scholarly journals Multi Source Translation Based Projection Completion for Interior Region of Interest Tomography with CBCT

2022 ◽  
Author(s):  
Tan Chuandong ◽  
Haijun Yu ◽  
yarui xi ◽  
Li Lei ◽  
mingjuan liao ◽  
...  
Author(s):  
Yixing Huang ◽  
Leonid Mill ◽  
Robert Stoll ◽  
Lasse Kling ◽  
Oliver Aust ◽  
...  

2011 ◽  
Vol 38 (3) ◽  
pp. 1307-1312 ◽  
Author(s):  
Katsuyuki Taguchi ◽  
Jingyan Xu ◽  
Somesh Srivastava ◽  
Benjamin M. W. Tsui ◽  
Jochen Cammin ◽  
...  

2008 ◽  
Vol 2008 ◽  
pp. 1-6 ◽  
Author(s):  
Yangbo Ye ◽  
Hengyong Yu ◽  
Ge Wang

Using filtered backprojection (FBP) and an analytic continuation approach, we prove that exact interior reconstruction is possible and unique from truncated limited-angle projection data, if we assume a prior knowledge on a subregion or subvolume within an object to be reconstructed. Our results show that (i) the interior region-of-interest (ROI) problem and interior volume-of-interest (VOI) problem can be exactly reconstructed from a limited-angle scan of the ROI/VOI and a 180 degree PI-scan of the subregion or subvolume and (ii) the whole object function can be exactly reconstructed from nontruncated projections from a limited-angle scan. These results improve the classical theory of Hamaker et al. (1980).


2016 ◽  
Vol 43 (6Part11) ◽  
pp. 3450-3450
Author(s):  
K Kim ◽  
D Kim ◽  
S Kang ◽  
T Kim ◽  
D Shin ◽  
...  

Author(s):  
R.J. Mount ◽  
R.V. Harrison

The sensory end organ of the ear, the organ of Corti, rests on a thin basilar membrane which lies between the bone of the central modiolus and the bony wall of the cochlea. In vivo, the organ of Corti is protected by the bony wall which totally surrounds it. In order to examine the sensory epithelium by scanning electron microscopy it is necessary to dissect away the protective bone and expose the region of interest (Fig. 1). This leaves the fragile organ of Corti susceptible to physical damage during subsequent handling. In our laboratory cochlear specimens, after dissection, are routinely prepared by the O-T- O-T-O technique, critical point dried and then lightly sputter coated with gold. This processing involves considerable specimen handling including several hours on a rotator during which the organ of Corti is at risk of being physically damaged. The following procedure uses low cost, readily available materials to hold the specimen during processing ,preventing physical damage while allowing an unhindered exchange of fluids.Following fixation, the cochlea is dehydrated to 70% ethanol then dissected under ethanol to prevent air drying. The holder is prepared by punching a hole in the flexible snap cap of a Wheaton vial with a paper hole punch. A small amount of two component epoxy putty is well mixed then pushed through the hole in the cap. The putty on the inner cap is formed into a “cup” to hold the specimen (Fig. 2), the putty on the outside is smoothed into a “button” to give good attachment even when the cap is flexed during handling (Fig. 3). The cap is submerged in the 70% ethanol, the bone at the base of the cochlea is seated into the cup and the sides of the cup squeezed with forceps to grip it (Fig.4). Several types of epoxy putty have been tried, most are either soluble in ethanol to some degree or do not set in ethanol. The only putty we find successful is “DUROtm MASTERMENDtm Epoxy Extra Strength Ribbon” (Loctite Corp., Cleveland, Ohio), this is a blue and yellow ribbon which is kneaded to form a green putty, it is available at many hardware stores.


2004 ◽  
Vol 43 (06) ◽  
pp. 185-189 ◽  
Author(s):  
J. T. Kuikka

Summary Aim: Serotonin transporter (SERT) imaging can be used to study the role of regional abnormalities of neurotransmitter release in various mental disorders and to study the mechanism of action of therapeutic drugs or drugs’ abuse. We examine the quantitative accuracy and reproducibility that can be achieved with high-resolution SPECT of serotonergic neurotransmission. Method: Binding potential (BP) of 123I labeled tracer specific for midbrain SERT was assessed in 20 healthy persons. The effects of scatter, attenuation, partial volume, mis-registration and statistical noise were estimated using phantom and human studies. Results: Without any correction, BP was underestimated by 73%. The partial volume error was the major component in this underestimation whereas the most critical error for the reproducibility was misplacement of region of interest (ROI). Conclusion: The proper ROI registration, the use of the multiple head gamma camera with transmission based scatter correction introduce more relevant results. However, due to the small dimensions of the midbrain SERT structures and poor spatial resolution of SPECT, the improvement without the partial volume correction is not great enough to restore the estimate of BP to that of the true one.


2001 ◽  
Vol 40 (04) ◽  
pp. 107-110 ◽  
Author(s):  
B. Roßmüller ◽  
S. Alalp ◽  
S. Fischer ◽  
S. Dresel ◽  
K. Hahn ◽  
...  

SummaryFor assessment of differential renal function (PF) by means of static renal scintigraphy with Tc-99m-dimer-captosuccinic acid (DMSA) the calculation of the geometric mean of counts from the anterior and posterior view is recommended. Aim of this retrospective study was to find out, if the anterior view is necessary to receive an accurate differential renal function by calculating the geometric mean compared to calculating PF using the counts of the posterior view only. Methods: 164 DMSA-scans of 151 children (86 f, 65 m) aged 16 d to 16 a (4.7 ± 3.9 a) were reviewed. The scans were performed using a dual head gamma camera (Picker Prism 2000 XP, low energy ultra high resolution collimator, matrix 256 x 256,300 kcts/view, Zoom: 1.6-2.0). Background corrected values from both kidneys anterior and posterior were obtained. Using region of interest technique PF was calculated using the counts of the dorsal view and compared with the calculated geometric mean [SQR(Ctsdors x Ctsventr]. Results: The differential function of the right kidney was significantly less when compared to the calculation of the geometric mean (p<0.01). The mean difference between the PFgeom and the PFdors was 1.5 ± 1.4%. A difference > 5% (5.0-9.5%) was obtained in only 6/164 scans (3.7%). Three of 6 patients presented with an underestimated PFdors due to dystopic kidneys on the left side in 2 patients and on the right side in one patient. The other 3 patients with a difference >5% did not show any renal abnormality. Conclusion: The calculation of the PF from the posterior view only will give an underestimated value of the right kidney compared to the calculation of the geometric mean. This effect is not relevant for the calculation of the differntial renal function in orthotopic kidneys, so that in these cases the anterior view is not necesssary. However, geometric mean calculation to obtain reliable values for differential renal function should be applied in cases with an obvious anatomical abnormality.