Regularization, experimental errors, and accuracy estimation in tomography and interferometry

1987 ◽  
Vol 4 (11) ◽  
pp. 2033 ◽  
Author(s):  
E. A. Dubovikova ◽  
M. S. Dubovikov
2003 ◽  
Vol 775 ◽  
Author(s):  
Sung-Hwa Oh ◽  
Ju-Myung Song ◽  
Joon-Seop Kim ◽  
Hyang-Rim Oh ◽  
Jeong-A Yu

AbstractSolution behaviors of poly(styrene-co-sodium methacrylate) were studied by fluorescence spectroscopic methods using pyrene as a probe. The mol% of methacrylate was in the range 3.6–9.4. Water and N,N-dimethylforamide(DMF) mixture was used as a solvent (DMF/water = 0.2 mol %). The critical micelle (or aggregation) concentrations of ionomers and the partition coefficients of pyrene were obtained the temperature range 10–80°C. At room temperature, the values of CMCs (or CACs) were in the range 4.7 ×10-6 5.3 ×10-6 g/mL and we could not find any notable effect of the content of ionic repeat units within the experimental errors. Unlike CMCs, as the ion content increased, partitioning of pyrene between the hydrophobic aggregates and an aqueous media decreased from 1.5 ×105 to 9.4 ×104. As the temperature increased from 10 to 80 °C, the values of CMCs increased less than one order of magnitude. While, the partition coefficients of pyrene decreased one order of magnitude and the effect of the ion content became negligible.


1987 ◽  
Vol 52 (6) ◽  
pp. 1386-1396 ◽  
Author(s):  
Ján Mocák ◽  
Michal Németh ◽  
Mieczyslaw Lapkowski ◽  
Jerzy W. Strojek

A spectrocoulometric macrocell with a direct-view optical probe was designed and constructed, where the optical signal is transferred by light-conducting glass or quartz fibres permitting to work at wavelengths above 410 or 300 nm. The method of measurement on the proposed equipment is described; it was tested in the study of the mechanism and kinetics of oxidation of Fe(bipy)32+ ions (bipy = 2,2'-bipyridyl) with the use of potentiostatic coulometric electrolysis with open-circuit relaxation at a suitable time. The primary product of electrolysis, Fe(bipy)33+, undergoes a follow-up hydrolytic reaction with the formation of a binuclear complex. The rate constant of the reaction of the first order involves the contributions, kBi, from all bases present in solution; the corresponding values for H2O, OH-, bipy, and CH3COO- ions at a ionic strength 0·5 mol dm-3 and 25 °C were determined as kOH = (5·0 ± 0·6) . 105 mol-1 dm3 s-1, kbipy = (1·3 ± 0·2) . 10-1 mol-1 dm3 s-1, kAc = (5·8 ± 1·0) . 10-2 mol-1 dm3 s-1, and kH2O is not significant with respect to experimental errors.


2004 ◽  
Vol 69 (2) ◽  
pp. 419-425 ◽  
Author(s):  
Katarína Gmucová ◽  
Jozef Orlický ◽  
Juraj Pavlásek

The redox reaction of the neurotransmitter dopamine at the carbon fibre microelectrode was studied by several electrochemical methods. It was found that under conditions usual in a living body, the diffusion current fullfils, within experimental errors, the behavior theoretically predicted by the Cottrell equation. Nevertheless, attention should be paid to the fact that unsupported or weakly supported conditions give rise to a non-Cottrell response of diffusion current. Moreover, similar changes were observed if the dopamine concentration was either lower such as several units of μmol l-1, or about 100 μmol l-1 or higher. The non-Cottrell behavior of diffusion current involves the nonlinearity of the dopamine calibration curve obtained by pulse techniques. The present work is aimed at pointing out that such behavior of the measured data could lead to misinterpretation of the obtained dopamine concentration. Similar features could be also achieved for the other catecholamines.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ryoya Shiode ◽  
Mototaka Kabashima ◽  
Yuta Hiasa ◽  
Kunihiro Oka ◽  
Tsuyoshi Murase ◽  
...  

AbstractThe purpose of the study was to develop a deep learning network for estimating and constructing highly accurate 3D bone models directly from actual X-ray images and to verify its accuracy. The data used were 173 computed tomography (CT) images and 105 actual X-ray images of a healthy wrist joint. To compensate for the small size of the dataset, digitally reconstructed radiography (DRR) images generated from CT were used as training data instead of actual X-ray images. The DRR-like images were generated from actual X-ray images in the test and adapted to the network, and high-accuracy estimation of a 3D bone model from a small data set was possible. The 3D shape of the radius and ulna were estimated from actual X-ray images with accuracies of 1.05 ± 0.36 and 1.45 ± 0.41 mm, respectively.


A method for the measurement of permittivity at microwave frequencies using an open resonator is proposed. The theory of the method is developed, and an experimental procedure is evolved and justified. It is shown that the present method has advantages over other open resonator methods which have been proposed, and a thorough experimental study of the method has shown that experimental errors can be made very small indeed.


Sign in / Sign up

Export Citation Format

Share Document