scholarly journals A Comparative Study of Corneal Endothelial Cell Count and Central Corneal Thickness in Emmetropia and Axial Myopia

2020 ◽  
Vol 9 (44) ◽  
pp. 3300-3304
Author(s):  
Vandana Panjwani ◽  
Sachin Daigavane

BACKGROUND The main attributes of cornea which makes it optically important is its ability to maintain its dehydrated state. This corneal dehydration can be achieved and maintained by various factors among which corneal endothelial cell count and morphology play a significant role. Corneal attributes considered in this study i.e. the corneal endothelial cell count and central corneal thickness are extremely variable, and changes are seen even with smaller changes in anterior segment or overall structural changes in eyes. We wanted to compare central corneal thickness in emmetropia and axial myopia and compare corneal endothelial cell count in emmetropia and axial myopia. METHODS The sample size was decided taking into consideration various prevalence studies. The patients were consecutively recruited for the study considering the inclusion and exclusion criteria. The subjects were divided into two groups emmetropia and axial myopia and were differentiated on the basis of the axial lengths. Specular microscopy was performed for the subjects and corneal endothelial cell count, morphology and central corneal thickness were measured, and comparative study was performed. RESULTS This study of 80 eyes shows us that the difference between mean the corneal endothelial cell count between emmetrope (2812.80 cells / mm2) and axial myopes (2653 cells / mm2) is statistically significant where p was < 0.05 while the mean central corneal thickness measurements didn’t show statistically significant change between emmetrope (490.05 microns) and axial myope. (489.37 microns). CONCLUSIONS Axial length has an indirect correlation with the corneal endothelial cell count which is statistically significant. While significant correlation between the central corneal thickness and axial length cannot be established in this study. KEY WORDS Emmetropia, Axial Myopia, Corneal Endothelial Cell Count, Central Corneal Thickness, Comparison

2020 ◽  
Vol 36 (1) ◽  
Author(s):  
Syed Abdullar Mazhar ◽  
Sehar Zahid ◽  
Junaid Hanif ◽  
Muhammad Asharib Arshad ◽  
Rana Naveed Iqbal

Purpose:  To assess the mean corneal endothelial cell loss after Phacoemulsification in patients of type 2 diabetes. Study Design:  Cross-sectional study. Place and Duration of Study:  Layton Rahmatullah Benevolent Trust Free Eye and Cancer Hospital for a period of six months, from May 2015 to November 2015. Material and Methods:  Three hundred and fifty-five patients were selected by non-probability convenience sampling. Patients with cataract, diagnosed at least after 6 months of diagnosis of type 2 diabetes were included in this study. Patients with any systemic disease or ocular disease other than senile cataract were excluded from the study. Endothelial cell count was measured with Specular microscopy one day before surgery. One experienced surgeon with post-graduate experience of at least five years performed all the procedures. Follow up by specular microscopy was done at 6 weeks after phacoemulsification. Statistical analysis was done using SPSS version 23. Results:  Mean age of the patients was 59.32 ± 7.60 years. There were 41.97% males and 58.03% females. Mean endothelial cell count before phacoemulsification was 2177.21 ± 591.078 and 6 weeks after surgery was 1984 ± 597.51. Age, gender, laterality, duration of diabetes and type of cataract was not significantly related with endothelial cell loss, p-value > 0.05. Mean endothelial cells loss was higher in patients with HbA1c > 7 as compared to those with HbA1c < 7 (p-value = 0.01). Conclusion:  Patients with poor control of diabetes have higher endothelial cell loss after phacoemulsification than patients with good control.


2017 ◽  
Vol 19 (3) ◽  
pp. 1-8
Author(s):  
Syed Kubravi ◽  
Syed Qureshi ◽  
Shah Nawaz ◽  
Arshi Nazir ◽  
Khalid Kawoosa

Sign in / Sign up

Export Citation Format

Share Document