scholarly journals Correction: Influence of intraocular lens subsurface nanoglistenings on functional visual acuity

PLoS ONE ◽  
2017 ◽  
Vol 12 (4) ◽  
pp. e0176318
Author(s):  
PLoS ONE ◽  
2017 ◽  
Vol 12 (3) ◽  
pp. e0173574 ◽  
Author(s):  
Takahiro Hiraoka ◽  
Kazunori Miyata ◽  
Takeshi Hayashidera ◽  
Masaharu Iida ◽  
Keita Takada ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Tatsuya Jujo ◽  
Jiro Kogo ◽  
Hiroki Sasaki ◽  
Reio Sekine ◽  
Keiji Sato ◽  
...  

Abstract Backgrounds However there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar. Methods Nineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o’clock, 2 mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications. Results The 19 eyes were followed up for 1 month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.06 ± 0.63 and 0.40 ± 0.26, respectively (p < 0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27 ± 0.51 and 0.06 ± 0.15, respectively (p = 0.09). The mean corneal endothelial cell density was 2406 ± 625 to 2004 ± 759 cells/mm2 at 1 month (p = 0.13). The mean IOL tilt was 3.52 ± 3.00°, and the mean IOL decentration was 0.39 ± 0.39 mm. There was no correlation among IOL tilt, decentration and BCVA (p > 0.05). The mean prediction error of the target refraction was − 0.03 ± 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred. Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ahmed A. Zein El-Dein ◽  
Ahmed Elmassry ◽  
Hazem M. El-Hennawi ◽  
Ehab F. Mossallam

Abstract Background This study aimed to assess visual outcomes, quality of vision and patients’ satisfaction of a trifocal diffractive intraocular lens after cataract surgery with phacoemulsification. Results The study included 36 eyes that underwent implantation of trifocal diffractive intraocular lens (IOL). The residual mean postoperative spherical equivalent was − 0.40 ± 0.29 diopters. Mean Uncorrected distance visual acuity was 0.80 ± 0.16 decimal (snellen equivalent 25 ft) while mean Uncorrected intermediate visual acuity was 0.82 ± 0.31 decimal (snellen equivalent 25 ft) and mean Uncorrected near visual acuity (UCNVA) was 0.87 ± 0.20 decimal (snellen equivalent 23 ft). In defocus curve, there was infinitesimal gradual change between the three foci. Contrast sensitivity was just below the inferior limit of normal. Conclusion Trifocal diffractive IOL created a true intermediate focus proved by VA and defocus curve and better quality of vision assessed by contrast sensitivity and high order aberration. Moreover, it was safe and effective for correcting distance and near vision in these patients. Most of the patients were very satisfied and achieved spectacle independence. Trial registration Registration number and date: NCT04465279 on July 10, 2020.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Dilek Yaşa ◽  
Ufuk Ürdem ◽  
Alper Ağca ◽  
Yusuf Yildirim ◽  
Burçin Kepez Yildiz ◽  
...  

Purpose. To report clinical results of a foldable, hydrophilic acrylic, single-piece, injectable, posterior chamber phakic intraocular lens (pIOL).Material and Methods. Medical records of patients who underwent posterior chamber phakic IOL (Eyecryl Phakic IOL, Biotech Vision Care, Ahmedabad, India) implantation for surgical correction of myopia were retrospectively reviewed. Only patients with at least a one-year follow-up were included. Manifest refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), endothelial cell density (ECD), and pIOL vault were analyzed at 1, 3, 6, and 12 months after surgery. Complications observed during and after surgery were also recorded.Results. The study included 58 eyes of 29 patients. Mean patient age was 32 ± 7 years. Spherical equivalent of manifest refraction was −13.41 ± 3.23 D preoperatively and −0.44 ± 0.55 D postoperatively. Preoperative CDVA was 0.29 ± 0.71 logMAR. Postoperative UDVA and CDVA were 0.21 ± 0.66 and 0.15 ± 0.69 logMAR, respectively, at the 12-month visit. At the 12-month visit, the efficacy index was 1.20 and the safety index was 1.39. Mean ECD was 2713 ± 339 cells/mm2at the preoperative visit and 2608 ± 362 cells/mm2at the 12-month visit (3.9% loss,p<0.001). ECD loss from 3 months to 12 months was not statistically significant. No significant cataract formation, significant endothelial cell loss, glaucoma, uveitis, or any other vision-threatening complication was observed.Conclusion. Based on postoperative experience, we have found that Eyecryl Phakic IOL is safe and effective for treating high myopia.


2014 ◽  
Vol 6 (1) ◽  
pp. 102-104
Author(s):  
Mrindu Chaudhry ◽  
Keerti Mundey ◽  
Shikha Baisakhiya ◽  
Sumita Sethi

Objective: To report a rare case of intraocular lens (ACIOL) opacification in the anterior chamber in an adolescent and to discuss the possible mechanism of its occurrence and the ways of its prevention. Case: A 16-year-old male underwent cataract surgery for developmental cataract with placement of a foldable posterior chamber IOL in the anterior chamber. There was subsequent opacification of the IOL, which was replaced by a scleral fixated posterior chamber intraocular lens. The post-operative visual acuity improved to 6/18. Conclusion: The posterior chamber IOL implanted in the anterior chamber can get opacified possibly due to postoperative intraocular inflammation. DOI: http://dx.doi.org/10.3126/nepjoph.v6i1.10780   Nepal J Ophthalmol 2014; 6 (2): 102-104


2013 ◽  
Vol 13 (2) ◽  
pp. 33-41
Author(s):  
Devendra Maheshwari ◽  
Rengappa Ramakrishanan ◽  
Mohideen Abdul Kader ◽  
Neelam Pawar ◽  
Ankit Gupta

Aim: To evaluate the effect of phacoemulsification with intraocular lens implantation in eyes with pre-existing trabeculectomy.Methods: This prospective single-center clinical study evaluated intraocular pressure in 60 eyes of 60 patients who underwent phacoemulsification and implantation of a foldable intraocular lens after a previous successful trabeculectomy. Patients who had a trabeculectomy more than one year prior to the study were included. Intraocular pressure, number of antiglaucoma medications, bleb appearance, and visual acuity were recorded preoperatively, and at each follow-up examination and 12 months after phacoemulsification.Results: The mean intraocular pressure before phacoemulsification was 12.42 mmHg (SD, 4.60 mmHg), which increased to 14.98 mmHg (SD, 4.18 mmHg), 14.47 mmHg (SD, 3.58 mmHg), 15.44 mmHg (SD, 3.60 mmHg), and 15.71 mmHg (SD, 3.47 mmHg) after one, three, six, and 12 months, respectively. At each follow-up visit, the mean IOP was significantly higher than the preoperative value (p < 0.001, p = 0.015, p ≤ 0.001, and p = 0.001 at month one, three, six, and 12, respectively). The mean preoperative best-corrected visual acuity was 0.98 logMAR (SD, 0.44 logMAR) and the mean postoperative best-corrected visual acuity at 12 months was 0.20 logMAR (SD, 0.21 logMAR) [p = 0.0001]. The mean preoperative number of antiglaucoma medications used was 0.57 (SD, 0.63), which increased to 0.65 (SD, 0.63 ), 0.70 (SD, 0.72 ) 0.68, (SD, 0.70), and 0.67 (SD, 0.77 ) at one, three, six, and 12 months, respectively, but there were no statistically significant differences. Bleb size decreased clinically after phacoemulsification. Nineteen of 60 eyes (32%) developed fibrosis of bleb with decreased bleb size.Conclusion: Phacoemulsification with intraocular lens implantation significantly increased intraocular pressure and increased the number of antiglaucoma medications in eyes with pre-existing functioning filtering blebs.


2020 ◽  
Author(s):  
Da young Shin ◽  
Ho Sik Hwang ◽  
Hyun Seung Kim ◽  
Man Soo Kim ◽  
Eun Chul Kim

Abstract Background: To analyze and compare the clinical results of toric intraocular lens (IOL) and monofocal IOL implantation when the target refraction value is determined -3 diopter (D) in cataract patients with corneal astigmatism >1.5 diopters (D).Methods: We performed a retrospective chart review for patients with corneal astigmatism >1.5D who underwent cataract surgery and their target refraction is determined -3D. 100 eyes (100 patients; monofocal IOL, 60; toric IOL, 40) were enrolled in the current study. Near and distant uncorrected visual acuity (UCVA), corrected VA, spherical equivalent and refractive, corneal astigmatism were evaluated before and after surgery.Results: The near UCVA of the toric IOL group (0.26±0.33) after cataract surgery was significantly better than that of the monofocal IOL group (0.48±0.32) (p=0.030). The distant UCVA of the toric IOL group (0.38 ± 0.14) was also significantly better than that of the monofocal IOL group (0.55 ± 0.22) (p = 0.026). There were no significant intergroup differences in postoperative best-corrected visual acuity (p = 0.710) and mean spherical equivalent (p = 0.465). In the toric IOL group, postoperative refractive astigmatism was -0.80 ± 0.46D and postoperative corneal astigmatism was -1.50 ± 0.62D, whereas the corresponding values in the monofocal IOL group were -1.65 ± 0.77D and -1.45 ± 0.64D; residual refractive astigmatism was significantly lower with toric IOL implantation compared with monofocal IOL implantation (p = 0.001). Conclusions: When myopic refraction such as -3D was determined as the target power in patients with corneal astigmatism, toric IOL implantation led to excellent improvement in both near and distant UCVA.


2020 ◽  
pp. 173-176
Author(s):  
Kinjal Rathod ◽  
Kinjal Trivedi ◽  
Snehal Nayi ◽  
Somesh Aggarwal

Introduction: Cataract is most common cause of curable blindness worldwide and cataract surgery is most common procedure performed in ophthalmology. Posterior capsular opacification (PCO) is most common complication after cataract surgery which is usually treated with Neodymium-doped: Yttrium Garnet (Nd:YAG) laser posterior capsulotomy or occasionally with a surgical capsulotomy. The incidence and severity of PCO correlates to the type of surgical technique, IOL optic edge designs and IOL materials. Material and Methods: 70 eyes of 64 patients operated for age related cataract were studied in this prospective interventional study. Phacoemulsification was done in 35 eyes and SICS in 35 eyes with hydrophobic single piece biconvex foldable intraocular lens. Patients were followed up at 1, 3, 6, 9 and 12 months for the development of PCO. Clinically significant PCO (loss of 2 or more lines of Snellen’s visual acuity chart) was treated with Nd:YAG laser capsulotomy. Results: The overall incidence of PCO was 22.85%. Amongst the patients who developed PCO, SICS and phacoemulsification was performed in 62.5% and 37.5% patients respectively. Result was statistically significant with p value <0.05 using z test. On first postoperative day, patients operated with phacoemulsification had better visual acuity than SICS. Conclusion: Phacoemulsification can provide early and better visual outcome than SICS and has lower incidence of PCO formation which may be due to difference in irrigation and aspiration and less disruption of blood aqueous barrier than SICS. PCO can be reduced by atraumatic surgery and thorough cortical clean up and capsular polishing.


Sign in / Sign up

Export Citation Format

Share Document