Determination of the Length of Sedimentation Reaction (Erythrocyte Sedimentation Rate) in Non-Anticoagulated Blood with the Microtest 1

Author(s):  
Elisa Piva ◽  
Paolo Fassina ◽  
Mario Plebani
PEDIATRICS ◽  
1960 ◽  
Vol 25 (1) ◽  
pp. 106-111
Author(s):  
Aree Valyasevi ◽  
Joseph M. Sloan ◽  
Lewis A. Barness

C-reactive protein in the serum and the erythrocyte sedimentation rate were followed serially in 13 patients with acute nephritis and in 9 patients with the nephrotic syndrome. Although a positive C-reactive protein test was always associated with evidence of infection, obvious infection in a few instances was not accompanied by a positive test. Determination of C-reactive protein is valuable in determining the presence of infection in patients with acute nephritis and the nephrotic syndrome, especially in the latter where hormone therapy may mask many signs of infection.


Author(s):  
Kamal Preet ◽  
Vyankatesh T. Anchinmane ◽  
Shilpa Sankhe

Background: Erythrocyte sedimentation rate (ESR) test provides valuable information in screening, diagnosis, as well as monitoring disease activity and therapeutic response in numerous health conditions. The most commonly used method for determination of ESR is Westergren method, which is time-consuming and requires a large amount of blood sample. There are several other methods, like Micro-ESR method which overcome the limitations of conventional Westergren method, hence the present study was performed to compare results of Westergren method with Micro-ESR method for determination of ESR.Methods: In the present study, blood samples from 100 patients were processed for ESR determination by Westergren method and Micro-ESR method. The results obtained were compared using Pearson’s correlation test.Results: The Westergren method was the reference method and the Micro-ESR method was testing method. The comparison was done between Micro- ESR method results (X-axis) and results of Westergren method (Y-axis). The slope of the regression line using linear regression was 1.010 with a y-intercept of -0.788. Statistical analysis demonstrated significant correlation of results of Micro-ESR method with Westergren method (r = 0.9977).Conclusions: Micro-ESR is a reliable and precise method for ESR measurement. The Micro- ESR method is simple to perform and requires very small volume of blood (0.2ml) as compared to conventional Westergren method. It can be potential useful tool in performing ESR determination especially for the patients with limitation of blood availability as pediatric patients and very old patients. 


2020 ◽  
Vol 14 (6) ◽  
pp. 064108
Author(s):  
Sumit Kumar ◽  
Rishi Ram ◽  
Arnab Sarkar ◽  
Sunando DasGupta ◽  
Suman Chakraborty

Author(s):  
Şeyda Özdemir ◽  
Gülfer Öztürk ◽  
Aynur Altuntaş ◽  
Sümeyya Akyol ◽  
Erdem Bulut ◽  
...  

2019 ◽  
Vol 72 (10) ◽  
pp. 716-719
Author(s):  
Ivana Lapić ◽  
Elisa Piva ◽  
Federica Spolaore ◽  
Giulia Musso ◽  
Francesca Tosato ◽  
...  

Ves-Matic CUBE 200 is an automated erythrocyte sedimentation rate (ESR) analyser based on the modified Westergren principle of measurement. In this study, we aimed to assess its analytical performance following the key points addressed by the International Council for Standardization in Haematology and the comparability with the gold standard Westergren method. Comparison of the two methods yielded a correlation coefficient of 0.852, no significant bias and a small constant difference between compared results. Intrarun coefficients of variation (CV) ranged from 2.2% to 22.2%, the higher being for lower ESR values, while inter-run CVs were 19.7% for the normal range and 3.0% for the abnormal range. This study proved the analytical validity of the Ves-Matic CUBE 200 and its high comparability with the Westergren method, showing obvious improvements in the technology applied for automated determination of ESR and a valuable step forward in standardisation of ESR methods.


Sign in / Sign up

Export Citation Format

Share Document