Natural Speech Intelligibility in Theatres in Relation to Their Acoustics

2011 ◽  
Vol 18 (3-4) ◽  
pp. 293-311
Author(s):  
Maarten P.M. Luykx ◽  
Martijn L.S. Vercammen

There is a certain tendency in the design of theatres to make the halls quite large. From a perspective of natural speech intelligibility and strength of speech this is disadvantageous, because an actor's voice has a certain, limited loudness and consequently the signal-to-noise ratio at the listener may become too low. Based on the influence of signal/noise ratio on speech intelligibility, it is deduced that the strength G ≥ 6 dB and room volumes have to be limited to 4000–4500 m3 in order to maintain sufficient loudness for natural speech. Sound level measurements during performances with natural speech in a theatre have been performed, to determine background noise levels in the hall due to the audience and to investigate the signal-to-noise ratio of the actors voice at the audience. The background levels are mainly determined by installation noise and not by the influence of the audience.

2009 ◽  
Vol 20 (01) ◽  
pp. 028-039 ◽  
Author(s):  
Elizabeth M. Adams ◽  
Robert E. Moore

Purpose: To study the effect of noise on speech rate judgment and signal-to-noise ratio threshold (SNR50) at different speech rates (slow, preferred, and fast). Research Design: Speech rate judgment and SNR50 tasks were completed in a normal-hearing condition and a simulated hearing-loss condition. Study Sample: Twenty-four female and six male young, normal-hearing participants. Results: Speech rate judgment was not affected by background noise regardless of hearing condition. Results of the SNR50 task indicated that, as speech rate increased, performance decreased for both hearing conditions. There was a moderate correlation between speech rate judgment and SNR50 with the various speech rates, such that as judgment of speech rate increased from too slow to too fast, performance deteriorated. Conclusions: These findings can be used to support the need for counseling patients and their families about the potential advantages to using average speech rates or rates that are slightly slowed while conversing in the presence of background noise.


Perception ◽  
1995 ◽  
Vol 24 (4) ◽  
pp. 363-372 ◽  
Author(s):  
Johannes M Zanker

The subjective strength of a percept often depends on the stimulus intensity in a nonlinear way. Such coding is often reflected by the observation that the just-noticeable difference between two stimulus intensities (JND) is proportional to the absolute stimulus intensity. This behaviour, which is usually referred to as Weber's Law, can be interpreted as a compressive nonlinearity extending the operating range of a sensory system. When the noise superimposed on a motion stimulus is increased along a logarithmic scale (in order to provide linear steps in subjective difference) in motion-coherency measurements, observers often report that the subjective differences between the various noise levels increase together with the absolute level. This observation could indicate a deviation from Weber's Law for variation of motion strength as obtained by changing the signal-to-noise ratio in random-dot kinematograms. Thus JNDs were measured for the superposition of uncorrelated random-dot patterns on static random-dot patterns and three types of motion stimuli realised as random-dot kinematograms, namely large-field and object ‘Fourier’ motion (all or a group of dots move coherently), ‘drift-balanced’ motion (a travelling region of static dots), and paradoxical ‘theta’ motion (the dots on the surface of an object move in opposite direction to the object itself). For all classes of stimuli, the JNDs when expressed as differences in signal-to-noise ratio turned out to increase with the signal-to-noise ratio, whereas the JNDs given as percentage of superimposed noise appear to be similar for all tested noise levels. Thus motion perception is in accordance with Weber's Law when the signal-to-noise ratio is regarded as stimulus intensity, which in turn appears to be coded in a nonlinear fashion. In general the Weber fractions are very large, indicating a poor differential sensitivity in signal-to-noise measurements.


2020 ◽  
Vol 24 ◽  
pp. 233121652097034
Author(s):  
Florian Langner ◽  
Andreas Büchner ◽  
Waldo Nogueira

Cochlear implant (CI) sound processing typically uses a front-end automatic gain control (AGC), reducing the acoustic dynamic range (DR) to control the output level and protect the signal processing against large amplitude changes. It can also introduce distortions into the signal and does not allow a direct mapping between acoustic input and electric output. For speech in noise, a reduction in DR can result in lower speech intelligibility due to compressed modulations of speech. This study proposes to implement a CI signal processing scheme consisting of a full acoustic DR with adaptive properties to improve the signal-to-noise ratio and overall speech intelligibility. Measurements based on the Short-Time Objective Intelligibility measure and an electrodogram analysis, as well as behavioral tests in up to 10 CI users, were used to compare performance with a single-channel, dual-loop, front-end AGC and with an adaptive back-end multiband dynamic compensation system (Voice Guard [VG]). Speech intelligibility in quiet and at a +10 dB signal-to-noise ratio was assessed with the Hochmair–Schulz–Moser sentence test. A logatome discrimination task with different consonants was performed in quiet. Speech intelligibility was significantly higher in quiet for VG than for AGC, but intelligibility was similar in noise. Participants obtained significantly better scores with VG than AGC in the logatome discrimination task. The objective measurements predicted significantly better performance estimates for VG. Overall, a dynamic compensation system can outperform a single-stage compression (AGC + linear compression) for speech perception in quiet.


2002 ◽  
Vol 13 (01) ◽  
pp. 038-049 ◽  
Author(s):  
Gabrielle H. Saunders ◽  
Kathleen M. Cienkowski

Measurement of hearing aid outcome is particularly difficult because there are numerous dimensions to consider (e.g., performance, satisfaction, benefit). Often there are discrepancies between scores in these dimensions. It is difficult to reconcile these discrepancies because the materials and formats used to measure each dimension are so very different. We report data obtained with an outcome measure that examines both objective and subjective dimensions with the same test format and materials and gives results in the same unit of measurement (signal-to-noise ratio). Two variables are measured: a “performance” speech reception threshold and a “perceptual” speech reception threshold. The signal-to-noise ratio difference between these is computed to determine the perceptual-performance discrepancy (PPDIS). The results showed that, on average, 48 percent of the variance in subjective ratings of a hearing aid could be explained by a combination of the performance speech reception threshold and the PPDIS. These findings suggest that the measure is potentially a valuable clinical tool.


Geophysics ◽  
2009 ◽  
Vol 74 (6) ◽  
pp. V133-V141 ◽  
Author(s):  
J. Wang ◽  
F. Tilmann ◽  
R. S. White ◽  
P. Bordoni

Hydraulic fracture-induced microseismic events in producing oil and gas fields are usually small, and noise levels are high at the surface as a result of the heavy equipment in use. Similarly, in nonhydrocarbon settings, arrays for detecting local earthquakes will benefit from reduced noise levels and the ability to detect smaller events will be increased. We propose a frequency-dependent multichannel Wiener filtering technique with linear constraints that uses an adaptive least-squares method to remove coherent noise in seismic array data. The noise records on several reference channels are used to predict the noise on a primary channel and then can be subtracted from the observed data. On a test with an unconstrained version of this filter, maximal noise suppression leads to signal distortion. Two methods of im-posing constraints then achieve signal preservation. In one case study, synthetic signals are added to noise from a pilot deployment of a hexagonal array (nine three-component seismometers, approximately [Formula: see text]) above a gas field; noise levels are suppressed by up to [Formula: see text] (at [Formula: see text]). In a second case study, natural seismicity recorded at a dense array ([Formula: see text] spacing) in Italy is used, where the application of the filter improves the signal-to-noise ratio (S/N) more than [Formula: see text] (at [Formula: see text]) using 35 stations. In both cases, the performance of the multichannel Wiener filters is significantly better than stacking, espe-cially at lower frequencies where stacking does not help to suppress the coherent noise. The unconstrained version of the filter yields the best improvement in signal-to-noise ratio, but the constrained filter is useful when waveform distortion is unacceptable.


2012 ◽  
Vol 126 (10) ◽  
pp. 1010-1015 ◽  
Author(s):  
V Possamai ◽  
G Kirk ◽  
A Scott ◽  
D Skinner

AbstractObjectives:To assess the feasibility of designing and implementing a speech in noise test in children before and after grommet insertion, and to analyse the results of such a test in a small group of children.Methods:Twelve children aged six to nine years who were scheduled to undergo grommet insertion were identified. They underwent speech in noise testing before and after grommet insertion. This testing used Arthur Boothroyd word lists read at 60 dB in four listening conditions presented in a sound field: firstly in quiet conditions, then in signal to noise ratios of +10 (50 dB background noise), 0 (60 dB) and −10 (70 dB).Results:Mean phoneme scores were: in quiet conditions, 28.1 pre- and 30 post-operatively (p = 0.04); in 50 dB background noise (signal to noise ratio +10), 24.2 pre- and 29 post-operatively (p < 0.01); in 60 dB background noise (signal to noise ratio 0), 22.6 pre- and 27.5 post-operatively (p = 0.06); and in 70 dB background noise (signal to noise ratio −10), 13.9 pre- and 21 post-operatively (p = 0.05).Conclusion:This small study suggests that speech in noise testing is feasible in this scenario. Our small group of children demonstrated a significant improvement in speech in noise scores following grommet insertion. This is likely to translate into a significant advantage in the educational environment.


2018 ◽  
Vol 7 (4.10) ◽  
pp. 202
Author(s):  
T. S. Arulananth ◽  
R. Satheesh ◽  
P. Bhaskara Reddy

The primary inspiration of our work is to discovering upgrades in the current Compressed Sensing procedure that utilizations Non Adaptive Projection Matrix rule. Normal Frame Signal-to-Noise Ratio (AFSNR) is intended to evaluate the show of the Frame-Based Adaptive Compressed Sensing with the Non-Adaptive Compressed Sensing (CS). It is a developing sign securing strategy and straight gathers the signs in a compacted shape on the off chance that they are meager on some specific premise. Proposed approach utilizes Adaptive Projection Matrix in light of edge examination which gives fundamentally enhanced discourse recreation quality and decreases the noise levels.


Sign in / Sign up

Export Citation Format

Share Document