scholarly journals Pulmonary Vein Isolation in Patients With Paroxysmal Atrial Fibrillation After Direct Suture Closure of Congenital Atrial Septal Defect

2007 ◽  
Vol 71 (12) ◽  
pp. 1989-1992 ◽  
Author(s):  
Takumi Yamada ◽  
Hugh T. McElderry ◽  
Masahiro Muto ◽  
Yoshimasa Murakami ◽  
G. Neal Kay
Author(s):  
Meisam Mokhtari ◽  
Zahra Khajali ◽  
Mona Heidarali ◽  
Majid Haghjoo

Atrial fibrillation (AF) is the most commonly treated arrhythmia in clinical practice and is often found in association with an atrial septal defect (ASD). However, ASD closure rarely confers complete arrhythmia control. A 23-year-old man presented to our center with frequent episodes of palpitations. AF was documented in 12-lead electrocardiography, and echocardiography showed a secundum-type ASD, 14 mm in size, with a significant left-to-right shunt. ASD closure was performed successfully with an ASD occluder device with no residual shunting. During follow-up, the patient experienced several episodes of AF. Thirteen months after the ASD closure, cryoballoon pulmonary vein isolation was done successfully with no complications. During a 12-month follow-up, he had no symptoms or AF recurrences, and echocardiography showed no residual shunting. This study showed that cryoballoon pulmonary vein isolation could be performed successfully without residual shunts in patients with ASD closure devices.


2021 ◽  
Vol 28 ◽  
pp. 51-53
Author(s):  
I. A. Taymasova ◽  
M. V. Yashkov ◽  
M. V. Kadirova ◽  
E. A. Artyukhina

A case report of cryoballoon ablation for atrial fibrillation in a patient after atrial septal defect closure is presented. 


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Chikata ◽  
T Kato ◽  
K Ududa ◽  
S Fujita ◽  
K Otowa ◽  
...  

Abstract Introduction Pulmonary vein isolation (PVI) affects ganglionated plexi (GP) around the atrium, leading to a modification of the intrinsic cardiac autonomic system (ANS). In animal models, GP ablation has a potential risk of QT prolongation and ventricular arrhythmias. However, the impact of PVI on QT intervals in humans remains unclear. Purpose This study aims to evaluate the Impact of PVI on QT interval in patients with paroxysmal atrial fibrillation. Methods We analyzed consecutive 117 PAF patients for their first PVI procedures. 12-lead ECG was evaluated at baseline, 4 hr, day 1, 1 month, and 3 months after ablation. Only patients with sinus rhythm on 12-lead ECG at each evaluation point without antiarrhythmic drugs were included. Results Heart rate significantly increased at 4 hr, day 1, and 1 month. Raw QT interval prolonged at 4 hr (417.1±41.6 ms, P<0.001) but shortened at day 1 (376.4±34.1 ms, P<0.001), 1 month (382.2±31.5 ms, P<0.001), and 3 months (385.1±32.8 ms, P<0.001) compared to baseline (391.6±31.4 ms). Bazett- and Fridericia- corrected QTc intervals significantly prolonged at 4hr (Bazett: 430.8±27.9 ms, P<0.001; Fridericia: 425.8±27.4 ms, P<0.001), day1 (Bazett: 434.8±22.3 ms, P<0.001; Fridericia: 414.1±23.7 ms, P<0.001), 1M (Bazett: 434.8±22.3 ms, P<0.001; Fridericia: 408.2±21.0 ms, P<0.05), and 3M (Bazett: 420.1±21.8 ms, P<0.001; Fridericia: 407.8±21.1 ms, P<0.05) compared to baseline (Bazett: 404.9±25.2 ms; Fridericia: 400.0±22.6 ms). On the other hand, Framingham- and Hodges- corrected QTc interval significantly prolonged only at 4hr (Framingham: 424.1±26.6 ms, P<0.001; Hodges: 426.8±28.4 ms, P<0.001) and at day1 (Framingham: 412.3±29.3 ms, P<0.01; Hodges: 410.6±40.2 ms, P<0.05) compared to baseline (Framingham: 399.2±22.7 ms; Hodges: 400.7±22.8 ms). At 4 hr after ablation, raw QT and QTc of all formulas significantly prolonged than baseline. Raw QT and QTc prolongation at 4hr after ablation were more frequently observed in female patients. Multiple regression analysis revealed that female patient is a significant predictor of raw QT and QTc interval prolongation of all formulas 4hr after PVI. Conclusions Raw QT and QTc prolonged after PVI, especially in the acute phase. Female patient is a risk factor for QT prolongation in the acute phase after PVI. Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Author(s):  
Michelle Lycke ◽  
Maria Kyriakopoulou ◽  
Milad El Haddad ◽  
Jean-Yves Wielandts ◽  
Gabriela Hilfiker ◽  
...  

Abstract Aims Catheter ablation of paroxysmal atrial fibrillation (AF) reduces AF recurrence, AF burden, and improves quality of life. Data on clinical and procedural predictors of arrhythmia recurrence are scarce and are flawed by the high rate of pulmonary vein reconnection evidenced during repeat procedures after pulmonary vein isolation (PVI). In this study, we identified clinical and procedural predictors for AF recurrence 1 year after CLOSE-guided PVI, as this strategy has been associated with an increased PVI durability. Methods and results Patients with paroxysmal AF, who received CLOSE-guided PVI and who participated in a prospective trial in our centre, were included in this study. Uni- and multivariate models were plotted to find clinical and procedural predictors for AF recurrence within 1 year. Three hundred twenty-five patients with a mean age of 63 years (CHA2DS2VASc 1 [1–3], left atrium diameter 41 ± 6 mm) were included. About 60.9% were male individuals. After 1 year, AF recurrence occurred in 10.5% of patients. In a binary logistic regression analysis, the diagnosis-to-ablation time (DAT) was found to be the strongest predictor of AF recurrence (P = 0.011). Diagnosis-to-ablation time ≥1 year was associated with a nearly two-fold increased risk for developing AF recurrence. Conclusion The DAT is the most important predictor of arrhythmia recurrence in low-risk patients treated with durable pulmonary vein isolation for paroxysmal AF. Whether reducing the DAT could improve long-term outcomes should be investigated in another trial.


Sign in / Sign up

Export Citation Format

Share Document