Abstract Objective Assessment of fluid responsiveness is problematic in intensive care unit patients. Lung recruitment maneuvers (LRM) can be used as a functional test to predict fluid responsiveness. We propose a new test to predict fluid responsiveness in mechanically ventilated patients by analyzing the variations in central venous pressure (CVP) and systemic arterial parameters during a prolonged sigh breath LRM without the use of a cardiac output measuring device. Design Prospective observational cohort study. Setting Intensive Care Unit, Saint-Etienne University Central Hospital. Patients Patients under mechanical ventilation, equipped with invasive arterial blood pressure, CVP, pulse contour analysis (PICCO™), requiring volume expansion, with no right ventricular dysfunction. Interventions. None. Measurements and main results CVP, systemic arterial parameters and stroke volume (SV) were recorded during prolonged LRM followed by a 500 mL fluid expansion to asses fluid responsiveness. 25 patients were screened and 18 patients analyzed. 9 patients were responders to volume expansion and 9 were not. Evaluation of hemodynamic parameters suggested the use of a linear regression model. Slopes for systolic arterial pressure, pulse pressure (PP), CVP and SV were all significantly different between responders and non-responders during the pressure increase phase of LRM (STEP-UP) (p = 0.022, p = 0.014, p = 0.006 and p = 0.038, respectively). PP and CVP slopes during STEP-UP were strongly predictive of fluid responsiveness with an AUC of 0.926 (95% CI, 0.78 to 1.00), sensitivity = 100%, specificity = 89% and an AUC = 0.901 (95% CI, 0.76 to 1.00), sensibility = 78%, specificity = 100%, respectively. Combining sensitivity of PP and specificity of CVP, prediction of fluid responsiveness can be achieved with 100% sensitivity and 100% specificity (AUC = 0.96; 95% CI, 0.90 to 1.00). One patient showed inconclusive values using the grey zone approach (5.5%). Conclusions In patients under mechanical ventilation with no right heart dysfunction, the association of PP and CVP slope analysis during a prolonged sigh breath LRM seems to offer a very promising method for prediction of fluid responsiveness without the use and associated cost of a cardiac output measurement device. Trial registration NCT04304521, IRBN902018/CHUSTE. Registered 11 March 2020, Fluid responsiveness predicted by a stepwise PEEP elevation recruitment maneuver in mechanically ventilated patients (STEP-PEEP)


Diagnostics ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 49
Author(s):  
Do-Wan Kim ◽  
Seungwoo Chung ◽  
Wu-Seong Kang ◽  
Joongsuck Kim

This systematic review and meta-analysis aimed to investigate the ultrasonographic variation of the diameter of the inferior vena cava (IVC), internal jugular vein (IJV), subclavian vein (SCV), and femoral vein (FV) to predict fluid responsiveness in critically ill patients. Relevant articles were obtained by searching PubMed, EMBASE, and Cochrane databases (articles up to 21 October 2021). The number of true positives, false positives, false negatives, and true negatives for the index test to predict fluid responsiveness was collected. We used a hierarchical summary receiver operating characteristics model and bivariate model for meta-analysis. Finally, 30 studies comprising 1719 patients were included in this review. The ultrasonographic variation of the IVC showed a pooled sensitivity and specificity of 0.75 and 0.83, respectively. The area under the receiver operating characteristics curve was 0.86. In the subgroup analysis, there was no difference between patients on mechanical ventilation and those breathing spontaneously. In terms of the IJV, SCV, and FV, meta-analysis was not conducted due to the limited number of studies. The ultrasonographic measurement of the variation in diameter of the IVC has a favorable diagnostic accuracy for predicting fluid responsiveness in critically ill patients. However, there was insufficient evidence in terms of the IJV, SCV, and FV.


2021 ◽  
Vol 50 (1) ◽  
pp. 751-751
Author(s):  
Sarah Walker ◽  
Kyle Honegger ◽  
Michael Carroll ◽  
Debra Weese-Mayer ◽  
L. Nelson Sanchez-Pinto

Author(s):  
Seon Ju Kim ◽  
So Yeon Kim ◽  
Hye Sun Lee ◽  
Goeun Park ◽  
Eun Jang Yoon ◽  
...  

Background: Dynamic preload indices may predict fluid responsiveness in end-stage liver disease. However, their usefulness in patients with altered vascular compliance is uncertain. This study is the first to evaluate whether dynamic indices can reliably predict fluid responsiveness in patients undergoing liver transplantation with a high femoral-to-radial arterial pressure gradient (PG).Methods: 80 liver transplant recipients were retrospectively categorized as having a normal (n = 56) or high (n = 24, difference in systolic pressure ≥ 10 mmHg and/or mean pressure ≥ 5 mmHg) femoral-to-radial arterial PG, measured immediately after radial and femoral arterial cannulation. The ability of dynamic preload indices (stroke volume variation, pulse pressure variation [PPV], pleth variability index) to predict fluid responsiveness was assessed before the surgery. Fluid replacement of 500 ml of crystalloid solution was performed over 15 min. Fluid responsiveness was defined as ≥ 15% increase in the stroke volume index. The area under the receiver-operating characteristic curve (AUC) indicated the prediction of fluid responsiveness.Results: Fourteen patients in the normal, and eight in the high PG group were fluid responders. The AUCs for PPV in the normal, high PG groups and total patients were 0.702 (95% confidence interval [CI] 0.553–0.851, P = 0.008), 0.633 (95% CI 0.384–0.881, P = 0.295) and 0.667 (95% CI 0.537–0.798, P = 0.012), respectively. No other index predicted fluid responsiveness.Conclusion: PPV can be used as a dynamic index of fluid responsiveness in patients with end-stage liver disease but not in patients with altered vascular compliance.


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
D F C Azevedo ◽  
R M Viera De Melo ◽  
A C Cunha ◽  
L G S Brito ◽  
T Viana ◽  
...  

Abstract Background It is known that in the immediate postoperative period of cardiac surgery, strict control of hemodynamic variables and blood volume is necessary, since there is an imbalance between oxygen supply and consumption. Thus, the present study seeks to validate methods previously used in different clinical situations to predict fluid responsiveness, in the current scenario of the immediate postoperative period of cardiac surgery. Purpose To evaluate the influence of “tidal volume challenge” from 6 ml / kg to 8 ml / kg of the predicted body weight (PBW) in conjunction with the end expiratory occlusion test (EEOT) in the variation of pulse pressure to predict fluid responsiveness in the immediate postoperative period of cardiac surgery. Methodology This prospective study included 30 patients after cardiac surgery. Hemodynamic and ventilatory parameters were initially recorded in mechanical ventilation at 6 ml/kg and after tidial volume challenge and with the EEOT at 8 ml/kg of predicted body weight (PBW). After recorded the intervention data, there was a return to ventilation at 6 ml/kg and a saline infusion of 500 ml was performed for 15 minutes. Fluid responsiveness was defined for patients who had an increase of 10% or more in velocity time integral (VTI) by echocardiogram after volume expansion compared to baseline value. Multivariate analysis was used to identify independent predictors of fluid response status. Sensitivity and specificity analyzes were performed to determine the predictive precision of each parameter. Results The main result of our study is that, when the tidal volume is increased from 6 to 8 ml/kg of PBW, the relative increase in pulse pressure variation (%ΔPPV6–8) predicts with excellent accuracy responsiveness to fluids with cut-off values of 18.3%, with sensitivity of 92.9% and specificity of 84% (P=0.019). Although changing PPV6, EEOT6 and EEOT8 are not reliable in predicting fluid responsiveness, they still require additional calculations. PPV8 also discriminates between responders and non-responders; however, with sensitivity (78.6%) and specificity (66.6%) when the value found in the PPV8 is up 8.5, but without statistical significance (figure). Conclusion The challenge of tidal volume and its influence on the ΔPP variation has excellent accuracy to predict fluid responsiveness in the immediate postoperative period of cardiac surgery. EEOT did not present good accuracy to predict fluid responsiveness in patients in the immediate postoperative period of cardiac surgery. FUNDunding Acknowledgement Type of funding sources: None.


2021 ◽  
Author(s):  
Sylvain VALLIER ◽  
Jean-Baptiste BOUCHET ◽  
Olivier DESEBBE ◽  
Camille FRANCOU ◽  
Darren RAPHAEL ◽  
...  

Abstract Objective:Assessment of fluid responsiveness is problematic in intensive care unit patients. Lung recruitment maneuvers (LRM) can be used as a functional test to predict fluid responsiveness. We propose a new test to predict fluid responsiveness in mechanically ventilated patients by analyzing the variations in central venous pressure (CVP) and systemic arterial parameters during a prolonged sigh breath LRM without the use of a cardiac output measuring device. Design:Prospective observational cohort study.Setting:Intensive Care Unit, Saint-Etienne University Central Hospital.Patients:Patients under mechanical ventilation, equipped with invasive arterial blood pressure, CVP, pulse contour analysis (PICCOTM), requiring volume expansion, with no right ventricular dysfunction.Interventions:None.Measurements and Main Results:CVP, systemic arterial parameters and stroke volume (SV) were recorded during prolonged LRM followed by a 500mL fluid expansion to asses fluid responsiveness. 25 patients were screened and 18 patients analyzed. 9 patients were responders to volume expansion and 9 were not. Evaluation of hemodynamic parameters suggested the use of a linear regression model. Slopes for systolic arterial pressure, pulse pressure (PP), CVP and SV were all significantly different between responders and non-responders during the pressure increase phase of LRM (STEP-UP) (p = 0.022, p = 0.014, p= 0.006 and p = 0.038, respectively). PP and CVP slopes during STEP-UP were strongly predictive of fluid responsiveness with an AUC of 0.926 (95% CI, 0.78 to 1.00), sensitivity = 100%, specificity = 89% and an AUC = 0.901 (95% CI, 0.76 to 1.00), sensibility = 78%, specificity = 100%, respectively. Combining sensitivity of PP and specificity of CVP, prediction of fluid responsiveness can be achieved with 100% sensitivity and 100% specificity (AUC=0.96; 95% CI, 0.90 to 1.00). One patient showed inconclusive values using the grey zone approach (5.5%).Conclusions:In patients under mechanical ventilation with no right heart dysfunction, the association of PP and CVP slope analysis during a prolonged sigh breath LRM seems to offer a very promising method for prediction of fluid responsiveness without the use and associated cost of a cardiac output measurement device.


PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0257737
Author(s):  
Clemence Roy ◽  
Gary Duclos ◽  
Cyril Nafati ◽  
Mickael Gardette ◽  
Alexandre Lopez ◽  
...  

Background An association was reported between the left ventricular longitudinal strain (LV-LS) and preload. LV-LS reflects the left cardiac function curve as it is the ratio of shortening over diastolic dimension. The aim of this study was to determine the sensitivity and specificity of LV-LS variations after a passive leg raising (PLR) maneuver to predict fluid responsiveness in intensive care unit (ICU) patients with acute circulatory failure (ACF). Methods Patients with ACF were prospectively included. Preload-dependency was defined as a velocity time integral (VTI) variation greater than 10% between baseline (T0) and PLR (T1), distinguishing the preload-dependent (PLD+) group and the preload-independent (PLD-) group. A 7-cycles, 4-chamber echocardiography loop was registered at T0 and T1, and strain analysis was performed off-line by a blind clinician. A general linear model for repeated measures was used to compare the LV-LS variation (T0 to T1) between the two groups. Results From June 2018 to August 2019, 60 patients (PLD+ = 33, PLD- = 27) were consecutively enrolled. The VTI variations after PLR were +21% (±8) in the PLD+ group and -1% (±7) in the PLD- group (p<0.01). Mean baseline LV-LS was -11.3% (±4.2) in the PLD+ group and -13.0% (±4.2) in the PLD- group (p = 0.12). LV-LS increased in the whole population after PLR +16.0% (±4.0) (p = 0.04). The LV-LS variations after PLR were +19.0% (±31) (p = 0.05) in the PLD+ group and +11.0% (±38) (p = 0.25) in the PLD- group, with no significant difference between the two groups (p = 0.08). The area under the curve for the LV-LS variations between T0 and T1 was 0.63 [0.48–0.77]. Conclusion Our study confirms that LV-LS is load-dependent; however, the variations in LV-LS after PLR is not a discriminating criterion to predict fluid responsiveness of ICU patients with ACF in this cohort.


2021 ◽  
Author(s):  
Yaru Li ◽  
Luyang Jiang ◽  
Yi Feng ◽  
Hai Ting ◽  
Guang Wang ◽  
...  

Abstract Background: The aim was to investigate the feasibility of the dynamic transesophageal echocardiographic parameters to predict fluid responsiveness in mechanically ventilated patients. Methods: In the prospective study, a total of 60 patients scheduled for elective general surgery under mechanical ventilation were enrolled. All patients received 10ml/kg Ringer’s lactate. The data including central venous pressure (CVP), cardiac index (CI), stroke volume variation (SVV), SVC-CI, E velocity, and the ratio of E/e’ was recorded before and after fluid challenge. Patients were classified as Responders (FR group) if their CI increased by at least 15% after fluid challenge. Results: 25/52(48%) were Responders and 27 were non-Responders (52%). The SVC-CI was higher in the Responders (41.90±11.48% vs 28.92±9.05%, P<0.01). SVC-CI was significantly correlated with △CI (r=0.568, P<0.01). The area under the ROC curve (AUROC) of SVC-CI was 0.838 (95% CI: 0.728~0.947, P<0.01) with the optimal cut-off value of 39.4% (sensitivity 64%, specificity 92.6%). The best cut-off value for SVV was 12.5% (sensitivity 40%, specificity 89%) with the AUROC of 0.68 (95% CI 0.53~0.826, P<0.05). Conclusion: The SVC-CI and SVV can predict fluid responsiveness effectively in mechanically ventilated patients. And SVC-CI is superior in predicting fluid responsiveness compared with SVV. Trial registration: Chinese Clinical Trial Registry, ChiCTR2000034940, Registered 25 July 2020, https://www.chictr.org.cn/index.aspx