Air Separation by Polysulfone Hollow Fibre Membrane Permeators in Series

2000 ◽  
Vol 78 (8) ◽  
pp. 1066-1076 ◽  
Author(s):  
H.M.S. Lababidi
2015 ◽  
Vol 479 ◽  
pp. 232-239 ◽  
Author(s):  
Runze Wang ◽  
Bo Meng ◽  
Xiuxia Meng ◽  
Xiaoyao Tan ◽  
Jaka Sunarso ◽  
...  

RSC Advances ◽  
2016 ◽  
Vol 6 (92) ◽  
pp. 88943-88953 ◽  
Author(s):  
Pradeep K. Prajapati ◽  
Ankit M. Kansara ◽  
Puyam S. Singh

Simple preparation of a polydimethylsiloxane (PDMS) hollow fibre air separation membrane by a condensation reaction between the hydroxyl-end groups and hydride groups of polysiloxane reactants over a porous hollow fibre support.


2021 ◽  
Vol 1142 (1) ◽  
pp. 012011
Author(s):  
Suraya Najieha Kamarudin ◽  
Mohd Riduan Jamalludin ◽  
Siti Nor Suhaida Rasman ◽  
Siti Khadijah Hubadillah ◽  
Mohd Arif Budiman Pauzan ◽  
...  

1994 ◽  
Vol 17 (10) ◽  
pp. 543-548 ◽  
Author(s):  
Y.J. Gu ◽  
P.W. Boonstra ◽  
C. Akkerman ◽  
H. Mungroop ◽  
I. Tigchelaar ◽  
...  

The contact of blood with the artificial extracorporeal circuit causes a systemic inflammatory response due to blood activation. In this study, we compared two different paediatric membrane oxygenators used for extracorporeal circulation: a hollow fibre membrane oxygenator (Dideco Masterflo D-701, n=10), and a flat sheet silicone membrane oxygenator (Avecor Kolobow 800-2A, n=10). Blood compatibility was indicated by measuring complement activation as well as leukocyte and platelet activation. In patients perfused with a flat sheet membrane oxygenator, concentrations of complement split products C3a were significantly increased 30 minutes after the start of bypass (p<0.01), whereas only a mild increase of C3a was found in patients perfused with a hollow fibre membrane oxygenator. Leukocyte and platelet counts dropped uniformly in both groups after the start of bypass mainly due to hemodilution. Activation of leukocytes and platelets identified by both plasma β-glucuronidase and β-thromboglobulin was similar in both groups. Infants perfused with a flat sheet membrane oxygenator received significantly more donor blood than those perfused with a hollow fibre oxygenator (p<0.05). These results indicate that when used during paediatric cardiopulmonary bypass, a flat sheet membrane oxygenator has a higher complement activity than a hollow fibre membrane oxygenator, which is probably due to the relatively larger blood-surface contacting area of the oxygenator.


Author(s):  
Patricia Luis ◽  
Inmaculada Ortiz ◽  
Rubén Aldaco ◽  
Aurora Garea ◽  
Ángel Irabien

Removal of SO2 from gas emissions by selective absorption into a liquid is a common method to reduce air pollution and environmental risks. The absorption efficiency is determined by the interaction between the gases and the liquid. A great number of gas desulphurization methods have been developed where aqueous or organic solvents are used as sorbents.N,N-dimethylaniline (DMA) is an organic solvent used in the industry because its affinity with SO2. This absorption is neither too strong nor too weak, thus absorption and desorption can occur leading to a regenerative process where SO2 can be recovered. However, a direct contact between SO2 and DMA leads to several environmental problems caused by solvent evaporation and drops dragging into the gas stream.In order to increase the process efficiency and reduce environmental risks, a non-dispersive absorption process using hollow fibre membrane modules is developed in this work for a solvent zero emission process. The mass transfer into a fibre may be described by three main assumptions: gas-phase laminar flow, gas-phase plug-flow and gas-phase mixing. A numerical calculation was carried out to establish the performance of a hollow fibre membrane contactor for the removal of SO2 when water and N,N-dimethylaniline are used as sorbents in order to compare both, wetted and non-wetted operating modes.


Sign in / Sign up

Export Citation Format

Share Document