Ferromagnetic resonance in plates with uniaxial and cubic anisotropy

Author(s):  
V.G. Shavrov ◽  
V.I. Shcheglov

New values have been obtained for the magnetoelastic coefficients h 3 and h 4 of nickel at room temperature from ferromagnetic resonance experiments on (100) single crystal nickel films. The ratios of h 3 / h 1 and h 4 / h 1 are found to be 0.091 ± 0.007 and 0.153 ± 0.015 respectively which give h 3 = (- 8.5 ± 0.7) x 10 -6 and h 4 = (- 14.3 ± 1.4) x 10 -6 if the Lee & Asgar value of h 3 is used (- 94 x 10 -6 ). The magnetocrystalline anisotropy constant K 1 , the saturation magnetization M and the spectroscopic splitting factor g have been measured also. It is found that K 1 = ( - 5.4 ± 0.3) x 10 4 erg/cm 3 and that g = 2.161 ± 0.009 in agreement with published data on bulk samples but that the value of M is found to be higher than the bulk value by 1.6%. The discrepancies between the values of h 3 , h 4 and M as reported here and the bulk values are discussed. The theory of feromagnetic resonance has been extended to cover the five-constant representation of magnetostriction and to the K 3 anisotropy term. The effect of the g factor having cubic anisotropy on the resonance conditions has been calculated.


1967 ◽  
Vol 92 (8) ◽  
pp. 583-619 ◽  
Author(s):  
A.Ya. Blank ◽  
M.I. Kaganov

2014 ◽  
Vol 59 (2) ◽  
pp. 141-147 ◽  
Author(s):  
A.Yu. Vidil ◽  
◽  
I.V. Zavislyak ◽  
M.O. Popov ◽  
◽  
...  

2018 ◽  
Vol 77 (3) ◽  
pp. 257-262
Author(s):  
А. S. Vakula ◽  
А. G. Belous ◽  
Т. V. Kalmykova ◽  
S. I. Petrushenko ◽  
V. N. Sukhov ◽  
...  

2014 ◽  
Vol 73 (8) ◽  
pp. 749-755 ◽  
Author(s):  
A. A. Girich ◽  
M.A. Miliaiev ◽  
S.B. Nedukh ◽  
A. Shuba ◽  
S. I. Tarapov

2017 ◽  
Author(s):  
Bo Tian ◽  
Peter Svedlindh ◽  
Mattias Strömberg ◽  
Erik Wetterskog

In this work, we demonstrate for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, <i>i.e.</i>, rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP) are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with an average coefficient of variation of 0.16%, which is superior to the performance of other reported RCA-based magnetic biosensors. For LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their co-precipitation with Mg<sub>2</sub>P<sub>2</sub>O<sub>7</sub> (a by-product of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.<br>


Sign in / Sign up

Export Citation Format

Share Document