Effects of Speech Rate, Background Noise, and Simulated Hearing Loss on Speech Rate Judgment and Speech Intelligibility in Young Listeners

2009 ◽  
Vol 20 (01) ◽  
pp. 028-039 ◽  
Author(s):  
Elizabeth M. Adams ◽  
Robert E. Moore

Purpose: To study the effect of noise on speech rate judgment and signal-to-noise ratio threshold (SNR50) at different speech rates (slow, preferred, and fast). Research Design: Speech rate judgment and SNR50 tasks were completed in a normal-hearing condition and a simulated hearing-loss condition. Study Sample: Twenty-four female and six male young, normal-hearing participants. Results: Speech rate judgment was not affected by background noise regardless of hearing condition. Results of the SNR50 task indicated that, as speech rate increased, performance decreased for both hearing conditions. There was a moderate correlation between speech rate judgment and SNR50 with the various speech rates, such that as judgment of speech rate increased from too slow to too fast, performance deteriorated. Conclusions: These findings can be used to support the need for counseling patients and their families about the potential advantages to using average speech rates or rates that are slightly slowed while conversing in the presence of background noise.

2006 ◽  
Vol 17 (03) ◽  
pp. 157-167 ◽  
Author(s):  
Rachel A. McArdle ◽  
Richard H. Wilson

The purpose of this study was to determine the list equivalency of the 18 QuickSIN™ (Quick Speech in Noise test) lists. Individuals with normal hearing (n = 24) and with sensorineural hearing loss (n = 72) were studied. Mean recognition performances on the 18 lists by the listeners with normal hearing were 2.8 to 4.3 dB SNR (signal-to-noise ratio), whereas the range was 10.0 to 14.3 dB SNR for the listeners with hearing loss. The psychometric functions for each list showed high performance variability across lists for listeners with hearing loss but not for listeners with normal hearing. For listeners with hearing loss, Lists 4, 5, 13, and 16 fell outside of the critical difference. The data from this study suggest nine lists that provide homogenous results for listeners with and without hearing loss. Finally, there was an 8.7 dB difference in performances between the two groups indicating a more favorable signal-to-noise ratio required by the listeners with hearing loss to obtain equal performance.


2020 ◽  
Author(s):  
Tom Gajęcki ◽  
Waldo Nogueira

Normal hearing listeners have the ability to exploit the audio input perceived by each ear to extract target information in challenging listening scenarios. Bilateral cochlear implant (BiCI) users, however, do not benefit as much as normal hearing listeners do from a bilateral input. In this study, we investigate the effect that bilaterally linked band selection, bilaterally synchronized electrical stimulation and ideal binary masks (IdBMs) have on the ability of 10 BiCIs to understand speech in background noise. The performance was assessed through a sentence-based speech intelligibility test, in a scenario where the speech signal was presented from the front and the interfering noise from one side. The linked band selection relies on the most favorable signal-to-noise-ratio (SNR) ear, which will select the bands to be stimulated for both CIs. Results show that no benefit from adding a second CI to the most favorable SNR side was achieved for any of the tested bilateral conditions. However, when using both devices, speech perception results show that performing linked band selection, besides delivering bilaterally synchronized electrical stimulation, leads to an improvement compared to standard clinical setups. Moreover, the outcomes of this work show that by applying IdBMs, subjects achieve speech intelligibility scores similar to the ones without background noise.


2011 ◽  
Vol 18 (3-4) ◽  
pp. 293-311
Author(s):  
Maarten P.M. Luykx ◽  
Martijn L.S. Vercammen

There is a certain tendency in the design of theatres to make the halls quite large. From a perspective of natural speech intelligibility and strength of speech this is disadvantageous, because an actor's voice has a certain, limited loudness and consequently the signal-to-noise ratio at the listener may become too low. Based on the influence of signal/noise ratio on speech intelligibility, it is deduced that the strength G ≥ 6 dB and room volumes have to be limited to 4000–4500 m3 in order to maintain sufficient loudness for natural speech. Sound level measurements during performances with natural speech in a theatre have been performed, to determine background noise levels in the hall due to the audience and to investigate the signal-to-noise ratio of the actors voice at the audience. The background levels are mainly determined by installation noise and not by the influence of the audience.


1995 ◽  
Vol 38 (5) ◽  
pp. 1150-1156 ◽  
Author(s):  
Sandra Gordon-Salant ◽  
Peter J. Fitzgibbons

This study investigated the hypothesis that age effects exert an increased influence on speech recognition performance as the number of acoustic degradations Of the speech signal increases. Four groups participated: young listeners with normal hearing, elderly listeners with normal hearing, young listeners with hearing loss, and elderly listeners with hearing loss. Recognition was assessed for sentence materials degraded by noise, reverberation, or time compression, either in isolation or in binary combinations. Performance scores were converted to an equivalent signal-to-noise ratio index to facilitate direct comparison of the effects of different forms of stimulus degradation. Age effects were observed primarily in multiple degradation conditions featuring time compression of the stimuli. These results are discussed in terms of a postulated change in functional signal-to-noise ratio with increasing age.


2012 ◽  
Vol 23 (08) ◽  
pp. 590-605 ◽  
Author(s):  
Richard H. Wilson ◽  
Rachel McArdle ◽  
Kelly L. Watts ◽  
Sherri L. Smith

Background: The Revised Speech Perception in Noise Test (R-SPIN; Bilger, 1984b) is composed of 200 target words distributed as the last words in 200 low-predictability (LP) and 200 high-predictability (HP) sentences. Four list pairs, each consisting of two 50-sentence lists, were constructed with the target word in a LP and HP sentence. Traditionally the R-SPIN is presented at a signal-to-noise ratio (SNR, S/N) of 8 dB with the listener task to repeat the last word in the sentence. Purpose: The purpose was to determine the practicality of altering the R-SPIN format from a single SNR paradigm into a multiple SNR paradigm from which the 50% points for the HP and LP sentences can be calculated. Research Design: Three repeated measures experiments were conducted. Study Sample: Forty listeners with normal hearing and 184 older listeners with pure-tone hearing loss participated in the sequence of experiments. Data Collection and Analysis: The R-SPIN sentences were edited digitally (1) to maintain the temporal relation between the sentences and babble, (2) to establish the SNRs, and (3) to mix the speech and noise signals to obtain SNRs between –1 and 23 dB. All materials were recorded on CD and were presented through an earphone with the responses recorded and analyzed at the token level. For reference purposes the Words-in-Noise Test (WIN) was included in the first experiment. Results: In Experiment 1, recognition performances by listeners with normal hearing were better than performances by listeners with hearing loss. For both groups, performances on the HP materials were better than performances on the LP materials. Performances on the LP materials and on the WIN were similar. Performances at 8 dB S/N were the same with the traditional fixed level presentation and the descending presentation level paradigms. The results from Experiment 2 demonstrated that the four list pairs of R-SPIN materials produced good first approximation psychometric functions over the –4 to 23 dB S/N range, but there were irregularities. The data from Experiment 2 were used in Experiment 3 to guide the selection of the words to be used at the various SNRs that would provide homogeneous performances at each SNR and would produce systematic psychometric functions. In Experiment 3, the 50% points were in good agreement for the LP and HP conditions within both groups of listeners. The psychometric functions for List Pairs 1 and 2, 3 and 4, and 5 and 6 had similar characteristics and maintained reasonable separations between the HP and LP functions, whereas the HP and LP functions for List Pair 7 and 8 bisected one another at the lower SNRs. Conclusions: This study indicates that the R-SPIN can be configured into a multiple SNR paradigm. A more in-depth study with the R-SPIN materials is needed to develop lists that are systematic and reasonably equivalent for use on listeners with hearing loss. The approach should be based on the psychometric characteristics of the 200 HP and 200 LP sentences with the current R-SPIN lists discarded. Of importance is maintaining the synchrony between the sentences and their accompanying babble.


2020 ◽  
Vol 24 ◽  
pp. 233121652097034
Author(s):  
Florian Langner ◽  
Andreas Büchner ◽  
Waldo Nogueira

Cochlear implant (CI) sound processing typically uses a front-end automatic gain control (AGC), reducing the acoustic dynamic range (DR) to control the output level and protect the signal processing against large amplitude changes. It can also introduce distortions into the signal and does not allow a direct mapping between acoustic input and electric output. For speech in noise, a reduction in DR can result in lower speech intelligibility due to compressed modulations of speech. This study proposes to implement a CI signal processing scheme consisting of a full acoustic DR with adaptive properties to improve the signal-to-noise ratio and overall speech intelligibility. Measurements based on the Short-Time Objective Intelligibility measure and an electrodogram analysis, as well as behavioral tests in up to 10 CI users, were used to compare performance with a single-channel, dual-loop, front-end AGC and with an adaptive back-end multiband dynamic compensation system (Voice Guard [VG]). Speech intelligibility in quiet and at a +10 dB signal-to-noise ratio was assessed with the Hochmair–Schulz–Moser sentence test. A logatome discrimination task with different consonants was performed in quiet. Speech intelligibility was significantly higher in quiet for VG than for AGC, but intelligibility was similar in noise. Participants obtained significantly better scores with VG than AGC in the logatome discrimination task. The objective measurements predicted significantly better performance estimates for VG. Overall, a dynamic compensation system can outperform a single-stage compression (AGC + linear compression) for speech perception in quiet.


2018 ◽  
Vol 39 (5) ◽  
pp. 958-968 ◽  
Author(s):  
Greg D. Watkins ◽  
Brett A. Swanson ◽  
Gregg J. Suaning

2004 ◽  
Vol 116 (4) ◽  
pp. 2395-2405 ◽  
Author(s):  
Mead C. Killion ◽  
Patricia A. Niquette ◽  
Gail I. Gudmundsen ◽  
Lawrence J. Revit ◽  
Shilpi Banerjee

2002 ◽  
Vol 13 (01) ◽  
pp. 038-049 ◽  
Author(s):  
Gabrielle H. Saunders ◽  
Kathleen M. Cienkowski

Measurement of hearing aid outcome is particularly difficult because there are numerous dimensions to consider (e.g., performance, satisfaction, benefit). Often there are discrepancies between scores in these dimensions. It is difficult to reconcile these discrepancies because the materials and formats used to measure each dimension are so very different. We report data obtained with an outcome measure that examines both objective and subjective dimensions with the same test format and materials and gives results in the same unit of measurement (signal-to-noise ratio). Two variables are measured: a “performance” speech reception threshold and a “perceptual” speech reception threshold. The signal-to-noise ratio difference between these is computed to determine the perceptual-performance discrepancy (PPDIS). The results showed that, on average, 48 percent of the variance in subjective ratings of a hearing aid could be explained by a combination of the performance speech reception threshold and the PPDIS. These findings suggest that the measure is potentially a valuable clinical tool.


Sign in / Sign up

Export Citation Format

Share Document