scholarly journals Minimally invasive excision of gynaecomastia – a novel and effective surgical technique

2010 ◽  
Vol 92 (3) ◽  
pp. 198-200 ◽  
Author(s):  
O Qutob ◽  
B Elahi ◽  
V Garimella ◽  
N Ihsan ◽  
PJ Drew

INTRODUCTION More aesthetically acceptable treatment options have been sought to minimise the morbidity associated with open surgery for gynaecomastia. This study investigated the use of a vacuum-assisted biopsy device (VABD) and liposuction to provide minimally invasive approach. PATIENTS AND METHODS Patients diagnosed with idiopathic benign gynaecomastia referred to the Breast Care Unit of Castle Hill Hospital between June 2002 and April 2007 and requesting surgical intervention underwent VABD excision and liposuction. All patients underwent thorough investigations to exclude any underlying cause for their gynaecomastia. The procedure was carried out by a single consultant surgeon with special interest in breast surgery. An 8-G mammotome probe was advanced through a 4-mm incision positioned in the corresponding anterior axillary line to excise the glandular disc. Liposuction was performed through the same incision. Incision wounds were closed with Steristrips. A pressure dressing was applied over wound by corset and an inflatable device. RESULTS Thirty-six male patients with grade I and II gynaecomastia were recruited (22 bilateral, 14 unilateral). Average age was 33.3 years (range, 16–88 years). All underwent mammotome excision and liposuction. There were no conversions to an open procedure. The average procedure time was 50.3 min (range, 30–80 min). One intra-operative complication was recorded. The minimum follow-up time was 2 months. Thirty-four patients reported excellent satisfaction, two patients had residual gynaecomastia and needed a re-do procedure. Three patients developed small haematomas that resolved spontaneously. CONCLUSION This novel, minimally invasive, surgical approach for gynaecomastia gives excellent results with minimal morbidity.

2008 ◽  
Vol 139 (2_suppl) ◽  
pp. P135-P136
Author(s):  
Michael J Clark ◽  
Phillip Pellitteri

Objectives 1) Delineate the role of CT-technetium 99m sestamibi (CT-MIBI) fusion in directed parathyroidectomy. 2) Determine the clinical situations where CT-MIBI fusion would be strongly recommended. Methods Charts from 190 patients with primary hyperparathyroidism who underwent CT-MIBI mage fusion as a part of a scan directed, minimally invasive parathyroid exploration protocol were reviewed. The results of conventional sestamibi imaging and CT-MIBI image fusion were compared with operative findings. Results CT-MIBI image fusion accurately localized solitary hyperfunctional parathyroid glands in 70% of patients imaged; 55% of patients were localized with conventional sestamibi imaging. CT-MIBI fusion imaging was most accurate and predictive when conventional images suggested that the solitary gland was separated from the thyroid or when the adenoma was located in the retro-thyroidal/ retro-esophageal plane or mediastinum. Conclusions CT-MIBI image fusion is not superior to conventional sestamibi imaging when utilized for routine localization of hyperfunctional parathyroid glands. CT-MIBI fusion is of greatest benefit in guiding the directed approach to solitary glands, which are separate from the thyroid or ectopically located, regions where conventional imaging has proven to be less accurate. This imaging technique will augment the minimally invasive surgical approach in selected patients with primary hyperparathyroidism in order to further refine the focused technique. Its utility as the standard preoperative localization modality is not yet established and requires further investigation. Evaluation of differences in facility utilization with CT-MIBI image fusion and conventional sestamibi imaging may be helpful in determining its role in preoperative localization for hyperparathyroidism.


2021 ◽  
Vol 37 (5) ◽  
pp. e276-e289
Author(s):  
Kelly Maria Moreira ◽  
Luiz Eduardo Bertassoni ◽  
Robert Phill Davies ◽  
Felipe Joia ◽  
José Francisco Höfling ◽  
...  

2016 ◽  
Vol 37 (12) ◽  
pp. 1333-1342 ◽  
Author(s):  
Prashant N. Gedam ◽  
Faizaan M. Rushnaiwala

Background: The objective of this study was to report the results of a new minimally invasive Achilles reconstruction technique and to assess the perioperative morbidity, medium- to long-term outcomes, and functional results. Methods: Our series was comprised 14 patients (11 men and 3 women), with a mean age of 45.6 years at surgery. Each patient had a chronic Achilles tendon rupture. The mean interval from rupture to surgery was 5.5 months (range, 2-10). The mean total follow-up was 30.1 months (range, 12-78). All patients were operated with a central turndown flap augmented with free semitendinosus tendon graft and percutaneous sutures in a minimally invasive approach assisted by endoscopy. The patients underwent retrospective assessment by clinical examination, the American Orthopaedic Foot & Ankle Society (AOFAS) ankle and hindfoot score, and the Achilles Tendon Total Rupture Score (ATRS). Paired t tests were used to assess the preoperative and postoperative AOFAS scores, ATRS scores, and ankle range of motion. Results: The length of the defect ranged from 3 to 8 cm (mean, 5.1), while the length of the turndown flap ranged from 8 to 13 cm (mean, 10.1). The mean AOFAS score improved from 64.5 points preoperatively to 96.9 points at last follow-up. The mean ATRS score improved from 49.4 preoperatively to 91.4 points at last follow-up. None of the patients developed a wound complication. No patient had a rerupture or sural nerve damage. Conclusion: All patients in our study had a favorable outcome with no complications. We believe that with this triple-repair technique, one can achieve a strong and robust repair such as in open surgery while at the same time reducing the incidence of complications. Level of Evidence: Level III, retrospective comparative study.


2021 ◽  
Author(s):  
Ugur Unsal ◽  
Huri Sabur ◽  
Mehmet Soyler

Abstract Purpose: To describe a novel surgical technique for iridodialysis repair using iris retractor segments and report its clinical results.Methods: 53 eyes of 53 patients who underwent surgery for iridodialysis repair were enrolled in this retrospective study. Data recorded from patient files consisted of age, sex, history of trauma, surgical indications and type of surgery, preoperative and postoperative corrected distance visual acuity (CDVA), intraocular pressure (IOP), complications, and follow-up time. The novel, minimally invasive surgical technique was explicitly described in detail.Results: Mean follow-up time was 34.4 (range 12-84) months. The subjects were 29 (54.7%) men and 26 (45.3%) women, and the mean age was 56.6±14.0 years. Iridodialysis repair performed using one segment in 37 (69.8%) eyes, two segments in 15 (28.3%) eyes, and three segments in 1 (1.9%) eye. Pupilloplasty was performed in 17 eyes due to wide pupil diameter. The iridodialysis repair was combined with lens removal in 48 eyes, and anterior vitrectomy was performed in 10 eyes. CDVA significantly improved after surgery (p<0.001). Post-traumatic IOP rise was the most common complication, and six patients needed medical therapy for glaucoma control.Conclusion: Iridodialysis repair using iris retractor segment is a minimally invasive technique and found to be safe and effective, providing less surgical manipulation and surgical time than other techniques.


2021 ◽  
Vol 8 ◽  
Author(s):  
Stefano Cianci ◽  
Martina Arcieri ◽  
Giuseppe Vizzielli ◽  
Canio Martinelli ◽  
Roberta Granese ◽  
...  

Pelvic exenteration represents the last resort procedure for patients with advanced primary or recurrent gynecological malignancy. Pelvic exenteration can be divided into different subgroup based on anatomical extension of the procedures. The growing application of the minimally invasive surgical approach unlocked new perspectives for gynecologic oncology surgery. Minimally invasive surgery may offer significant advantages in terms of perioperative outcomes. Since 2009, several Robotic Assisted Laparoscopic Pelvic Exenteration experiences have been described in literature. The advent of robotic surgery resulted in a new spur to the worldwide spread of minimally invasive pelvic exenteration. We present a review of the literature on robotic-assisted pelvic exenteration. The search was conducted using electronic databases from inception of each database through June 2021. 13 articles including 53 patients were included in this review. Anterior exenteration was pursued in 42 patients (79.2%), 2 patients underwent posterior exenteration (3.8%), while 9 patients (17%) were subjected to total exenteration. The most common urinary reconstruction was non-continent urinary diversion (90.2%). Among the 11 women who underwent to total or posterior exenteration, 8 (72.7%) received a terminal colostomy. Conversion to laparotomy was required in two cases due to intraoperative vascular injury. Complications' report was available for 51 patients. Fifteen Dindo Grade 2 complications occurred in 11 patients (21.6%), and 14 grade 3 complications were registered in 13 patients (25.5%). Only grade 4 complications were reported (2%). In 88% of women, the resection margins were negative. Pelvic exenteration represents a salvage procedure in patients with recurrent or persistent gynecological cancers often after radiotherapy. A careful patient selection remains the milestone of such a mutilating surgery. The introduction of the minimally invasive approach has led to advantages in terms of perioperative outcomes compared to classic open surgery. This review shows the feasibility of robotic pelvic exenteration. An important step forward should be to investigate the potential equivalence between robotic approaches and the laparotomic one, in terms of long-term oncological outcomes.


Author(s):  
Giovanni Concistrè ◽  
Antonio Miceli ◽  
Francesca Chiaramonti ◽  
Pierandrea Farneti ◽  
Stefano Bevilacqua ◽  
...  

Objective Aortic valve replacement in minimally invasive approach has shown to improve clinical outcomes even with a prolonged cardiopulmonary bypass and aortic cross-clamp (ACC) time. Sutureless aortic valve implantation may ideally shorten operative time. We describe our initial experience with the sutureless 3f Enable (Medtronic, Inc, ATS Medical, Minneapolis, MN USA) aortic bioprosthesis implanted in minimally invasive approach in high-risk patients. Methods Between May 2010 and May 2011, thirteen patients with severe aortic stenosis underwent aortic valve replacement with the 3f Enable bioprosthesis through an upper V-type ministernotomy interrupted at the second intercostal space. The mean ± SD age was 77 ± 3.9 years (range, 72–83 years), 10 patients were women, and the mean ± SD logistic EuroSCORE was 15% ± 13.5%. Echocardiography was performed preoperatively, at postoperative day 1, at discharge, and at follow-up. Clinical data, adverse events, and patient outcomes were recorded retrospectively. The median follow-up time was 4 months (interquartile range, 2–10 months). Results Most of the implanted valves were 21 mm in diameter (19–25 mm). The CPB and ACC times were 100.2 ± 25.3 and 66.4 ± 18.6 minutes. At short-term follow-up, the mean ± SD pressure gradient was 14 ± 4.9 mm Hg; one patient showed trivial paravalvular leakage. No patients died during hospital stay or at follow-up. Conclusions The 3f Enable sutureless bioprosthesis implanted in minimally invasive approach through an upper V-type ministernotomy is a feasible, safe, and reproducible procedure. Hemodynamic and clinical data are promising. This innovative approach might be considered as an alternative in high-risk patients. Reduction of CPB and ACC time is possible with increasing of experience and sutureless evolution of actual technology.


2018 ◽  
Vol 06 (01) ◽  
pp. e18-e22 ◽  
Author(s):  
Mariela Dore ◽  
Paloma Triana Junco ◽  
Carlos De La Torre ◽  
Alejandra Vilanova-Sánchez ◽  
Monserrat Bret ◽  
...  

Introduction Minimally invasive repair for pectus excavatum (MIRPE) is controversial in extremely severe cases of pectus excavatum (PE) and an open repair is usually favored. Our aim is to describe a case of a patient with an extremely severe PE that underwent a minimally invasive approach. Case report An 8-year-old girl with severe sternum depression was assessed. She had a history of exercise intolerance, nocturnal dyspnea, fatigue, and shortness of breath. Chest computed tomography showed that sternum depression was posterior to the anterior vertebral column; therefore, Haller and correction index could not be measured. Spirometry indicated an obstructive ventilation pattern (forced expiratory volume in 1 second = 74.4%), and echocardiogram revealed a dilated inferior vena cava, mitral valve prolapse with normal ventricular function. After multidisciplinary committee evaluation, a MIRPE approach was performed.All symptoms had disappeared at the 3-month postoperative follow-up; the desired sternum shape was achieved and normalization of cardiopulmonary function was observed. The Nuss bars were removed after a 2-year period. After 18-month follow-up, the patient can carry out normal exercise and is content with the cosmetic result. Conclusion Nuss procedure is feasible in our 8-year-old patient. In this case, both the Haller and correction index were not useful to assess the severity of PE. Therefore, under these circumstances, other radiologic parameters have to be taken into consideration for patient evaluation.


Sign in / Sign up

Export Citation Format

Share Document