Shear Strength of Joints in Precast Concrete Segmental Bridges

2005 ◽  
Vol 102 (1) ◽  
Materials ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 2914 ◽  
Author(s):  
Haibo Jiang ◽  
Mingzhu Chen ◽  
Zhijun Sha ◽  
Jie Xiao ◽  
Jiahui Feng

Fixing imperfections in keyed dry joints between the concrete segments compromise the performance of precast concrete segmental bridges (PCSBs), which needs to consider carefully. In this study, a finite-element model on high-strength concrete single-keyed dry joints in PCSBs was established and validated by experimental results. Parametric studies on fixing imperfections in key, concrete strengths, and confining pressures were carried out based on that model. The numeric results included crack patterns, load–displacements and shear strength. Fixing imperfections—especially at lower surface of keys—reduced shear strength of single-keyed dry joints by the different shear transfer mechanism. Higher confining pressure and concrete strength improved the shear strength, but they mitigated and aggravated the effect of fixing imperfections at lower surface of key on shear strength, respectively. Compared with simulating results, AASHTO standard overestimated the shear capacity of single-keyed dry joints with fixing imperfections at lower surface of key by up to 0.602–22.0%, but greatly underestimated that of the rest. A modified formula with a strength reduction factor was proposed. For six experimental three-keyed dry-joint specimens and 30 numeric single-keyed dry-joint specimens with or without fixing imperfections, the average ratio of code predictions to experimental results was 90.4% and 81.6%, respectively.


2019 ◽  
Vol 20 (3) ◽  
pp. 955-970 ◽  
Author(s):  
Haibo Jiang ◽  
Jiahui Feng ◽  
Airong Liu ◽  
Weibin Liang ◽  
Yuhua Tan ◽  
...  

2021 ◽  
Vol 11 (2) ◽  
pp. 506
Author(s):  
Sun-Jin Han ◽  
Inwook Heo ◽  
Jae-Hyun Kim ◽  
Kang Su Kim ◽  
Young-Hun Oh

In this study, experiments and numerical analyses were carried out to examine the flexural and shear performance of a double composite wall (DCW) manufactured using a precast concrete (PC) method. One flexural specimen and three shear specimens were fabricated, and the effect of the bolts used for the assembly of the PC panels on the shear strength of the DCW was investigated. The failure mode, flexural and shear behavior, and composite behavior of the PC panel and cast-in-place (CIP) concrete were analyzed in detail, and the behavioral characteristics of the DCW were clearly identified by comparing the results of tests with those obtained from a non-linear flexural analysis and finite element analysis. Based on the test and analysis results, this study proposed a practical equation for reasonably estimating the shear strength of a DCW section composed of PC, CIP concrete, and bolts utilizing the current code equations.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Xinlei Yang ◽  
Hanchen Wu ◽  
Jianxin Zhang ◽  
Hailiang Wang

In order to improve the shear behavior of hollow concrete block masonry, precast concrete anti-shear blocks were proposed to enhance the shear strength of hollow concrete block masonry. Four groups of hollow concrete block masonry triplets with precast concrete anti-shear blocks were tested under shear loading, and their behaviors were compared with a control group. The results show that as the height of precast concrete anti-shear blocks increases, the shear strength of the masonry increases. The maximum shear strength of masonry triplets with precast concrete anti-shear blocks was 234.48 percent higher than that of the control specimens. The shear strength of masonry triplets was mainly determined by the failure of hollow concrete block unit. The majority of specimens exhibited double shear failures; however, these failures showed characteristics of ductile failure to a certain extent. Based on the experimental results, a equation for calculating the shear strength of masonry with precast concrete anti-shear blocks was proposed.


Sign in / Sign up

Export Citation Format

Share Document