scholarly journals The Influence of Crown Ferrule on Fracture Resistance of Endodontically Treated Maxillary Central Incisors

2017 ◽  
Vol 21 (1) ◽  
pp. 44-49
Author(s):  
Sasho Jovanovski ◽  
Julie Popovski ◽  
Alesh Dakskobler ◽  
Ljubo Marion ◽  
Peter Jevnikar

SummaryBackground: Prefabricated zirconia posts can contribute to increasing the fracture resistance of the endodontically treated teeth. Purpose. This in vitro study compared the fracture resistance of endodontically treated central maxillary incisors prepared with 2 mm ferrule length to the ones without ferrule.Material and methods: Twenty-four caries-free maxillary central incisors were divided into 2 groups of 12. In group A circumferential external dentin shoulders were prepared for 2 mm external dentin ferrule length. There was no ferrule preparation in Group B. Zirconia VALLPOST BO-S (Ø 1,6 mm), Ljubljana, Slovenia were used with retention forms in the coronary part. Core build-up was made of pressed ceramics (IPS e.max Press, Ivoclar, Liechtenstein). Crowns were manufactured from the same ceramic material (IPS e.max Press, Ivoclar). After root canal treatment and post space preparation, all posts were cemented with an adhesive resin cement (Multilink Automix, Ivoclar). The specimens were embedded in acrylic resin blocks (ProBase Polymer/Monomer, Ivoclar) and loaded at an angle of 45° to the long axis in an Instron Testing Machine 4301 (Instron Corp., USA) at a crosshead speed of 1 mm/min until fracture. Fracture patterns and loads were recorded. A significance level of p<0.05 was used for all comparisons. Two-way analysis of variance was used for statistical analysis. Failure patterns were analyzed with the optical microscope Stereo Discovery V.8 (Carl Zeiss, Germany) and compared using the chi-square nonparametric test.Results: The mean values (±SD) of fracture loads (N) for the Groups A and B were 664.63N (±49.14) and 519.36N (±71.65) recpectively. Significantly lower failure loads were recorded for the specimens in the group B. Failure patterns within the groups revealed non-catastrophic failure in 70% of the specimens for group A and 85% for group B.Conclusions: Within the limitations of this in vitro study, it can be concluded that zirconia VALLPOST BO-S (Ø 1,6 mm) with press-ceramic cores and crowns, can be used for restoration of endodontically treated teeth. The teeth prepared with 2 mm external dentin ferrule length were found to be more fracture resistant than teeth without ferrule.

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Zahraa Abdulaali Al-Ibraheemi ◽  
Huda Abbas Abdullah ◽  
Nada Abdlameer Jawad ◽  
Julfikar Haider

During restorative treatment, premolars restored with resin filling materials using the conventional incremental-fill technique take longer restoration time and undermine the integrity of the tooth. The aim of this study was to assess fracture resistance of premolars restored by various types of novel bulk-fill composite resin materials. Forty-eight (n = 48) freshly extracted sound maxillary first premolars were used in this in vitro study. The teeth were divided into six groups, each having 8 specimens. Group A (positive control) was allocated for the intact teeth. For specimens in Groups B to F, a large cavity (Class-II MOD) was prepared with a standardized dimension of cavity (3 mm depth on the pulpal floor, 4 mm at the gingival seat, and 3 mm cavity width). Group B represented prepared teeth without any restoration. Group C, Group D, Group E, and Group F were restored with Tetric EvoCeram® incremental-fill (conventional), Beautifil bulk-fill, Filtek posterior bulk-fill, and SonicFill 2 bulk-fill restorative materials, respectively. All samples were finished and polished with an enhanced finishing kit and stored in distilled water for a month before the fracture resistance testing. All the samples were exposed to the axial loading (the speed of crosshead was 1 mm/min) in a computer-controlled universal testing machine (LARYEE, China) via a steel bar (6 mm in diameter) and the maximum applied force in Newton was recorded as the fracture resistance. One-way analysis of variance (SPSS 21) was used to compare the fracture resistance within the groups, and Tukey’s post hoc test was used to determine the difference between the groups. The lowest value of fracture resistance was recorded for Group B, and the highest value was recorded for Group A followed by the values of Group D, Group C, Group F, and Group E. One-way ANOVA revealed a statistically significant difference between the groups ( P < 0.05 ). Nonsignificant difference was found between the premolars restored by bulk-fill and conventional composites. Among the bulk-fill restored specimens, Beautifil restorative demonstrated significantly higher fracture resistance in comparison with the other two bulk-fill restored specimen groups (SonicFill 2 and Filtek). Bulk-fill composite such as Beautifil could be an alternative option to conventional incremental-fill composite for premolar restoration.


2018 ◽  
Vol 6 (9) ◽  
pp. 1707-1711
Author(s):  
Rami M. Atia ◽  
Nada Omar ◽  
Haidy Nabil ◽  
Yousra Aly

OBJECTIVE: The aim of this in vitro study was to assess the effect of obturation technique and cementation timings on the bonding of fibre-reinforced posts to the root canal walls. METHODS: Twenty extracted teeth were randomly allocated to two groups according to the obturation technique and cementation timing. Central incisors with single canals were used after being decoronated. Every extracted tooth of the {vertical compaction group} (VC) group (n = 10) had been obturated using the {E & Q plus obturation system} with posts cemented in the same day; The other (CO) conventional group (n = 10) teeth were obturated using the conventional lateral compaction technique and posts cemented after one week. “SF“ Fiber posts were used after bonding and cementation using Rely X ARC resin cement with all the endodontically treated teeth. The push-out test was performed in a universal testing machine. Data were analysed by 2 way analysis of variance with Statistical significance was set to 0.05. RESULTS: Heat softened gutta percha group showed more push out the bond strength of the bonded posts than the conventional obturation group (p < 0.05). In the middle region, there was no statistical significance between the two groups while there was significance in the coronal and apical thirds. CONCLUSION: The vertical compaction technique and early cementation improved the bond strength of the resin posts in comparison to the conventional obturation technique with late cementation.


2012 ◽  
Vol 9 (2) ◽  
pp. 185 ◽  
Author(s):  
Vajihesadat Mortazavi ◽  
Najmeh Katiraei ◽  
Hamid Badrian ◽  
Mohammadhossein Fathi ◽  
Shirin Shahnaseri ◽  
...  

2017 ◽  
Vol 05 (01) ◽  
pp. 039-046 ◽  
Author(s):  
Monica Sharma ◽  
Ajay Bansal ◽  
Sunny Panthi ◽  
Shefali Malik ◽  
Atulya Sharma

Abstract Purpose: The purpose of this in vitro study was to evaluate marginal fit of cobalt- chromium (Co-Cr) copings fabricated by direct metal laser sintering system (DMLS) and conventional lost-wax technique (LW). Materials and method: Forty tooth preparations were carried out over extracted mandibular molars. They were divided into two groups A and B of 20 each. For group A Co-Cr copings were fabricated by direct metal laser sintering (DMLS) and for group B by lost wax technique (LW). Glass –ionomer cement (GIC) was used to tack the copings over their preparations. Marginal fit was then evaluated directly under the stereomicroscope. Results: The mean marginal gap of group A was 27.9 ± 2.4 μm and group B was 40.4 ±6 μm. Statistical analysis using t - test showed highly significant difference (P>.05) between the marginal mean of the DMLS (group A) compared to LW (group B). Conclusion: The DMLS copings demonstrated superior marginal fit compared to that of conventional Co-Cr casted copings.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Basawaraj Biradar ◽  
Sudharani Biradar ◽  
Arvind MS

Objectives. The objective of this in vitro study was to investigate whether weight gain or loss in the three different composites occurs due to water absorption when they are stored in water.Methods. The composite restorative materials selected for this study included a microfine hybrid (Synergy) and two nanofilled composite restorative materials (Ceram X and Filtek Supreme Ultra). Twenty specimens of each material were fabricated of each composite material. Group A: Filtek Supreme Ultra, Group B: Synergy, Group C: Ceram X. Then all the specimens were stored in 10 ml Distilled water containing test tubes and placed in incubator at 37°C for six weeks. The weight changes of these specimens were measured daily for the first week and later once a week for next five weeks by using an electrical analytical balance.Results.The data was analyzed by one-way analysis of variance and Student'sttest. All groups showed maximum amount of water absorption in the first week than gradual decrease in the water absorption from the second to the sixth week, as compared to the first week and there is no statistically significant difference between the groups tested.Conclusion. All the composite restorative material absorbs some amount of water. The water absorption of the composite may decrease the physical and mechanical properties of the composites; hence it is necessary to consider the type of the material before starting the treatment.


Sign in / Sign up

Export Citation Format

Share Document