scholarly journals Trunnionosis and metal wear causing metal hypersensitivity: 2 sides of the same coin?

2021 ◽  
Vol 64 (5) ◽  
pp. E534-E536
Author(s):  
Jans van der Merwe
2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Tim W. Rattay ◽  
Torsten Kluba ◽  
Ludger Schöls

AbstractA 53-year old male with a history of progressive visual impairment, hearing loss, peripheral neuropathy, poorly controlled diabetes mellitus, cardiomyopathy, and weight loss was referred to the rare disease center due to the suspicion of mitochondrial cytopathy. In line with mitochondrial dysfunction, lactate in CSF was increased. Genetic testing by whole-exome sequencing and mitochondrial DNA did not reveal a likely cause. The case remained unsolved until he developed pain in his right hip, where he had received total hip arthroplasty 12 years earlier. An orthopedic evaluation revealed substantial shrinkage of the head of the hip prosthesis. Due to metal-on-metal wear, debris chromium and cobalt levels in serum were massively increased and significantly improved with multisystemic impairment after exchanging the defective implant.


Coatings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 146
Author(s):  
Antonio Celentano ◽  
Tami Yap ◽  
Giuseppe Pantaleo ◽  
Rita Paolini ◽  
Michael McCullough ◽  
...  

Rigenera® is a novel class-1 medical device that produces micro-grafts enriched of progenitors cells without ex vivo manipulation of donor tissues. The manufacturer’s protocol has been supported for a wide variety of clinical uses in the field of regenerative medicine. This study aimed to evaluate its potential use for in vitro cell models. Human primary oral fibroblasts were cultured under standard conditions and processed through Rigenera® over a time course of up to 5 min. Cell viability was assessed using a Trypan Blue exclusion test. It is possible to process fibroblasts through Rigenera® although an initial reduction of cell viability was observed. Additionally, debris was evident in the cell suspension of the processed samples. Scanning electron microscopy (SEM) microanalysis of the debris and electron energy-loss spectroscopy confirmed the presence of metal wear possibly due to the processing conditions used in this study. Interestingly, pore sizes within Rigeneracons® grids were found to range between 250–400 μm. This is the first report assessing the suitability of Rigenera® and Rigeneracons® for in vitro applications. Whilst Rigenera® workflow was found to be amenable to laboratory uses, our results strongly suggest that further research and development is necessary to support the utilization of this technology for enrichment of micro-graft derived cells and cell sorting in vitro.


2017 ◽  
Vol 139 (2) ◽  
pp. AB243
Author(s):  
Sonam Sani ◽  
Luz S. Fonacier ◽  
Mark A. Davis-Lorton ◽  
Marcella Aquino

2018 ◽  
Vol 50 (3) ◽  
pp. 1162-1174 ◽  
Author(s):  
Jie Wan ◽  
Jingjing Qing ◽  
Mingzhi Xu
Keyword(s):  

2016 ◽  
Vol 117 (5) ◽  
pp. S45-S46
Author(s):  
S. Sani ◽  
L. Fonacier ◽  
M. Davis-Lorton ◽  
M. Aquino

2018 ◽  
Vol 141 (2) ◽  
pp. AB138
Author(s):  
Charmi Patel ◽  
Laura Helfner ◽  
Sherry Farzan ◽  
Artemio M. Jongco ◽  
Blanka M. Kaplan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document