Pb-210 irradiation dose estimation for inhabitants living in high natural background areas on Pernambuco/Brazil

2013 ◽  
Vol 9 (1) ◽  
pp. 12 ◽  
Author(s):  
C.E.O. Costa Júnior ◽  
E.B. Silva ◽  
A. Amaral ◽  
C.M. Silva ◽  
J.A. Santos Júnior
2018 ◽  
Vol 108 ◽  
pp. 20-25 ◽  
Author(s):  
R. Theinert ◽  
K. Kröninger ◽  
A. Lütfring ◽  
S. Mender ◽  
F. Mentzel ◽  
...  

2020 ◽  
Author(s):  
Gang Liu

Abstract Purpose In order to achieve the goal of rapid response, effective disposal and protection of life of large-scale radiation events, how to establish the uniform standard curve of biological dose estimation for chromosome aberration analysis becomes an urgent need. Methods Chromosomal aberrations with different irradiation dose rates were used to analyze the biological dose curve and the share of the “dicentric + ring” caused by the dose rate at each dose point. The dose-rate effect of 60Co-rays on peripheral blood lymphocytes was analyzed by statistical method . Results Irradiation dose is dominant ; At each dose point, “(dicentric chromosome + centric rings) /cell” is proportional to "dose rate", that is, Y = k X + b;Between 1-5Gy dose, “(dicentric chromosome + centric rings) /Cell ” holds a quadratic linear relationship with dose rate, that is,y = ax2 + bx + c. Conclusion The fraction of “dicentric + ring” caused by dose rate was calculated, if “Dose rate” is Z Gy•min− 1, it corresponds to an increase in linear relationships. Biological dose estimation curve :Y = 3.318 × 10− 3+2.0541 × 10− 2 x + 7.1721 × 10− 2x2(1.16Gy•min− 1༛R2 = 0.9997)(3).Dose rate :Y Dose rate = 1.2534 × 10− 2 x 2+6.6164 × 10− 2 x -2.732 × 10− 3༈0.01Gy•min− 1༛R2 = 0.999༉(1).The estimated dose is formula (3) – (1.16-Z) × formula (1).


2009 ◽  
Vol 67 (7-8) ◽  
pp. S218-S221 ◽  
Author(s):  
Y. Sakurai ◽  
H. Tanaka ◽  
M. Suzuki ◽  
Y. Kinashi ◽  
S. Masunaga ◽  
...  

1986 ◽  
Vol 25 (06) ◽  
pp. 235-238 ◽  
Author(s):  
S. Lander ◽  
M. Bahlo ◽  
R. Montz ◽  
R. Klapdor

The effects of radioimmunotherapy were tested in xenografts of 2 different human pancreatic carcinomas comparing the intravenous and intratumoral application. On principle, intravenous injections of high doses of 131l-anti- Ca 19-9 or -BW 494/32 may inhibit tumor growth. In view of the low direct radiation dose (360-2100 rad), however, other factors than direct toxic effects have to be discussed, e. g. systemic effects due to the high whole-body irradiation. Intratumoral application, however, may induce tumor regression or growth inhibition due to the high local irradiation dose. Consequently, this treatment modality might be of clinical value at least in some patients.


2019 ◽  
Vol 55 (5) ◽  
pp. 100-106
Author(s):  
Ye. N. Volkova ◽  
V. V. Belyayev ◽  
S. P. Prishlyak ◽  
A. A. Parkhomenko

Radiation ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 79-94
Author(s):  
Peter K. Rogan ◽  
Eliseos J. Mucaki ◽  
Ben C. Shirley ◽  
Yanxin Li ◽  
Ruth C. Wilkins ◽  
...  

The dicentric chromosome (DC) assay accurately quantifies exposure to radiation; however, manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. This study evaluates the throughput of high-performance ADCI (ADCI-HT) to stratify exposures of populations in 15 simulated population scale radiation exposures. ADCI-HT streamlines dose estimation using a supercomputer by optimal hierarchical scheduling of DC detection for varying numbers of samples and metaphase cell images in parallel on multiple processors. We evaluated processing times and accuracy of estimated exposures across census-defined populations. Image processing of 1744 samples on 16,384 CPUs required 1 h 11 min 23 s and radiation dose estimation based on DC frequencies required 32 sec. Processing of 40,000 samples at 10 exposures from five laboratories required 25 h and met IAEA criteria (dose estimates were within 0.5 Gy; median = 0.07). Geostatistically interpolated radiation exposure contours of simulated nuclear incidents were defined by samples exposed to clinically relevant exposure levels (1 and 2 Gy). Analysis of all exposed individuals with ADCI-HT required 0.6–7.4 days, depending on the population density of the simulation.


2021 ◽  
Vol 118 (21) ◽  
pp. 212101
Author(s):  
Alena Nikolskaya ◽  
Alexey Belov ◽  
Alexey Mikhaylov ◽  
Anton Konakov ◽  
David Tetelbaum ◽  
...  

Atmosphere ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 268
Author(s):  
Todd C. Harris ◽  
Laurent Vuilleumier ◽  
Claudine Backes ◽  
Athanasios Nenes ◽  
David Vernez

Epidemiology and public health research relating to solar ultraviolet (UV) exposure usually relies on dosimetry to measure UV doses received by individuals. However, measurement errors affect each dosimetry measurement by unknown amounts, complicating the analysis of such measurements and their relationship to the underlying population exposure and the associated health outcomes. This paper presents a new approach to estimate UV doses without the use of dosimeters. By combining new satellite-derived UV data to account for environmental factors and simulation-based exposure ratio (ER) modelling to account for individual factors, we are able to estimate doses for specific exposure periods. This is a significant step forward for alternative dosimetry techniques which have previously been limited to annual dose estimation. We compare our dose estimates with dosimeter measurements from skiers and builders in Switzerland. The dosimetry measurements are expected to be slightly below the true doses due to a variety of dosimeter-related measurement errors, mostly explaining why our estimates are greater than or equal to the corresponding dosimetry measurements. Our approach holds much promise as a low-cost way to either complement or substitute traditional dosimetry. It can be applied in a research context, but is also fundamentally well-suited to be used as the basis for a dose-estimating mobile app that does not require an external device.


Sign in / Sign up

Export Citation Format

Share Document