánchez ◽  
Ana Boquete Castro ◽  
Marcus Abboud ◽  
Sergio Gehrke ◽  
...  

The aim of this study was to evaluate the soft tissue thickness and marginal bone loss around dental implants with sloped micro-threaded shoulder (30° angle) in comparing with conventional design, inserted 30° degrees angulated in post extraction sockets and immediate loaded with temporary prosthesis simulating the all-on-four protocol. Materials and Methods: Six fox hound dogs received forty-eight post extraction dental implants with the different diameter and length (Medentika, Germany), but with different neck configurations. Two group of implants were inserted 1mm subcrestal. Control group has a micro-threaded neck and the Test group has a sloped microthreaded neck. Immediate loading was applied using a constructed metallic structure. After three months, soft and hard tissue levels were assessed by histomorphometric analysis. Results: The mean soft tissue thickness (STT) was 2.5 ± 0.2 mm for the Control group and 3.3 ± 0.3 mm for Test group (p = 0.036), meanwhile the mean marginal bone loss (MBL) was 1.53 ± 0.34 mm for Control group and, 1.62 ± 0.22 mm for Test group (p > 0.05). Conclusions: Within the limitations of this experimental model in dogs, the findings showed that dental implants with microthreaded and microthreaded sloped necks installed in immediate post extraction sites with immediate load, presented a comparable perimplant tissue behavior.


2021 ◽  
Vol 9 (D) ◽  
pp. 257-263
Author(s):  
Darko Veljanovski ◽  
Aneta Atanasovska-Stojanovska ◽  
Aleksandra Pivkova-Veljanovska ◽  
Eitan Mijiritsky ◽  
Curd Bollen

Aim The aim of this prospective study was to determine the influence of vertical soft tissue thickness on bone level changes in platform-switched implants placed eqicrestally or subcrestally and restored with screw-retained or cement-retained restorations. Methods Platform-switched bone-level implants were placed in a single stage manner in the posterior mandibular region. Implant sites were divided into thick (control) and thin (test) vertical soft tissue groups. The implants in the control group were placed equicrestally. The implant sites from the control group were randomly allocated to receive equicrestally or subcrestally placed implants. Bone remodeling/loss was radiographically measured at baseline, three months postoperatively and six months after delivery of final prosthetic restoration. Results The mean crestal bone loss values three months postoperatively and six months post prosthetic restoration were higher in sites with thin versus sites with thick gingiva. In implant sites with thin gingiva, subcrestally placed implants presented less bone loss than eqicrestally placed implants. Conclusion Platform switched implants are prone to more bone loss when they are placed in sites with thin soft tissue, regardless of the type of final restoration (screw-retained or cement-retained). Subcrestal placement of platform-switched implants can prevent crestal bone loss in sites with vertical soft tissue thickness < 3 mm.    


2021 ◽  
pp. 200460
Author(s):  
Diana Toneva ◽  
Silviya Nikolova ◽  
Stanislav Harizanov ◽  
Dora Zlatareva ◽  
Vassil Hadjidekov

2019 ◽  
Vol 294 ◽  
pp. 217.e1-217.e7 ◽  
Author(s):  
Fouad Ayoub ◽  
Maria Saadeh ◽  
Georges Rouhana ◽  
Ramzi Haddad

2020 ◽  
pp. 002580242097701
Author(s):  
Tobias MR Houlton ◽  
Nicolene Jooste ◽  
Maryna Steyn

Average facial soft-tissue thickness (FSTT) databanks are continuously developed and applied within craniofacial identification. This study considered and tested a subject-specific regression model alternative for estimating the FSTT values for oral midline landmarks using skeletal projection measurements. Measurements were taken from cone-beam computed tomography scans of 100 South African individuals (60 male, 40 female; Mage = 35 years). Regression equations incorporating sex categories were generated. This significantly improved the goodness-of-fit ( r2-value). Validation tests compared the constructed regression models with mean FSTT data collected from this study, existing South African FSTT data, a universal total weighted mean approach with pooled demographic data and collection techniques and a regression model approach that uses bizygomatic width and maximum cranial breadth dimensions. The generated regression equations demonstrated individualised results, presenting a total mean inaccuracy (TMI) of 1.53 mm using dental projection measurements and 1.55 mm using cemento-enamel junction projection measurements. These slightly outperformed most tested mean models (TMI ranged from 1.42 to 4.43 mm), and substantially outperformed the pre-existing regression model approach (TMI = 5.12 mm). The newly devised regressions offer a subject-specific solution to FSTT estimation within a South African population. A continued development in sample size and validation testing may help substantiate its application within craniofacial identification.


2020 ◽  
Vol 31 (S20) ◽  
pp. 180-180
Author(s):  
Alper Saglanmak ◽  
Alper Gultekin ◽  
Caglar Cinar ◽  
Cuneyt Karabuda ◽  
Serge Szmukler‐Moncle

2018 ◽  
Vol 8 (2) ◽  
pp. 22-28
Author(s):  
Ravi Kumar Mahto ◽  
Dashrath Kafle ◽  
Pankaj Kumar Singh ◽  
Sonika Khanal ◽  
Siddhartha Khanal

Introduction: Variations in facial soft tissue thickness have been established previously by studies conducted in different population. Hence, it is essential to obtain facial soft tissue thickness measurement data specific to a population and develop individual standards. The objective of this research is to obtain facial soft tissue thickness data of Nepalese adult male and female subjects seeking orthodontic treatment with different sagittal skeletal malocclusion and evaluate variations in facial soft tissue thickness. Materials & Method: Facial soft tissue thicknesses was measured manually on ninety pretreatment lateral cephalogram at eleven points (Glabella, Nasion, Rhinion, Subnasale, Labrale superius, Stomion, Labrale inferius, Labiomentale, Pogonion,Gnathion and Menton). One-way Analysis of variances [one-way ANOVA] followed by Least significant difference (LSD) post hoc test was used to determine difference in facial soft tissue thickness measurements among three sagittal skeletal group for both sexes. In addition, Student’s t-test was used to find difference in facial soft tissue thickness between the male and female subjects in each skeletal Class. Result: Statistically significant differences were found at points Rhinion, Subnasale, Labrale superius, Stomion and Gnathion in males and at Subnasale, Labrale superius, Stomion and Labrale inferius in females while comparing facial soft tissue thickness among three sagittal skeletal classes. Also, it was observed that mean facial soft tissue thickness was greater for males as compared to female subjects with significant differences at Subnasale, Labrale superius, and Labrale inferius in each skeletal Class. Conclusion: Facial soft tissue thickness varies considerably among different population group, sex and sagittal relationship of jaws.


Sign in / Sign up

Export Citation Format

Share Document