Post-implantation pacemaker complications: the nurse's role in management

2014 ◽  
Vol 9 (12) ◽  
pp. 592-598 ◽  
Author(s):  
Sarah Jane Palmer
Author(s):  
John H. L. Watson ◽  
John L. Swedo ◽  
M. Vrandecic

The ambient temperature and the nature of the storage fluids may well have significant effects upon the post-implantation behavior of venus autografts. A first step in the investigation of such effects is reported here. Experimental conditions have been set which approximate actual operating room procedures. Saphenous veins from dogs have been used as models in the experiments. After removal from the dogs the veins were kept for two hours under four different experimental conditions, viz at either 4°C or 23°C in either physiological saline or whole canine arterial blood. At the end of the two hours they were prepared for light and electron microscopy. Since no obvious changes or damage could be seen in the veins by light microscopy, even with the advantage of tissue specific stains, it was essential that the control of parameters for successful grafts be set by electron microscopy.


Author(s):  
C. O. Jung ◽  
S. J. Krause ◽  
S.R. Wilson

Silicon-on-insulator (SOI) structures have excellent potential for future use in radiation hardened and high speed integrated circuits. For device fabrication in SOI material a high quality superficial Si layer above a buried oxide layer is required. Recently, Celler et al. reported that post-implantation annealing of oxygen implanted SOI at very high temperatures would eliminate virtually all defects and precipiates in the superficial Si layer. In this work we are reporting on the effect of three different post implantation annealing cycles on the structure of oxygen implanted SOI samples which were implanted under the same conditions.


2010 ◽  
Vol 6 (3) ◽  
pp. 87
Author(s):  
Niraj Varma ◽  

The use of implantable electronic cardiac devices is increasing. Post-implantation follow-up is important for monitoring both device function and patient condition; however, clinical practice is inconsistent. For example, implantable cardioverter–defibrillator follow-up schedules vary from every three months to yearly according to facility and physician preference and the availability of resources. Importantly, no surveillance occurs between follow-up visits. By contrast, implantable devices with automatic remote monitoring capability provide a means for performing constant surveillance, with the ability to identify salient problems rapidly. The Lumos-T Reduces Routine Office Device Follow-up Study (TRUST) demonstrated that remote home monitoring reduced clinic burden and allowed early detection of patient and/or system problems, enabling efficient monitoring and an opportunity to enhance patient safety. The results of the trial have significant implications for the management of patients receiving all forms of implantable electronic cardiac device.


1991 ◽  
Vol 223 ◽  
Author(s):  
Qin Fuguang ◽  
Yao Zhenyu ◽  
Ren Zhizhang ◽  
S.-T. Lee ◽  
I. Bello ◽  
...  

ABSTRACTDirect ion beam deposition of carbon films on silicon in the ion energy range of 15–500eV and temperature range of 25–800°C has been studied using mass selected C+ ions under ultrahigh vacuum. The films were characterized with X-ray photoelectron spectroscopy, Raman spectroscopy, and transmission electron microscopy and diffraction analysis. Films deposited at room temperature consist mainly of amorphous carbon. Deposition at a higher temperature, or post-implantation annealing leads to formation of microcrystalline graphite. A deposition temperature above 800°C favors the formation of microcrystalline graphite with a preferred orientation in the (0001) direction. No evidence of diamond formation was observed in these films.


2004 ◽  
Vol 82 ◽  
pp. S189-S190
Author(s):  
S.P. Gonçalves ◽  
D. Dozortsev ◽  
V. Abdelmassih ◽  
F.G. Oliveira ◽  
P.T. Salgueiro ◽  
...  

2005 ◽  
Vol 4 (3) ◽  
pp. 91
Author(s):  
P.R. De Jong ◽  
P. Radziszewski ◽  
P. Dobronski ◽  
A. Borkowski ◽  
M. Cervgni ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document