Seismic Evaluation of Existing Reinforced Concrete Building Columns

1996 ◽  
Vol 12 (4) ◽  
pp. 715-739 ◽  
Author(s):  
Abraham C. Lynn ◽  
Jack P. Moehle ◽  
Stephen A. Mahin ◽  
William T. Holmes

Past earthquakes have emphasized the vulnerability of reinforced concrete columns having details typical of those built before the mid-1970's. These columns are susceptible to axial-flexural, shear, and bond failures, which subsequently may lead to severe damage or collapse of the building. Research was undertaken to investigate the lateral and vertical load-resisting behavior of reinforced concrete columns typical of pre-1970's construction. Eight full-scale specimens were constructed and were loaded with constant axial load and increasing cyclic lateral displacement increments until failure. Test data are presented and compared with behavior estimated by using various evaluation methods.

2014 ◽  
Vol 17 (10) ◽  
pp. 1373-1385 ◽  
Author(s):  
Cao Thanh Ngoc Tran ◽  
Bing Li

This paper introduces an equation developed based on the strut-and-tie analogy to predict the shear strength of reinforced concrete columns with low transverse reinforcement ratios. The validity and applicability of the proposed equation are evaluated by comparison with available experimental data. The proposed equation includes the contributions from concrete and transverse reinforcement through the truss action, and axial load through the strut action. A reinforced concrete column with a low transverse reinforcement ratio, commonly found in existing structures in Singapore and other parts of the world was tested to validate the assumptions made during the development of the proposed equation. The column specimen was tested to failure under the combination of a constant axial load of 0.30 f' c A g and quasi-static cyclic loadings to simulate earthquake actions. The analytical results revealed that the proposed equation is capable of predicting the shear strength of reinforced concrete columns with low transverse reinforcement ratios subjected to reversed cyclic loadings to a satisfactory level of accuracy


Author(s):  
Hesham A. Haggag ◽  
Nagy F. Hanna ◽  
Ghada G. Ahmed

The axial strength of reinforced concrete columns is enhanced by wrapping them with Fiber Reinforced Polymers, FRP, fabrics.  The efficiency of such enhancement is investigated for columns when they are subjected to repeated lateral loads accompanied with their axial loading.  The current research presents that investigation for Glass and Carbon Fiber Reinforced Polymers (GFRP and CFRP) strengthening as well.  The reduction of axial loading capacity due to repeated loads is evaluated. The number of applied FRP plies with different types (GFRP or CFRP) are considered as parameters in our study. The study is evaluated experimentally and numerically.  The numerical investigation is done using ANSYS software. The experimental testing are done on five half scale reinforced concrete columns.  The loads are applied into three stages. Axial load are applied on specimen in stage 1 with a value of 30% of the ultimate column capacity. In stage 2, the lateral loads are applied in repeated manner in the existence of the vertical loads.  In the last stage the axial load is continued till the failure of the columns. The final axial capacities after applying the lateral action, mode of failure, crack patterns and lateral displacements are recorded.   Analytical comparisons for the analyzed specimens with the experimental findings are done.  It is found that the repeated lateral loads decrease the axial capacity of the columns with a ratio of about (38%-50%).  The carbon fiber achieved less reduction in the column axial capacity than the glass fiber.  The column confinement increases the ductility of the columns under the lateral loads.


Author(s):  
Ehab El-Salakawy ◽  
Fangxin Ye ◽  
Yasser Mostafa Selmy

Composite materials like glass fiber-reinforced polymer (GFRP) is becoming widely acceptable to be used as a reinforcing material due to its high ultimate tensile strength-to-weight ratio and excellent resistance to corrosion. However, the seismic behavior of GFRP-reinforced concrete columns has not been fully investigated yet. This paper presents the results of a numerical analysis of full-size GFRP-RC rectangular columns under cyclic loading. The simulated column depicts the lower part of a building column between the foundation and the point of contra-flexure at the mid-height of the column. GFRP reinforcement properties and concrete modeling based on fracture energy have been incorporated in the numerical model. Experimental validation has been used to examine the accuracy of the constructed finite element models (FEMs) using a commercially available software. The validated FEM was used to perform a parametric study, considering several concrete strength values and axial load levels, to study its influence on the performance of the GFRP-reinforced concrete columns under cyclic loading. It was concluded that the hysteretic dissipation capacity deteriorates under high axial load level due to severe softening of the concrete. The FE results showed a substantial improvement of the lateral load-carrying capacities by increasing concrete compressive strength.