Unsteady MHD natural convection flow of a nanofluid inside an inclined square cavity containing a heated circular obstacle

Author(s):  
M. A. Mansour ◽  
Rama Subba Reddy Gorla ◽  
Sadia Siddiqa ◽  
A. M. Rashad ◽  
T. Salah

Abstract The phenomena of unsteady magnetohydrodynamics (MHD) natural convection flow in an inclined square cavity filled with nanofluid and containing a heated circular obstacle at its center with heat generation/absorption impact are examined numerically. The cavity’s right and left walls are maintained at low temperatures, while the remaining walls are adiabatic. The volumetric external force, MHD, is applied across the inclined cavity. A penalty formulation-based finite element method is used to solve the nonlinear set of governing equations iteratively. The numerical scheme and results are validated through a comparison with the benchmark results, and it shows that our solutions are in good agreement with them. The results are shown in terms of contours of streamlines, isotherms, and average Nusselt number. It is observed that MHD alters the streamlines, isotherms, and average Nusselt number and dominates the flow as compared to any other physical parameter. The average Nusselt number is found sensitive to the central obstacle’s size, and it reduces sufficiently when the radius of the inner cylinder increases. For all the parameters, the streamlines’ symmetric pattern holds, such that the anti-clockwise cells on the left side of the cavity have their symmetric clockwise cells on the right side.

2011 ◽  
Vol 7 (2) ◽  
pp. 37-50 ◽  
Author(s):  
Md. Mustafizur Rahman ◽  
M. Arif Hasan Mamun ◽  
M. Masum Billah ◽  
Saidur Rahman

In this study natural convection flow in a square cavity with heat generating fluid and a finite size heater on the vertical wall have been investigated numerically. To change the heat transfer in the cavity, a heater is placed at different locations on the right vertical wall of the cavity, while the left wall is considered to be cold. In addition, the top and bottom horizontal walls are considered to be adiabatic and the cavity is assumed to be filled with a Bousinessq fluid having a Prandtl number of 0.72. The governing mass, momentum and energy equations along with boundary conditions are expressed in a normalized primitive variables formulation. Finite Element Method is used in solution of the normalized governing equations. The parameters leading the problem are the Rayleigh number, location of the heater, length of the heater and heat generation. To observe the effects of the mentioned parameters on natural convection in the cavity, we considered various values of heater locations, heater length and heat generation parameter for different values of Ra varying in the range 102 to 105. Results are presented in terms of streamlines, isotherms, average Nusselt number at the hot wall and average fluid temperature in the cavity for the mentioned parameters. The results showed that the flow and thermal fields through streamlines and isotherms as well as the rate of heat transfer from the heated wall in terms of Nusselt number are strongly dependent on the length and locations of the heater as well as heat generating parameter.DOI: 10.3329/jname.v7i2.3292 


2014 ◽  
Vol 136 (6) ◽  
Author(s):  
M. Saleem ◽  
M. A. Hossain ◽  
Suvash C. Saha

Double diffusive Marangoni convection flow of viscous incompressible electrically conducting fluid in a square cavity is studied in this paper by taking into consideration of the effect of applied magnetic field in arbitrary direction and the chemical reaction. The governing equations are solved numerically by using alternate direct implicit (ADI) method together with the successive over relaxation (SOR) technique. The flow pattern with the effect of governing parameters, namely the buoyancy ratio W, diffusocapillary ratio w, and the Hartmann number Ha, is investigated. It is revealed from the numerical simulations that the average Nusselt number decreases; whereas the average Sherwood number increases as the orientation of magnetic field is shifted from horizontal to vertical. Moreover, the effect of buoyancy due to species concentration on the flow is stronger than the one due to thermal buoyancy. The increase in diffusocapillary parameter, w causes the average Nusselt number to decrease, and average Sherwood number to increase.


2019 ◽  
Vol 29 (11) ◽  
pp. 4130-4141 ◽  
Author(s):  
Abdulmajeed Mohamad ◽  
Mikhail A. Sheremet ◽  
Jan Taler ◽  
Paweł Ocłoń

Purpose Natural convection in differentially heated enclosures has been extensively investigated due to its importance in many industrial applications and has been used as a benchmark solution for testing numerical schemes. However, most of the published works considered uniform heating and cooling of the vertical boundaries. This paper aims to examine non-uniform heating and cooling of the mentioned boundaries. The mentioned case is very common in many electronic cooling devices, thermal storage systems, energy managements in buildings, material processing, etc. Design/methodology/approach Four cases are considered, the left-hand wall’s temperature linearly decreases along the wall, while the right-hand wall’s temperature is kept at a constant, cold temperature. In the second case, the left-hand wall’s temperature linearly increases along the wall, while the right-hand wall’s temperature is kept a constant, cold temperature. The third case, the left-hand wall’s temperature linearly decreases along the wall, while the right-hand wall’s temperature linearly increases along the wall. In the fourth case, the left-hand and the right-hand walls’ temperatures decrease along the wall, symmetry condition. Hence, four scenarios of natural convection in enclosures were covered. Findings It has been found that the average Nusselt number of the mentioned cases is less than the average Nusselt number of the uniformly heated and cooled enclosure, which reflects the physics of the problem. The work quantifies the deficiency in the rate of the heat transfer. Interestingly one of the mentioned cases showed two counter-rotating horizontal circulations. Such a flow structure can be considered for passively, highly controlled mechanism for species mixing processes application. Originality/value Previous works assumed that the vertical boundary is subjected to a constant temperature or to a sinusoidal varying temperature. The subject of the work is to examine the effect of non-uniformly heating and/or cooling vertical boundaries on the rate of heat transfer and flow structure for natural convection in a square enclosure. The temperature either linearly increases or decreases along the vertical coordinate at the boundary. Four scenarios are explored.


1988 ◽  
Vol 110 (1) ◽  
pp. 116-125 ◽  
Author(s):  
P. A. Litsek ◽  
A. Bejan

The natural convection flow and heat transfer between two enclosures that communicate through a vertical opening is studied by considering the evolution of an enclosed fluid in which the left half is originally at a different temperature than the right half. Numerical experiments show that at sufficiently high Rayleigh numbers the ensuing flow is oscillatory. This and other features are anticipated on the basis of scale analysis. The time scales of the oscillation, the establishment of thermal stratification, and eventual thermal equilibrium are determined and tested numerically. At sufficiently high Rayleigh numbers the heat transfer between the communicating zones is by convection, in accordance with the constant-Stanton-number trend pointed out by Jones and Otis (1986). The range covered by the numerical experiments is 102 < Ra < 107, 0.71 < Pr < 100, and 0.25 < H/L < 1.


2018 ◽  
Vol 14 (5) ◽  
pp. 1064-1081
Author(s):  
Basant Kumar Jha ◽  
Michael O. Oni

PurposeThe purpose of this paper is to investigate the impact of time-periodic thermal boundary conditions on natural convection flow in a vertical micro-annulus.Design/methodology/approachAnalytical solution in terms of Bessel’s function and modified Bessel’s function of order 0 and 1 is obtained for velocity, temperature, Nusselt number, skin friction and mass flow rate.FindingsIt is established that the role of Knudsen number and fluid–wall interaction parameter is to decrease fluid temperature, velocity, Nusselt number and skin friction.Research limitations/implicationsNo laboratory practical or experiment was conducted.Practical implicationsCooling device in electronic panels, card and micro-chips is frequently cooled by natural convection.Originality/valueIn view of the amount of works done on natural convection in microchannel, it becomes interesting to investigate the effect that time-periodic heating has on natural convection flow in a vertical micro-annulus. The purpose of this paper is to examine the impact of time-periodic thermal boundary conditions on natural convection flow in a vertical micro-annulus.


2008 ◽  
Author(s):  
Esam M. Alawadhi

Natural convection flow in a cube with a heated strip is solved numerically. The heated strip is attached horizontally to the front wall and maintained at high temperature, while the entire opposite wall is maintained at low temperature. The heated strip simulates an array of electronic chips The Rayleigh numbers of 104, 105, and 106 are considered in the analysis and the heated strip is horizontally attached to the wall. The results indicate that the heat transfer strongly depends on the position of the heated strip. The maximum Nusselt number can be achieved if the heater is placed at the lower half of the vertical wall. Increasing the Rayleigh number significantly promotes heat transfer in the enclosure. Flow streamlines and temperature contours are presented, and the results are validated against published works.


Sign in / Sign up

Export Citation Format

Share Document