scholarly journals Impact of the sinus node recovery time after termination of atrial fibrillation during catheter ablation on clinical outcomes in patients with persistent atrial fibrillation

PLoS ONE ◽  
2021 ◽  
Vol 16 (11) ◽  
pp. e0259750
Author(s):  
Keita Watanabe ◽  
Yasutoshi Nagata ◽  
Giichi Nitta ◽  
Shinichiro Okata ◽  
Masashi Nagase ◽  
...  

Background Although long sinus arrest is occasionally observed during atrial fibrillation (AF) catheter ablation when the fibrillation was terminated, its meaning and prognosis have not yet been clearly elucidated. We hypothesized that sinus node recovery time (SNRT) after termination of AF (time from termination of AF to the earliest sinus node activation) could reflect the extent of atrial remodeling, influencing the formation of non-pulmonary vein (non-PV) triggers and post-ablation outcomes. Method The participants were 157 consecutive patients with persistent AF (male: 77.1%, age: 63.3±11.2 years) who underwent catheter ablation. We recorded SNRT after terminating AF by radiofrequency delivery or electrical cardioversion during the first ablation and evaluated the relationships between SNRT and atrial tachyarrhythmia recurrence and between SNRT and non-PV triggers after repeat ablation. Results Forty-five patients (28.7%) experienced recurrence of atrial tachyarrhythmias. Patients with recurrence had longer SNRTs (1738 ms vs. 1394 ms, p = 0.012). In the multivariate logistic regression analysis, only SNRT ≥2128ms was a significant independent predictor of clinical AF recurrence (hazard ratio 7.48; 95% confidence interval 2.94–19.00; P<0.001). Kaplan–Meier estimator showed that the recurrence-free rate was significantly lower if ≥ 2128ms (log-rank, p<0.001). Thirty-five patients (77.8%) underwent a second ablation. Although there was no difference in the rate of pulmonary vein reconnections (78.6% vs. 71.4%, p = 0.712), non-PV triggers were observed more frequently in the longer SNRT group (57.1% vs. 14.3%, p = 0.012). Conclusions Patients with a prolonged SNRT had a higher prevalence of AF recurrence after the first ablation and higher inducibility of non-PV triggers. Measuring SNRT might be used for the stratification of patients with persistent AF.

2021 ◽  
Vol 49 (5) ◽  
pp. 030006052110101
Author(s):  
Zhi-Song Chen ◽  
Hong-Wei Tan ◽  
Hao-Ming Song ◽  
Wen-Jun Xu ◽  
Xue-Bo Liu

Objective Atrial fibrillation (AF) and sinus node dysfunction (SND) have common underlying pathophysiological mechanisms. As an index of SND, corrected sinus node recovery time (CSNRT) may also reflect atrial function. The aim of the present study was to determine whether CSNRT predicts AF recurrence in patients undergoing AF ablation. Methods Consecutive patients with paroxysmal atrial fibrillation (PAF) who underwent radiofrequency catheter ablation between January 2017 and December 2018 were enrolled. Clinical data, CSNRT, and other electrophysiology indices were collected and analysed between patients with or without AF recurrence. Results A total of 159 patients with PAF who underwent the same radiofrequency catheter ablation procedure were enrolled, including 25 patients with SND. During the one-year follow-up period, 22 patients experienced AF recurrence. Patients with recurrence had a significantly longer CSNRT and a larger left atrial volume index (LAVI) than patients without AF recurrence. SND (CSNRT > 550 ms) and a larger LAVI were independently associated with AF recurrence after ablation. A statistically significant CSNRT cut-off value of 550 ms predicted AF recurrence with 73% sensitivity and 85% specificity. Conclusion CSNRT and LAVI are independent predictors of PAF recurrence following ablation.


2018 ◽  
Vol 59 (3) ◽  
pp. 497-502 ◽  
Author(s):  
Naoko Yamaguchi ◽  
Yasuo Okumura ◽  
Ichiro Watanabe ◽  
Koichi Nagashima ◽  
Keiko Takahashi ◽  
...  

2019 ◽  
Vol 29 (5) ◽  
pp. 643-648 ◽  
Author(s):  
Jindong Chen ◽  
Hao Wang ◽  
Mengmeng Zhou ◽  
Liang Zhao

AbstractBackground:To assess the effectiveness of radiofrequency catheter ablation for lone atrial fibrillation in young adults.Methods:This single-centre, retrospective, observational study enrolled 75 consecutive patients (86.7% men) under 35 (median, 30) years old with lone atrial fibrillation (68% paroxysmal, 26.7% persistent, and 5.3% long-standing persistent) without other cardiopulmonary diseases who underwent catheter ablation between April 2009 and May 2017. Procedural endpoints were circumferential pulmonary vein ablation for atrial fibrillation with pulmonary vein trigger, and target ablation or bidirectional block of lines and disappearance of complex fractionated atrial electrograms for atrial fibrillation with clear and unclear non-pulmonary vein triggers, respectively.Results:Main study outcome was rate of survival free from atrial tachyarrhythmia recurrence, which at median 61 (range, 5–102) months follow-up was 62.7% (64.7 and 58.3% for paroxysmal and non-paroxysmal atrial fibrillation, respectively) after single ablation, and 69.3% (68.6 and 70.8% for paroxysmal and non-paroxysmal atrial fibrillation, respectively) after mean 1.2 ablations (two and three ablations in 11 and 2 patients, respectively). In multivariate analysis, non-pulmonary vein trigger was a significant independent predictor of recurrent atrial tachyarrhythmia (OR, 10.60 [95%CI, 2.25–49.96]; p = 0.003). There were no major periprocedural adverse events.Conclusions:In patients under 35 years old with lone atrial fibrillation, radiofrequency catheter ablation appeared effective particularly for atrial fibrillation with pulmonary vein trigger and regardless of left atrial size or atrial fibrillation duration or type. Atrial tachyarrhythmia recurrence after multiple ablations warrants further study.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Ying Wei ◽  
Shuwang Liu ◽  
Haiyi Yu ◽  
Yuan Zhang ◽  
Wei Gao ◽  
...  

The mechanisms underlying the recurrence of atrial fibrillation (AF) after radiofrequency catheter ablation (RFCA) are not well concerned. The study sought to explore the association between growth differentiation factor-15 (GDF-15) and the incidence of recurrent events among AF patients after the ablation procedure. We prospectively included 150 consecutive AF patients who underwent RFCA. Clinical information about the patients was collected. Blood samples on the second morning of hospital admission and three months after RFCA were collected, and enzyme-linked immunosorbent assay (ELISA) was used to measure the concentration of GDF-15. All participants were followed up at specific times (1st/3rd/6th/12th/18th/24th months) after RFCA to record recurrences events. During a median follow-up of 14.0 months, AF recurrence occurred in 37(24.7%) patients. Baseline serum GDF-15 level in the persistent AF group was significantly higher than the paroxysmal AF group [1140(854~1701)ng/L vs. 1062(651~1374)ng/L, P=0.039]. Baseline serum GDF-15 level in the recurrence group was significantly higher than the nonrecurrence group [1287(889~1768) ng/L vs. 1062(694~1373)ng/L, P=0.022]. Serum GDF-15 level at three months after RFCA was significantly lower than the baseline [870 (579~1270) ng/L vs. 1155 (735~1632)ng/L, P<0.001]. The baseline GDF-15 correlated significantly with LAP (r=0.296, P<0.001) and LAAV(r=−0.235, P=0.003). Kaplan-Meier analysis showed a significantly lower event-free survival time in the high baseline GDF-15 (≥1287.3 ng/L) group than the low baseline GDF-15 (<1287.3 ng/L) group (17.1 months vs. 20.4 months, Log Rank P=0.017). In the multivariate Cox regression, baseline GDF-15(HR 1.053, 95% CI 1.007-1.100, P=0.022) and LAD (HR 1.124, 95% CI 1.011-1.250, P=0.030) were independent predictors of AF recurrence after RFCA. Our study indicated increased preprocedural GDF-15 is associated with left atrial remodeling and acts as a predictor of AF recurrence after ablation.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
kiyotake Ishikawa ◽  
Yukihiko Yoshida ◽  
Sumio Morita ◽  
Kenji Furusawa ◽  
Noriyoshi Kanemura ◽  
...  

Background: Left atrium (LA) dilation plays an important role in development and persistence of atrial fibrillation (AF). Some cases show structural reverse remodeling of LA after catheter ablation of AF. The aim of this study was to assess the clinical significance of LA reverse remodeling. Method and Results: Echocardiographic data before and after ablation was obtained in 173 cases who underwent pulmonary vein isolation from January 2006 to April 2008 (74.0% men, 61.0±11 years old; paroxysmal AF 114, persistent AF 34, permanent AF 25). Mean atrial diameter before ablation was 39.0±6.1mm (paroxysmal 37.7±5.6mm, persistent 40.7±5.3mm, and permanent 43.0±6.8mm) and LA reverse remodeling was defined as 10% decrement of LA transverse diameter. Half of the cases were taking anti-arrhythmic drugs after ablation, and AF recurrence occurred in 16.8% (29/173) during mean follow up period of 8.5±6.3 months. Reverse remodeling of LA was seen in 34.1% (59/173) and AF recurrence rate in this group was 11.9% (7/59), whereas 19.3% (22/114) without reverse remodeling (P=0.29). However, limited in patients with LA diameter over 40mm (44.5%; 77/173), 3.2% (1/31) of AF recurrence was seen in those with reverse remodeling, while 21.7% (10/46) without reverse remodeling (P=0.04). LA reverse remodeling was observed significantly frequent in patients without history of hypertension(41.5% without hypertension vs 25.6% with hypertension, P=0.036). Conclusion: LA reverse remodeling after catheter ablation of AF in dilated LA patient is a simple and useful predictor for non-recurrence of AF. Hypertension could be a disturbance for LA reverse remodeling.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Laurent Macle ◽  
Atul Verma ◽  
Paul Novak ◽  
Paul Khairy ◽  
Mario Talajic ◽  
...  

Recurrences of atrial fibrillation (AF) after catheter ablation are frequently associated with recovery of conduction between the pulmonary veins (PV) and the atrium. The recovery of PV conduction could be explained by the presence of dormant conduction between the PV and the atrium. Adenosine can be used during AF ablation procedures to reveal transient re-conduction of the isolated pulmonary vein (dormant PV conduction). We prospectively evaluate the utility of iv adenosine to guide elimination of dormant PV conduction by additional radiofrequency (RF) applications during AF ablation procedures. Thirty-four consecutive patients (30 male; age 51+/−8 years) referred for catheter ablation of drug-refractory AF (Paroxysmal 31/Persistent 3) were studied. Electrical PV isolation (PVI) was performed using Irrigated-tip radiofrequency (RF) ablation and was guided by a circular mapping catheter. After PVI, the presence of dormant conduction in each vein was assessed by injection of 12 mg of adenosine. If dormant conduction was present, additional RF energy was delivered at sites of transient re-conduction. Abolition of the dormant conduction was then demonstrated by repeated injections of adenosine. The recurrence rate of arrhythmia after one procedure was evaluated. The results were compared to an historical control group comprising the previous 34 consecutive patients who underwent PVI without the use of adenosine. Electrical PVI was achieved in 100% of PV’s and all 34 patients underwent the adenosine evaluation. Dormant PV conduction was observed in 17/34 patients and could be eliminated in all by additional RF delivery. Procedural and fluoroscopy times were 163±30 and 49±13 minutes, respectively. After a mean follow-up of 8.0±3.1 months, 6/34 (18%) patients experienced AF recurrence with 28/34 (82%) remaining free of arrhythmia without the use of antiarrhythmic drugs. When compared to the 14/34 patients (41%) from the historical control group who had AF recurrence, a significant reduction was observed (P<0.01). The use of adenosine to guide elimination of dormant PV conduction increases the success rate of AF ablation procedures. This needs to be evaluated in a randomized multicenter trial.


Author(s):  
Samuel K. Sørensen ◽  
Arne Johannessen ◽  
René Worck ◽  
Morten L. Hansen ◽  
Jim Hansen

Background - Recurrent paroxysmal atrial fibrillation (PAF) after catheter ablation is presumably caused by failure to achieve durable pulmonary vein isolation (PVI). The primary methods of PVI are radiofrequency (RF) and cryoballoon (CRYO) catheter ablation, but these methods have not been directly compared with respect to PVI durability and the effect thereof on AF burden (% of time in AF). Methods - Accordingly, we performed a randomized trial including 98 patients (68% male, 61 [55-67] years) with PAF assigned 1:1 to PVI by contact-force sensing, irrigated RF catheter or second-generation CRYO catheter. Implantable cardiac monitors were inserted ≥1 month before PVI for assessment of AF burden and recurrence, and all patients, irrespective of AF recurrence, underwent a second procedure 4-6 months after PVI to determine PVI durability. Results - In the second procedure, 152/199 (76%) pulmonary veins (PVs) were found durably isolated after RF and 161/200 (81%) after CRYO (NS), corresponding to durable isolation of all veins in 47% of patients in both groups (NS). Median AF burden before PVI was 5.4% (interquartile range: 0.5-13.0%) vs. 4.0% (0.6-18.1%), RF vs. CRYO, and reduced to 0.0% (0.0-0.1%) and 0.0% (0.0-0.5%), respectively - a reduction of 99.9% (92.9-100.0%) and 99.3% (85.9-100.0%) (all NS). AF burden after PVI significantly correlated to the number of durably isolated PVs (p < 0.01), but 9/45 (20%) patients with durable isolation of all veins had recurrence of AF within 4-6 months after PVI (excluding a 3-month blanking period). Conclusions - PVI by RF and CRYO catheter ablation produce similar moderate to high PVI durability. Both treatments lead to marked reductions in AF burden, which is related to the number of durably isolated PVs. However, for one fifth of PAF patients, complete and durable PVI was not sufficient to prevent even short-term AF recurrence.


Sign in / Sign up

Export Citation Format

Share Document