DEVELOPMENT OF NUT-FREE ROLLER DRIVE POWER CALCULATION METHOD

Author(s):  
D. S. Blinov ◽  
M. I. Morozov
2018 ◽  
Vol 189 ◽  
pp. 02003 ◽  
Author(s):  
Heng Wu ◽  
Shufan Zhao ◽  
Jijun Zhang ◽  
Bo Sun ◽  
Hanqiang Song

Gas turbine power of turboshaft engine cannot be measured, a total of five typical steady state point test data from the ground slow state to the maximum state were selected according to the factory acceptance test drive of a certain type of carrier-based helicopter turboshaft engine. Combustion chamber three-dimensional simulation model was established to carry on simulation analysis of different typical steady state combustion process. The simulated combustion chamber exit section parameters are input into the established gas turbine isentropic adiabatic aerodynamic calculation model to obtain the gas turbine power and outlet temperature. Select five typical steady state points of five sets of turboshaft engines on the same type to repeat the above calculation process, and compare the calculated value of gas turbine outlet temperature with the acceptance test values, it is found that the error values are all within 5%, and the effectiveness and accuracy of the gas turbine power calculation method are verified.


2018 ◽  
Vol 9 (2) ◽  
pp. 264-268
Author(s):  
Tao Ming Thomas Chia ◽  
Hoon C. Jung

We report a case of patient dissatisfaction after sequential myopic and hyperopic LASIK in the same eye. We discuss the course of management for this patient involving eventual cataract extraction and intraocular lens (IOL) implantation with attention to the IOL power calculation method used.


Author(s):  
Asma Ezzaidi ◽  
Mustapha Elyaqouti ◽  
Lahoussine Bouhouch ◽  
Ahmed Ihlal

This paper is concerned with the assessment of the the performance of the Amougdoul wind farm. We have determined the Weibull parameters; namely the scale parameter, <em>c</em> (m/s) and shape parameter, <em>k</em>. After that, we have estimated energy output by a wind turbine using two techniques: the useful power calculation method and the method based on the modeling of the power curve, which is respectively 134.5 kW and 194.19 KW corresponding to 27% and 39% of the available wind energy, which confirm that the conversion efficiency does not exceed 40%.


2018 ◽  
Vol 28 (5) ◽  
pp. 559-565 ◽  
Author(s):  
Jorge A Calvo-Sanz ◽  
Javier Ruiz-Alcocer ◽  
Miguel A Sánchez-Tena

Purpose: To compare and analyze the accuracy of the refractive outcomes obtained in intraocular lens power calculation using the classical calculation method with mean keratometry (K) and the calculation method with both K meridians presented in this article. Methods: A total of 62 eyes of 62 subjects who were undergoing cataract surgery were included in this study. Optical biometry was performed using mean K and Haigis formula for classical intraocular lens calculation methods to achieve intraocular lens power; 4 weeks after surgery, prior to medical discharge, subjective refraction was made. Alternatively, intraocular lens power was calculated with bicylindric method using both keratometry readings, obtaining spherocylindrical refractive expected outcomes. Finally, results obtained with intraocular lens calculation methods, bicylindric method, and Haigis formula were compared. Results: Spherical equivalent calculated by classical intraocular lens calculation methods using Haigis formula (H-SE) was −0.027 ± 0.115 D and using bicylindric method (B-SE) was −0.080 ± 0.222 D. Achieved spherical equivalent obtained 4 weeks after surgery (A-SE) was −0.144 ± 0.268 D. Difference between H-SE and A-SE was −0.117 D (p = 0.002). Difference between B-SE and A-SE was not significant (−0.054 D, p = 0.109). Analysis in refraction groups showed a positive correlation between A-SE confronted to B-SE and H-SE (r = 0.313; p = 0.013 and r = 0.562; p < 0.001, respectively). This indicated a reliability in ametropic group prediction of 0.767 in H-SE and 0.843 in B-SE. Conclusion: Intraocular lens calculation with bicylindric method could be more accurate and had more reliability than classical intraocular lens calculation method. Bicylindric method adds astigmatism control and provides a reliable expected spherocylindrical refraction.


Sign in / Sign up

Export Citation Format

Share Document