Inferior vena cava collapsibility index as a predictor of fluid responsiveness in sepsis-related acute circulatory failure

2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Ahmed Ibrahim Nagi ◽  
Azza Mohamed Shafik ◽  
Amr Mohamed Abdel Fatah ◽  
Wessam Zaher Selima ◽  
Amira Fathy Hefny

Abstract Background Assessing fluid responsiveness is the key to successful resuscitation of critically-ill sepsis patients. The use of IVC variation is favored among the dynamic methods of fluid responsiveness assessment in the ICU because it is non-invasive and inexpensive; moreover, it does not demand a high level of training. The aim of this study is to determine the value of the IVC respiratory variability for predicting fluid responsiveness in spontaneously breathing sepsis patients with acute circulatory failure. Results In this prospective observational study, fifty-eight spontaneously breathing sepsis patients admitted in the ICU were enrolled after the approval of the departmental Research Ethical Committee, and the informed written consent had been taken from the patients. Ultrasonographic and echocardiographic parameters were measured “IVC parameters and stroke volume (SV)” with calculation of the inferior vena cava collapsibility index (IVCCI) and cardiac output. These values were obtained before (baseline) and after volume expansion with a fluid bolus. The study showed that twenty-nine patients (50%) were considered to be responders, with an increase in CO by 10% or more after fluid challenge. There was a significant difference between responders and non-responders in baseline IVCCI (p value < 0.001). There were no significant differences between responders and non-responders in terms of demographic and baseline clinical characteristics. Also, there was statistically significantly larger maximum (IVC max) and minimum (IVC min) inferior vena cava diameters before volume expansion in non-responders than in responders with p value 0.037 and 0.001 respectively. The suggested cut off value regarding baseline IVCCI to predict response to fluid infusion is 0.32 with a high chance of response above this figure (a sensitivity of 72.41% and a specificity of 82.76%). Conclusions Inferior vena cava collapsibility index assessment can be a sensitive and a good predictor of fluid responsiveness, being based on a safe and a non-invasive technique compared to other methods such as central venous pressure (CVP) measurement and pulmonary artery catheter insertion.

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Morgan Caplan ◽  
Arthur Durand ◽  
Perrine Bortolotti ◽  
Delphine Colling ◽  
Julien Goutay ◽  
...  

Abstract Background The collapsibility index of the inferior vena cava (cIVC) has potential for predicting fluid responsiveness in spontaneously breathing patients, but a standardized approach for measuring the inferior vena cava diameter has yet to be established. The aim was to test the accuracy of different measurement sites of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with sepsis-related circulatory failure and examine the influence of a standardized breathing manoeuvre. Results Among the 81 patients included in the study, the median Simplified Acute Physiologic Score II was 34 (24; 42). Sepsis was of pulmonary origin in 49 patients (60%). Median volume expansion during the 24 h prior to study inclusion was 1000 mL (0; 2000). Patients were not severely ill: none were intubated, only 20% were on vasopressors, and all were apparently able to perform a standardized breathing exercise. Forty-one (51%) patients were responders to volume expansion (i.e. a ≥ 10% stroke volume index increase). The cIVC was calculated during non-standardized (cIVC-ns) and standardized breathing (cIVC-st) conditions. The accuracy with which both cIVC-ns and cIVC-st predicted fluid responsiveness differed significantly by measurement site (interaction p < 0.001 and < 0.0001, respectively). Measuring inferior vena cava diameters 4 cm caudal to the right atrium predicted fluid responsiveness with the best accuracy. At this site, a standardized breathing manoeuvre also significantly improved predictive power: areas under ROC curves [mean and (95% CI)] for cIVC-ns = 0.85 [0.78–0.94] versus cIVC-st = 0.98 [0.97–1.0], p < 0.001. When cIVC-ns is superior or equal to 33%, fluid responsiveness is predicted with a sensitivity of 66% and a specificity of 92%. When cIVC-st is superior or equal to 44%, fluid responsiveness is predicted with a sensitivity of 93% and a specificity of 98%. Conclusion The accuracy with which cIVC measurements predict fluid responsiveness in spontaneously breathing patients depends on both the measurement site of inferior vena cava diameters and the breathing regime. Measuring inferior vena cava diameters during a standardized inhalation manoeuvre at 4 cm caudal to the right atrium seems to be the method by which to obtain cIVC measurements best-able to predict patients’ response to volume expansion.


2021 ◽  
Author(s):  
Hanan El-Halaby ◽  
Ashraf Bakr ◽  
Mohamed El-Assmy ◽  
Hussein Abdelaziz Abdalla ◽  
Marwa Salem ◽  
...  

Abstract Evaluating the volume status in children with Idiopathic nephrotic syndrome (INS) is mandatory to guide treatment and avoid unnecessary possibly hazardous albumin use. This study aimed to evaluate and compare the available tools used for volume status assessment and differentiating type of edema in children with INS. Sixty children with active INS were included and subdivided into hypovolemic and non-hypovolemic groups based on fractional excretion of sodium (FeNa%) and clinical assessment. All patients were studied for Inferior vena cava collapsibility index (IVCCI), plasma atrial natriuretic peptide (ANP) concentration and Body composition monitor (BCM). Forty-four patients (77.3%) had non-hypovolemic and 16 (26.7%) had hypovolemic states. Plasma ANP levels didn’t differ between hypovolemic and non-hypovolemic subgroups. IVCCI was higher in hypovolemic group (p<0.001) with sensitivity 87.5% and specificity 81.8% for hypovolemia detection while BCM-over hydration (BCM-OH) values were higher in non-hypovolemic group (p=0.04) with sensitivity= 68.2% and specificity =75% for detection of hypervolemia. FeNa% showed negative significant correlation with IVCCI (r= -0.578, p <0.001) and positive significant correlation with BCM-OH (r= 0.33, p=0.018), while FeNa% showed non-significant correlation to plasma ANP concentration (p=0.25). Conclusion: Non-hypovolemic edema is more frequent in edematous INS children than hypovolemic states. IVCCI is a reliable non-invasive bedside tool for evaluating volume status in INS children and is superior to BCM while plasma ANP levels can’t discriminate type of edema in INS.


2017 ◽  
Vol 41 ◽  
pp. 130-137 ◽  
Author(s):  
Keith A. Corl ◽  
Naomi R. George ◽  
Justin Romanoff ◽  
Andrew T. Levinson ◽  
Darin B. Chheng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document