scholarly journals Ultra-Long Duration Time-Resolved Spectroscopy with Enhanced Temporal Resolution of High-Q Nano-Optomechanical Modes using Interleaved Asynchronous Optical Sampling (I-ASOPS)

CLEO: 2014 ◽  
2014 ◽  
Author(s):  
Aleem M. Siddiqui ◽  
Robert L. Jarecki ◽  
Andrew Starbuck ◽  
Jonathan A. Cox
2010 ◽  
Vol 59 (12) ◽  
pp. 3262-3269 ◽  
Author(s):  
Zachary J. Taylor ◽  
Roi Gurka ◽  
Gregory A. Kopp ◽  
Alex Liberzon

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
D. Bajek ◽  
M. A. Cataluna

AbstractWe demonstrate, for the first time, optical sampling by repetition-rate tuning (OSBERT) at record megahertz scan rates. A low-cost, tunable and extremely compact 2-section passively mode-locked laser diode (MLLD) is used as the pulsed laser source, whose repetition rate can be modulated electronically through biasing of the saturable absorber section. The pulsed output is split into two arms comparable to an imbalanced Michelson interferometer, where one arm is significantly longer than the other (a passive delay line, or PDL). The resulting electronic detuning of the repetition rate gives rise to a temporal delay between pulse pairs at a detector; the basis for time-resolved spectroscopy. Through impedance-matching, we developed a new system whereby a sinusoidal electrical bias could be applied to the absorber section of the MLLD via a signal generator, whose frequency could be instantly increased from sub-hertz through to megahertz modulation frequencies, corresponding to a ground-breaking megahertz optical sampling scan rate, which was experimentally demonstrated by the real-time acquisition of a cross-correlation trace of two ultrashort optical pulses within just 1 microsecond of real time. This represents scan rates which are three orders of magnitude greater than the recorded demonstrations of OSBERT to date, and paves the way for highly competitive scan rates across the field of time-resolved spectroscopy and applications therein which range from pump probe spectroscopy to metrology.


RSC Advances ◽  
2020 ◽  
Vol 10 (71) ◽  
pp. 43459-43471
Author(s):  
Hussain A. Z. Sabek ◽  
Ahmed M. M. Alazaly ◽  
Dina Salah ◽  
Hesham S. Abdel-Samad ◽  
Mohamed A. Ismail ◽  
...  

Solvation-dependent photophysical properties of two push–pull thiophene-based compounds with donor–π–acceptor (D–π–A) structures were investigated using absorption, fluorescence emission and time resolved spectroscopy, and supported by different solvation models.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Abhik Datta ◽  
Kian Fong Ng ◽  
Deepan Balakrishnan ◽  
Melissa Ding ◽  
See Wee Chee ◽  
...  

AbstractFast, direct electron detectors have significantly improved the spatio-temporal resolution of electron microscopy movies. Preserving both spatial and temporal resolution in extended observations, however, requires storing prohibitively large amounts of data. Here, we describe an efficient and flexible data reduction and compression scheme (ReCoDe) that retains both spatial and temporal resolution by preserving individual electron events. Running ReCoDe on a workstation we demonstrate on-the-fly reduction and compression of raw data streaming off a detector at 3 GB/s, for hours of uninterrupted data collection. The output was 100-fold smaller than the raw data and saved directly onto network-attached storage drives over a 10 GbE connection. We discuss calibration techniques that support electron detection and counting (e.g., estimate electron backscattering rates, false positive rates, and data compressibility), and novel data analysis methods enabled by ReCoDe (e.g., recalibration of data post acquisition, and accurate estimation of coincidence loss).


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
C. Callenberg ◽  
A. Lyons ◽  
D. den Brok ◽  
A. Fatima ◽  
A. Turpin ◽  
...  

AbstractImaging across both the full transverse spatial and temporal dimensions of a scene with high precision in all three coordinates is key to applications ranging from LIDAR to fluorescence lifetime imaging. However, compromises that sacrifice, for example, spatial resolution at the expense of temporal resolution are often required, in particular when the full 3-dimensional data cube is required in short acquisition times. We introduce a sensor fusion approach that combines data having low-spatial resolution but high temporal precision gathered with a single-photon-avalanche-diode (SPAD) array with data that has high spatial but no temporal resolution, such as that acquired with a standard CMOS camera. Our method, based on blurring the image on the SPAD array and computational sensor fusion, reconstructs time-resolved images at significantly higher spatial resolution than the SPAD input, upsampling numerical data by a factor $$12 \times 12$$ 12 × 12 , and demonstrating up to $$4 \times 4$$ 4 × 4 upsampling of experimental data. We demonstrate the technique for both LIDAR applications and FLIM of fluorescent cancer cells. This technique paves the way to high spatial resolution SPAD imaging or, equivalently, FLIM imaging with conventional microscopes at frame rates accelerated by more than an order of magnitude.


Sign in / Sign up

Export Citation Format

Share Document