Comparison of Two Bioelectrical Impedance Analysis Devices With Dual Energy X-ray Absorptiometry and Magnetic Resonance Imaging in the Estimation of Body Composition

2013 ◽  
Vol 27 (1) ◽  
pp. 236-243 ◽  
Author(s):  
Ji-Guang Wang ◽  
Yi Zhang ◽  
Han-E Chen ◽  
Yan Li ◽  
Xiao-Guang Cheng ◽  
...  
1999 ◽  
Vol 96 (6) ◽  
pp. 647-657 ◽  
Author(s):  
N. J. FULLER ◽  
C. R. HARDINGHAM ◽  
M. GRAVES ◽  
N. SCREATON ◽  
A. K. DIXON ◽  
...  

Magnetic resonance imaging (MRI) was used to evaluate and compare with anthropometry a fundamental bioelectrical impedance analysis (BIA) method for predicting muscle and adipose tissue composition in the lower limb. Healthy volunteers (eight men and eight women), aged 41 to 62 years, with mean (S.D.) body mass indices of 28.6 (5.4) kg/m2 and 25.1 (5.4) kg/m2 respectively, were subjected to MRI leg scans, from which 20-cm sections of thigh and 10-cm sections of lower leg (calf) were analysed for muscle and adipose tissue content, using specifically developed software. Muscle and adipose tissue were also predicted from anthropometric measurements of circumferences and skinfold thicknesses, and by use of fundamental BIA equations involving section impedance at 50 kHz and tissue-specific resistivities. Anthropometric assessments of circumferences, cross-sectional areas and volumes for total constituent tissues matched closely MRI estimates. Muscle volume was substantially overestimated (bias: thigh, -40%; calf, -18%) and adipose tissue underestimated (bias: thigh, 43%; calf, 8%) by anthropometry, in contrast to generally better predictions by the fundamental BIA approach for muscle (bias: thigh, -12%; calf, 5%) and adipose tissue (bias: thigh, 17%; calf, -28%). However, both methods demonstrated considerable individual variability (95% limits of agreement 20–77%). In general, there was similar reproducibility for anthropometric and fundamental BIA methods in the thigh (inter-observer residual coefficient of variation for muscle 3.5% versus 3.8%), but the latter was better in the calf (inter-observer residual coefficient of variation for muscle 8.2% versus 4.5%). This study suggests that the fundamental BIA method has advantages over anthropometry for measuring lower limb tissue composition in healthy individuals.


2018 ◽  
Author(s):  
Carla M Prado ◽  
Camila LP Oliveira ◽  
M Cristina Gonzalez ◽  
Steven B Heymsfield

Body composition assessment is an important tool in both clinical and research settings able to characterize the nutritional status of individuals in various physiologic and pathologic conditions. Health care professionals can use the information acquired by body composition analysis for the prevention and treatment of diseases, ultimately improving health status. Here we describe commonly used techniques to assess body composition in healthy individuals, including dual-energy x-ray absorptiometry, bioelectrical impedance analysis, air displacement plethysmography, and ultrasonography. Understanding the key underlying concept(s) of each assessment method, as well as its advantages and limitations, facilitates selection of the method of choice and the method of the compartment of interest. This review contains 5 figures, 3 tables and 52 references Key words: air displacement plethysmography, bioelectrical impedance analysis, body composition, disease, dual-energy x-ray absorptiometry, health, muscle mass, nutritional status, obesity, sarcopenia, ultrasound fat mass


Sign in / Sign up

Export Citation Format

Share Document