scholarly journals Development and validation of bexarote by bioanalytical methods using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
K. Nagaraju ◽  
Y. A. Chowdary ◽  
M. V. Basaveswara Rao

Abstract Background The aim of this study was to develop and validate accurate and precise UPLC method with tandem mass spectrometry (Waters) for the determination of bexarotene in human plasma using bexarotene D4 as internal standard (IS). Results The retention time of bexarotene was 2.75 ± 0.30 min. The method was validated with respect to system suitability, linearity, accuracy, precision, matrix effect, auto sampler carryover test, and recovery. Linearity was found to be 1.04 to 351.93 μg/mL. LOQQC, LQC, INTQC, MQC, and HQC were found to be 1.0550, 2.7800, 25.2700, 131.61, and 263.23 respectively. The mean percentage recovery was found to be 95.72% Conclusion The bioanalytical method, a selective and sensitive liquid chromatography-mass spectrometry method to quantitate bexarotene in K2EDTA human plasma over the concentration range 1.0440 to 351.9320 ng/mL, was successfully validated. This method is suitable for sample analysis to support bioequivalence/bioavailability and/or pharmacokinetic studies involving formulations of bexarotene.

Author(s):  
Srikanth I ◽  
Prameela Rani A

Objective: This study was to develop and validate a liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the quantification of lenvatinib (LT) in human plasma.Methods: A simple, sensitive and specific LC–MS/MS method was developed for quantification of LT in human plasma using LTD4 as internal standard (IS). The analytical method consists of liquid–liquid extraction of plasma sample followed by the determination of LT by a LC–MS/MS. The analyte was separated on a Zorbax Eclipse XDB-C18 (150×4.6 mm, 5 μ) column with an isocratic mobile phase of acetontrile:0.1% formic acid (80:20 v/v) at a flow rate of 0.6 mL/minutes. The protonated ions were formed by a turbolon spray in a positive mode were used to detect analyte and IS. The MS/MS detection was made by monitoring the fragmentation of m/z 427.10→370.10 for LT and m/z 430.30→370.10 for IS on a MS.Result: The method was validated with the correlation coefficients of (r2) ≥0.995 over a linear concentration range of 10.20-501.60 pg/mL. This method demonstrated intra- and inter-day precision within 1.06-2.42% and 0.03-0.55% and accuracy within 95.64-100.08% and 97.16-100.07%.Conclusion: This method is suitable and convenient to pharmacokinetics and bioavailability studies for estimation of LT in biological samples by LC–MS/MS.


2014 ◽  
Vol 58 (6) ◽  
pp. 3481-3484 ◽  
Author(s):  
S. P. van Rijn ◽  
A. M. A. Wessels ◽  
B. Greijdanus ◽  
D. J. Touw ◽  
J. W. C. Alffenaar

ABSTRACTErtapenem, a carbapenem, relies on time-dependent killing. Therapeutic drug monitoring (TDM) should be considered, when ertapenem is used in specific populations, to achieve optimal bactericidal activity and optimize drug-dosing regimens. No validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported using deuterated ertapenem as the internal standard. A new simple and robust LC-MS/MS method using a quadrupole mass spectrometer was developed for analysis of ertapenem in human plasma, using deuterated ertapenem as the internal standard. The calibration curve was linear over a range of 0.1 (lower limit of quantification [LLOQ]) to 125 mg/liter. The calculated accuracy ranged from −2.4% to 10.3%. Within-run coefficients of variation (CV) ranged from 2.7% to 11.8%, and between-run CV ranged from 0% to 8.4%. Freeze-thaw stability had a bias of −3.3% and 0.1%. Storage of QC samples for 96 h at 4°C had a bias of −4.3 to 5.6%, storage at room temperature for 24 h had a bias of −10.7% to −14.8%, and storage in the autosampler had a bias between −2.9% and −10.0%. A simple LC-MS/MS method to quantify ertapenem in human plasma using deuterated ertapenem as the internal standard has been validated. This method can be used in pharmacokinetic studies and in clinical studies by performing TDM.


Molecules ◽  
2020 ◽  
Vol 25 (7) ◽  
pp. 1600 ◽  
Author(s):  
Essam Ezzeldin ◽  
Muzaffar Iqbal ◽  
Yousif A. Asiri ◽  
Azza A Ali ◽  
Prawez Alam ◽  
...  

Baricitinib, is a selective and reversible Janus kinase inhibitor, is commonly used to treat adult patients with moderately to severely active rheumatoid arthritis (RA). A fast, reproducible and sensitive method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantification of baricitinib in rat plasma has been developed. Irbersartan was used as the internal standard (IS). Baracitinib and IS were extracted from plasma by liquid–liquid extraction using a mixture of n-hexane and dichloromethane (1:1) as extracting agent. Chromatographic separation was performed using Acquity UPLC HILIC BEH 1.7 µm 2.1 × 50 mm column with the mobile phase consisting of 0.1% formic acid in acetonitrile and 20 mM ammonium acetate (pH 3) (97:3). The electrospray ionization in the positive-mode was used for sample ionization in the multiple reaction monitoring mode. Baricitinib and the IS were quantified using precursor-to-production transitions of m/z 372.15 > 251.24 and 429.69 > 207.35 for baricitinib and IS, respectively. The method was validated according to the recent FDA and EMA guidelines for bioanalytical method validation. The lower limit of quantification was 0.2 ng/mL, whereas the intra-day and inter-day accuracies of quality control (QCs) samples were ranged between 85.31% to 89.97% and 87.50% to 88.33%, respectively. Linearity, recovery, precision, and stability parameters were found to be within the acceptable range. The method was applied successfully applied in pilot pharmacokinetic studies.


2018 ◽  
Vol 25 (4) ◽  
pp. 372-380 ◽  
Author(s):  
Sireesha Dodda ◽  
Ajitha Makula ◽  
Srinivasa R Polagani ◽  
Raj N Kandhagatla

A method for bioanalysis of pentoxifylline in human plasma was developed using liquid chromatography–tandem mass spectrometry, which is simple, specific, and sensitive. Pentoxifylline D5 was used as the internal standard. Employing only 100 µl of human plasma, processing was done with solid-phase extraction technique. The analyte and the internal standard were separated from endogenous components on Ace phenyl column using a mixture of 5 mM ammonium acetate buffer and high performance liquid chromatography grade acetonitrile (60:40, v/v) as mobile phase at a flow rate of 1 ml/min. The linearity of the method was in the range of 3–1200 ng/ml with r2 > 0.99. Positive ion MRM mode was used for the detection of the analyte and the internal standard. The method was validated as per the US Food and Drug Administration guidelines and the results were within the acceptance limits. The proposed method was applied for comparative pharmacokinetic study of pentoxifylline after oral administration of 400 and 600 mg tablets to South Indian male subjects under fed conditions.