High-frequency-stability diode-pumped Nd:YAG lasers with the FM sidebands method and Doppler-free iodine lines at 532 nm

1999 ◽  
Vol 38 (33) ◽  
pp. 6962 ◽  
Author(s):  
Gianluca Galzerano ◽  
Cesare Svelto ◽  
Elio Bava ◽  
Fabrizio Bertinetto
1996 ◽  
Vol 05 (03) ◽  
pp. 543-550
Author(s):  
VERED MAHAL ◽  
ADY ARIE

Two diode-pumped tunable Nd:YAG lasers locked to sub-Doppler transitions of 127I2 and 133 Cs 2 are used as a source for two-wavelength interferometry. The synthetic wavelength, Λ=c/∆ν, is highly stable and accurate, owing to the frequency stability of the locked lasers and the precise determination of the frequency difference Δν between Cs 2 and I 2 transitions. The dense spectra of these molecules allows selection of Λ over a wide range, between 8.5 mm and several meters, thus enabling distance measurements with a large non-ambiguity range. Fringe contrast and phase-shifting methods are used to measure the phase difference. An accuracy of 70 μm is achieved for Λ~19 mm, i.e. Λ/260.


2000 ◽  
Vol 36 (5) ◽  
pp. 480 ◽  
Author(s):  
S. Chang ◽  
A.G. Mann ◽  
A.N. Luiten

1990 ◽  
Author(s):  
Walter R. Leeb ◽  
Arpad L. Scholtz ◽  
Klaus Pribil

1995 ◽  
Author(s):  
Thomas J. Kane ◽  
David C. Gerstenberger ◽  
Joseph J. Alonis ◽  
Mike Tubb

2000 ◽  
Vol 25 (17) ◽  
pp. 1228 ◽  
Author(s):  
V. Wulfmeyer ◽  
M. Randall ◽  
A. Brewer ◽  
R. M. Hardesty

1995 ◽  
Author(s):  
Krzysztof Kopczynski ◽  
Roman Czechowicz
Keyword(s):  

2018 ◽  
Vol 83 (2) ◽  
pp. 213-220
Author(s):  
Sung Kim ◽  
Pankaj Attri ◽  
In Kim

In this paper, photosensitive materials for information storage devices are presented. The polymers were prepared using surface relief-grating (SRG) fabrication with a diode-pumped solid-state (DPSS) laser of 532 nm, and the diffraction efficiency (DE) of the polymers were assessed with a low-power DPSS laser at 633 nm. However, the diffraction efficiency of the azo-functionalized epoxy-based polymer was low, even after 15 min of exposure. To improve the efficiency and reduce the time it takes for the DE measurements of the photosensitive polymer, the polymer was combined ionic liquids (ILs). Various ILs, i.e., 1-methylimidazolium chloride ([Mim]Cl) from the imidazolium family of ILs and diethylammonium dihydrogen phosphate (DEAP), triethylammonium 4-aminotoluene-3-sulfonic acid (TASA) and tributylmethylammonium methyl sulphate (TBMS) from the ammonium family of ILs, were investigated. For the first time, it was observed that DE dramatically increased the DEAP?polymer mixture in 4 min compared to the polymer (alone) and other polymer?IL mixtures. Therefore, DEAP IL could help improve the efficiency of DE measurements in a shorter time.


2020 ◽  
Author(s):  
Samuel Francis

<p>In this talk, the current status of the LRI instrument will be presented. Topics will include laser frequency stability since launch, current best estimate of the noises in the LRI range spectra, and a look at some high-frequency signals visible in the LRI range measurement.</p>


Sign in / Sign up

Export Citation Format

Share Document