Periodic Breathing in Cardiopulmonary Exercise Testing: Exercise Oscillatory Ventilation in Heart Failure

2022 ◽  
Vol 19 (1) ◽  
pp. 120-126
Author(s):  
Steven J. Cassady ◽  
Danielle R. Glick ◽  
Sarah R. Williams ◽  
Gregory D. Lewis
2021 ◽  
Vol 28 (Supplement_1) ◽  
Author(s):  
P Garcia Bras ◽  
A Valentim Goncalves ◽  
J Reis ◽  
T Pereira Da Silva ◽  
R Ilhao Moreira ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Cardiopulmonary exercise testing (CPET) is used for risk stratification in patients with chronic heart failure (CHF). However, there is a lack of information regarding CPET prognostic power in patients under new HF therapies such as sacubitril/valsartan, Mitraclip, IV iron or SGLT2 inhibitors. The aim of this study was to evaluate the prognostic value of CPET parameters in a contemporary subset of patients with optimal medical and device therapy for CHF. Methods Retrospective evaluation of patients with CHF submitted to CPET in a tertiary center. Patients were followed up for 24 months for the composite endpoint of cardiac death, urgent heart transplantation or left ventricular assist device. CPET parameters, including peak oxygen consumption (pVO2) and VE/VCO2 slope, were analysed and their predictive power was measured. HF events were stratified according to cut-off values defined by the International Society for Heart and Lung Transplantation (ISHLT) guidelines: pVO2 of ≤12 mL/Kg/min and VE/VCO2 slope of >35. Results CPET was performed in 204 patients, from 2014 to 2018. Mean age was 59 ± 13 years, 83% male, with a mean left ventricular ejection fraction of 33 ± 8%, and a mean Heart Failure Survival Score of 8.6 ± 1.3. The discriminative power of CPET parameters is displayed in the Table. In patients with pVO2 ≤12 mL/Kg/min, the composite endpoint occurred in 18% of patients. A pVO2 value of ≤12 mL/Kg/min had a positive predictive power of 18% while pVO2 >12 had a negative predictive power of 93%. Regarding VE/VCO2 slope >35, the composite endpoint occurred in 13% of patients. A VE/VCO2 slope value of >35 had a positive predictive power of 13% while VE/VCO2 slope <35 had a negative predictive power or 94%. Conclusion Using ISHLT guideline cut-off values for advanced HF therapies patient selection, there was a reduced number of HF events (<20%) at 24 months in patients under optimal CHF therapy. While pVO2 and VE/VCO2 slope are still valuable parameters in risk stratification, redefining cut-off values may be necessary in a modern HF population. Discriminative power of CPET parameters Parameters HR; 95% CI AUC p-value Peak VO2 0.824 (0.728-0.934) 0.781 0.001 Percent of predicted pVO2 0.942 (0.907-0.978) 0.774 0.002 VE/VCO2 slope 1.068 (1.031-1.106) 0.756 0.008 Cardiorespiratory optimal point 1.118 (1.053-1.188) 0.746 0.004 PETCO2 maximum exercise 0.854 (0.768-0.950) 0.775 0.003 Ventilatory Power 0.358 (0.176-0.728) 0.796 0.002 HR Hazard ratio, AUC: Area under the curve, PETCO2: end-tidal CO2 pressure


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Greta Generati ◽  
Francesco Bandera ◽  
Marta Pellegrino ◽  
Valentina Labate ◽  
Eleonora Alfonzetti ◽  
...  

Background: In heart failure (HF) patients the severity of mitral regurgitation (MR) at rest has a well established prognostic value and its increase during exercise further adds to an increased risk. Our goal was to define the relationship between the degree of exercise MR severity with cardiopulmonary and echocardiographic related phenotypes in a cohort of HF patients. Methods: 71 HF reduced ejection fraction patients (mean age 67±11; male 72%; ischemic etiology 61%; NYHA class I, II, III and IV 13%, 36%, 39% and 12%, mean ejection fraction 33±9%) underwent cardiopulmonary exercise test (CPET) on tiltable cycle-ergometer combined with echocardiography at rest and during exercise. The population was divided into two groups according to the degree of functional peak MR: no to mild/moderate MR (no MR, MR1+ and MR2+) vs moderate/severe MR (MR3+ and MR4+). Results: A good correlation (ρ coefficient= 0.49) was found between the degree of dynamic MR and PASP at peak exercise. Despite similar echocardiographic profile at rest patients with significant peak MR (MR≥3+) had worse exercise performance (lower peak VO2, O2 pulse and workload) and impaired ventilatory efficiency (higher VE/VCO2 slope). Conclusions: In HF patients the severity of exercise-induced MR is associated with the most unfavorable performance and pulmonary hemodynamic response. A combined approach with CPET and echocardiographic assessment can help to early unmask and target functional MR and its related unfavorable phenotypes.


2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Christine Sailer ◽  
Hannah Edelmann ◽  
Cullen Buchanan ◽  
Pedro Giro ◽  
Matthew Babcock ◽  
...  

Background: Continuous-flow (CF) left ventricular assist devices (LVADs) improve outcomes for patients with advanced heart failure (HF). However, the lack of a physiological pulse predisposes to side-effects including uncontrolled blood pressure (BP), and there are little data regarding the impact of CF-LVADs on BP regulation. Methods: Twelve patients (10 males, 60±11 years) with advanced heart failure completed hemodynamic assessment 2.7±4.1 months before, and 4.3±1.3 months following CF-LVAD implantation. Heart rate and systolic BP via arterial catheterization were monitored during Valsalva maneuver, spontaneous breathing, and a 0.05 Hz repetitive squat-stand maneuver to characterize cardiac baroreceptor sensitivity. Plasma norepinephrine levels were assessed during head-up tilt at supine, 30 o and 60 o . Heart rate and BP were monitored during cardiopulmonary exercise testing. Results: Cardiac baroreceptor sensitivity, determined by Valsalva as well as Fourier transformation and transfer function gain of Heart rate and systolic BP during spontaneous breathing and squat-stand maneuver, was impaired before and following LVAD implantation. Norepinephrine levels were markedly elevated pre-LVAD and improved—but remained elevated post-LVAD (supine norepinephrine pre-LVAD versus post-LVAD: 654±437 versus 323±164 pg/mL). BP increased during cardiopulmonary exercise testing post-LVAD, but the magnitude of change was modest and comparable to the changes observed during the pre-LVAD cardiopulmonary exercise testing. Conclusions: Among patients with advanced heart failure with reduced ejection fraction, CF-LVAD implantation is associated with modest improvements in autonomic tone, but persistent reductions in cardiac baroreceptor sensitivity. Exercise-induced increases in BP are blunted. These findings shed new light on mechanisms for adverse events such as stroke, and persistent reductions in functional capacity, among patients supported by CF-LVADs. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03078972.