scholarly journals Evaluation of Creep Strength of Heterogeneous Welded Joint in HR6W Alloy and Sanicro 25 Steel

2017 ◽  
Vol 62 (4) ◽  
pp. 2057-2064 ◽  
Author(s):  
A. Zieliński ◽  
J. Dobrzański ◽  
H. Purzyńska ◽  
R. Sikora ◽  
M. Dziuba-Kałuża ◽  
...  

AbstractThis article presents the results of investigations on HR6W alloy and Sanicro 25 steel and the dissimilar welded joint made of them. The characteristic images of microstructure of the investigated materials in the as-received condition and following the creep test, observed with a scanning electron microscope (SEM), are shown. The X-ray analysis of phase composition of the existing precipitates was carried out. The method for evaluation of creep strength based on abridged creep tests carried out at a temperature higher than the design one is presented. The obtained results do not deviate from the values of creep strength determined in long-term creep tests. The maximum difference in creep strength of the investigated materials is ±20%, which is in compliance with the acceptable scatter band. The methodology presented can be used for verification of creep strength (life time) of the material of finished components to be operated under creep conditions.

2018 ◽  
Vol 140 (4) ◽  
Author(s):  
Seok Jun Kang ◽  
Hoomin Lee ◽  
Jae Boong Choi ◽  
Moon Ki Kim

Ultrasuper critical (USC) thermal plants are now in operation around the globe. Their applications include superheaters and reheaters, which generally require high temperature/pressure conditions. To withstand these harsh conditions, an austenitic heat-resistant HR3C (ASME TP310NbN) steel was developed for metal creep resistance. As the designed life time of a typical thermal plant is 150,000 h, it is very important to predict long-term creep behavior. In this study, a three-state variable continuum damage model (CDM) was modified for better estimation of long-term creep life. Accelerated uniaxial creep tests were performed to determine the material parameters. Also, the rupture type and microstructural precipitation were observed by scanning electron microscopy. The creep life of HR3C steel was predicted using only relatively short-term creep test data and was then successfully verified by comparison with the long-term creep data.


2003 ◽  
Vol 21 (2) ◽  
pp. 195-203 ◽  
Author(s):  
Kazuhiro KIMURA ◽  
Takashi WATANABE ◽  
Hiromichi HONGO ◽  
Masayoshi YAMAZAKI ◽  
Jun-ichi KINUGAWA ◽  
...  

Author(s):  
Takashi Wakai ◽  
Yuji Nagae ◽  
Takashi Onizawa ◽  
Satoshi Obara ◽  
Yang Xu ◽  
...  

This paper describes a proposal of provisional allowable stress for the welded joints made of modified 9Cr-1Mo steel (ASME Gr.91) applicable to the structural design of Japanese Sodium cooled Fast Reactor (JSFR). For the early commercialization of the SFRs, economic competitiveness is one of the most essential requirements. One of the most practical means to reduce the construction costs is to diminish the total amount of structural materials. To meet the requirements, modified 9Cr-1Mo steel has attractive characteristics as a main structural material of SFRs, because the steel has both excellent thermal properties and high temperature strength. Employing the steel to the main pipe material, remarkable compact plant design can be achieved. There is only one elbow in the hot leg pipe of the primary circuit. However, in such a compact piping, it is difficult to keep enough distance between welded joint and high stress portion. In the welded joints of creep strength enhanced ferritic steels including ASME Gr.91 (modified 9Cr-1Mo) steel, creep strength may obviously degrade especially in long-term region. This phenomenon is known as “Type-IV” damage. Though obvious strength degradation has not observed at 550°C yet for the welded joint made of modified 9Cr-1Mo steel, it is proper to suppose strength degradation must take place in very long-term creep. Therefore, taking strength degradation due to “Type-IV” damage into account, the allowable stress applicable to JSFR pipe design was proposed based on creep rupture test data acquired in temperature accelerated conditions. Available creep rupture test data of welded joints made of modified 9Cr-1Mo steel provided by Japanese steel vender were collected. The database was analyzed by region partition method. The creep rupture data were divided into two regions of short-term and long-term and those were individually evaluated by regression analyses with Larson Miller Parameter (LMP). Boundary condition between short-term and long-term was half of 0.2% proof stress of base metal at corresponding temperature. First order equation of logarithm stress was applied. For conservativeness, allowable stress was proposed provisionally considering design factor for each region. Present design of JSFR hot leg pipe of primary circuit was evaluated using the proposed allowable stress. As a result, it was successfully demonstrated that the compact pipe design was assured. For validation of the provisional allowable stress, a series of long-term creep tests were started. In future, the provisional allowable stress will be properly reexamined when longer creep rupture data are obtained. In addition, some techniques to improve the performance of welded joints were surveyed and introduced.


2017 ◽  
Vol 270 ◽  
pp. 183-188
Author(s):  
Dagmar Jandová

Conventional (CCT) and accelerated (ACT) creep tests of a weld joint made of COST F and COST FB2 steels were carried out over a temperature range from 550 °C to 650 °C. Fracturing of the crept specimens was located in the heat affected zone (HAZ) of the F steel. Two specimens were selected after CCT and ACT for quantitative evaluation of the precipitates and compared to the weld joint in as-received conditions. Scanning and transmission electron micrographs were used to measure the precipitate size. Both methods were compared and the accuracy of the results was discussed. It was concluded that ACT can simulate the precipitation of chromium carbides and structure recovery during long term creep exposures. However, precipitation of Laves phase during CCT was not recorded after ACT. Therefore, it is difficult to use ACT in this experiment for estimating the long term creep strength.


Author(s):  
Leonardo Cipolla ◽  
Augusto Di Gianfrancesco ◽  
Dario Venditti ◽  
Giuseppe Cumino ◽  
Stefano Caminada

In the last two decades the service pressure and temperature of components for advanced power plants increased significantly and more severe requirements on strength, corrosion resistance and creep properties were imposed on high temperature steels. To comply with these requirements, several new 9–12%Cr martensitic steels were developed and some of them, such as ASTM Grades 91, 911 and 92 are currently used in new high efficiency Ultra Super Critical power plants. The initial evaluation of their creep strength above 550°C was defined with relatively short term tests, but the long experience in service and long term creep laboratory tests showed that the original estimation of creep strength values were not reliable and a reduction of the creep resistance occurred at long service time. Short creep tests (elaborated with time-temperature-parameter methods, i.e. Larson Miller equation) usually give an over-estimation of the long-term creep properties of 9%Cr steels. The results of the creep assessments of Grade 92 (Japanese NF616) are an example of the significant lowering of the creep properties: the creep resistance of this grade was initially evaluated in 600°C/160MPa/105h by means extrapolation of short creep tests, within 103 hours; recently the creep strength was reduced down to 113MPa (ECCC assessment, 2005). Moreover some premature failures of Japanese Grade PI 22 took place and similar problems appeared on other 12%Cr steels. The lowering of creep strength in 9–12%Cr steels at long times is a consequence of the evolution of their microstructure during high temperature service. The causes of this phenomenon in Grades 91, 911 and 92 are examined in this article, paying special attention to the metallurgical explanation. The most evident changes in the microstructure of 9%Cr steels occur with the nucleation of Laves-phase as well as the nucleation of Z-phase at longer times. The precipitation of Laves phase has two relevant aspects by the creep strength point of view. On one hand, high amounts of Mo and W contents are incorporated in this phase, causing a depletion of these elements from the solid solution and thus a reduction of their contribution to the overall creep resistance. On the other hand, the increased volume fraction of secondary phases leads to a higher precipitation strengthening during the first precipitation phase: at the beginning, the precipitation of fine Laves phase increases the creep resistance; however if the coarsening rate is not taken under control, the mean diameter of these particles reaches micrometric dimensions with a detrimental effect on creep behaviour within 103 hours in the range 600°C–650°C. The high coarsening rate of Laves phase is therefore the major cause of the lowering of creep properties of Grades 91, 911 and 92. Coarsening of Laves phase particles over a critical size triggers the cavity formation and the consequent brittle intergranular fracture. Transition from ductile fracture to brittle intergranular fracture often occurs in long-term creep at the onset of coarsening of Laves particles, which result to be the preferential site for cavities nucleation in the 9%Cr steels. Z-phase was recognized in 9%Cr steels after long term exposure, but in far smaller amount than on 12%Cr steels: no dramatic drop in volume fraction of MX was observed in association to the nucleation of this phase, therefore it is believed that the modified Z-phase does not affect significantly the long term creep properties of Grades 91, 911 and 92. The dimple pattern is typical of ductile fracture, which occurs for short service period (hence highest stress). At low stresses, cavities are formed at the triple grain junctions at which Laves particles are often found, causing wedge crack, otherwise isolated cavities can form independently at coarse Laves phase particles (Figure 13). The latter type is often observed after long-term creep in the interganular fracture region. In both cases, brittle fracture occurs at the onset of coarsening of Laves particles, which result to be the preferential site for cavities nucleation in the 9%Cr steels.


Author(s):  
Masatsugu Yaguchi ◽  
Sosuke Nakahashi ◽  
Koji Tamura

A creep strength of welded joint of ASME Grade 91 steel in a region exceeding 100,000 hours was examined in this work. Creep tests were conducted on the steel used at USC plants for long-term, and remaining creep life of the material for operating condition was calculated on a fitting curve using Larson-Miller parameter. Total creep life of the material, which means a creep life at initial state, was presumed to be a summation of the service time at the plants and the remaining creep life. The estimation was conducted for welded joints used at five plants for long-term, and all results lay within 99% confidential band by the creep life evaluation curve of the material proposed by Japanese committee in 2015, while a significant heat-heat variation of creep strength was found even in the region exceeding 100,000 hours. Creep tests on base metals related to each welded joint were also conducted, and the estimation results of the total creep life of the base metals were compared to those of the welded joints. It was suggested that the heat-heat variation of the welded joints eminently depends on the creep life property of the corresponding base metal.


2016 ◽  
Vol 2016 (0) ◽  
pp. S0810104 ◽  
Author(s):  
Masatsugu YAGUCHI ◽  
Kaoru NAKAMURA ◽  
Sosuke NAKAHASHI

Author(s):  
Kenji Kako ◽  
Susumu Yamada ◽  
Masatsugu Yaguchi ◽  
Yusuke Minami

Type IV damage has been found at several ultra-supercritical (USC) plants that used high-chromium martensitic steels in Japan, and the assessment of the remaining life of the steels is important for electric power companies. The assessment of the remaining life needs long-term creep data for over 10 years, but such data are limited. We have attempted to assess the remaining life by creep tests and by microstructural observation of Grade 91 steels welded pipes which were used in USC plants for over 10 years. Following the results of microstructural observation of USC plant pipes, we find that microstructures, especially distribution of MX precipitates, have large effect on the creep life of Grade 91 steels.