Diffusion–Absorption Cycle

2016 ◽  
pp. 293-302
Author(s):  
CP Jawahar

This paper presents the energy analysis of a triple effect absorption compression (hybrid) cycle employing ammonia water as working fluid. The performance parameters such as cooling capacity and coefficient of performance of the hybrid cycle is analyzed by varying the temperature of evaporator from −10 °C to 10 °C, absorber and condenser temperatures in first stage from 25 °C to 45 °C, degassing width in both the stages from 0.02 to 0.12 and is compared with the conventional triple effect absorption cycle. The results of the analysis show that the maximum cooling capacity attained in the hybrid cycle is 472.3 kW, at 10 °C evaporator temperature and first stage degassing width of 0.12. The coefficient of performance of the hybrid cycle is about 30 to 65% more than the coefficient of performance of conventional triple effect cycle.


1993 ◽  
Vol 16 (4) ◽  
pp. 265-273 ◽  
Author(s):  
Lena Åhlby ◽  
David Hodgett ◽  
Reinhard Radermacher

Author(s):  
Noman Yousuf ◽  
Timothy Anderson ◽  
Roy Nates

Abstract Despite being identified nearly a century ago, the diffusion absorption refrigeration (DAR) cycle has received relatively little attention. One of the strongest attractions of the DAR cycle lies in the fact that it is thermally driven and does not require high value work. This makes it a prime candidate for harnessing low grade heat from solar collectors, or the waste heat from stationary generators, to produce cooling. However, to realize the benefits of the DAR cycle, there is a need to develop an improved understanding of how design parameters influence its performance. In this vein, this work developed a new parametric model that can be used to examine the performance of the DAR cycle for a range of operating conditions. The results showed that the cycle's performance was particularly sensitive to several factors: the rate of heat added and the temperature of the generator, the effectiveness of the gas and solution heat exchangers, the mass flowrate of the refrigerant and the type of the working fluid. It was shown that can deliver good performance at low generator temperatures if the refrigerant mass fraction in the strong solution is made as high as possible. Moreover, it was shown that a H2O-LiBr working pair could be useful for achieving cooling at low generator temperatures.


2019 ◽  
Vol 147 ◽  
pp. 537-544 ◽  
Author(s):  
Qingyu Xu ◽  
Ding Lu ◽  
Gaofei Chen ◽  
Hao Guo ◽  
Xueqiang Dong ◽  
...  

2015 ◽  
Vol 90 ◽  
pp. 820-830 ◽  
Author(s):  
Tao Cao ◽  
Hoseong Lee ◽  
Yunho Hwang ◽  
Reinhard Radermacher ◽  
Ho-Hwan Chun

Sign in / Sign up

Export Citation Format

Share Document