Development of a Knee-gap Force Measurement Device to Evaluate Quantitative Lower Limb Muscular Strength of the Elderly

2010 ◽  
Vol 130 (2) ◽  
pp. 267-274 ◽  
Author(s):  
Kazuhiko Yamashita ◽  
Kazuya Imaizumi ◽  
Yumi Iwakami ◽  
Mitsuru Sato ◽  
Sawako Nakajima ◽  
...  
Geriatrics ◽  
2020 ◽  
Vol 5 (4) ◽  
pp. 83
Author(s):  
Valentina Bullo ◽  
Enrico Roma ◽  
Stefano Gobbo ◽  
Federica Duregon ◽  
Manuele Bergamo ◽  
...  

Sarcopenia and muscle strength reduction are a frequent disorder in non-communicable chronic diseases. The aims of this study are: (a) to verify if the absolute and relative to body weight muscle strength of lower limb is affected by the presence of pathology; (b) to verify if the trends are different among knee and ankles joints. One-hundred and forty-five elderly were recruited (16 liver transplant recipients, 48 kidney transplant recipients, 52 elderly with obesity, 30 healthy elderly). Muscular strength of lower limb was evaluated. Evaluation protocol included maximal isometric knee extension, maximal isokinetic knee extension and flexion, maximal isokinetic ankle (both right and left) extension and flexion. A statistically significant interaction between measurement and group membership was found for absolute strength measure (F (4.23, 170.56) = 3.316, p = 0.011, partial η2 (η2p) = 0.076), and relative strength measure(F (4.44, 174.72) = 16.407, p < 0.01, partial η2 (η2p) = 0.294). Elderly patients living with kidney transplants showed the lower level of absolute muscular strength, while relative muscular strength is mainly lacking in the elderly with obesity. The strength profile of elderly subjects is affected by obesity, liver transplantation, and kidney transplantation.


2013 ◽  
Vol 24 ◽  
pp. 1360028
Author(s):  
DONG KI KIM ◽  
JEONG TAE LEE

This paper presents a force measurement system that can measure a lower-body muscular strength of skaters. The precise measurement and analysis of the left and right lower-body strength of skaters is necessary, because a left/right lower-body strength balance is helpful to improve the athletes' performance and to protect them from injury. The system is constructed with a skate sliding board, a couple of sensor-units with load cell, indicator and control box, guard, force pad, and support bracket. The developed force measurement system is calibrated by the calibration setup, and the uncertainty of the force sensing unit on the left is within 0.087% and the uncertainty of the force sensing unit on the right is within 0.109%. In order to check the feasibility of the developed measurement device, a kinematic analysis is conducted with skater. As a result, the subject shows the deviation of left and right of 12.1 N with respect to average strength and 39.1 N with respect to the maximum strength. This evaluation results are reliable enough to make it possible to measure a lower-body muscular strength of skaters. The use of this measurement system will be expected to correct the posture of skaters and record the sports dynamics data for each athlete. It is believed that through the development of this equipment, skaters in elementary, middle, high schools, colleges, and the professional level have the systematic training to compete with world-class skaters.


Author(s):  
Eun Mi Jang ◽  
So Hyun Park

(1) Background—The application of neuromuscular electrical stimulation (NMES) combined with low-intensity exercise to the elderly can be more efficient than low-intensity exercise only in terms of delaying the loss of muscle mass. We aimed to assess the adjunct of NMES to low-intensity lower limb strengthening exercise to prevent falls in frail elderly for a relatively short period of 4 weeks. (2) Methods—Thirty elderly women aged 65 or above were randomly categorized into three groups: control group (CON, n = 8), exercise group (EX, n = 10), and NMES with exercise group (EX + NMES, n = 9). The exercise group took part in a lower limb strengthening exercise program for one hour three times a week for four weeks. Furthermore, the NMES with exercise group had added NMES stimulation when exercising. The limbs’ muscle mass, body fat mass, calf circumference, grip force, five times sit-to-stand test, timed up-and-go test (TUG), one-leg stand test, and Y-balance test (YBT) were evaluated at baseline and 4 weeks after. (3) Results—Comparisons between the three groups showed that the TUG was significantly decreased and the YB was significantly increased in NMES with exercise group (p < 0.05). (4) Conclusions—These results suggested that a combination of NMES stimulation and exercises was more helpful in strengthening balance than exercises alone in the short term.


2015 ◽  
Vol 221 ◽  
pp. 1-8 ◽  
Author(s):  
Takuma Iwasaki ◽  
Toshihiro Takeshita ◽  
Yuji Arinaga ◽  
Koji Uemura ◽  
Hideyuki Ando ◽  
...  

Author(s):  
Kshitij Vadake ◽  
Jie Cui

Experimental Fluid Dynamics (EFD) and Computational Fluid Dynamics (CFD) have been instrumental in Fluid Mechanics to help solve scientific and engineering problems. This research attempts to use both techniques to perform a parametric study of turbulence flow around airfoil ClarkY-14 at various velocity and angle of attack (AoA). Clark Y-14 airfoil was designed in the 1920’s. It demonstrated good overall performance at low and moderate Reynolds numbers. With the progress in the aviation field, its performance was sub-optimal for newer aircraft designs. However, with the advent of RC airplanes and model aircrafts, there is a renewed interest in this airfoil. Various research projects have been conducted using this airfoil, but there hasn’t been a combined EFD and CFD study of the performance characteristics of the airfoil itself, which still finds real world applications today. One important aspect of this research included the investigation of the effects of a Force Measurement Device/Sensor, which is typically used in scaled/full-size wind tunnels to mount the test model as well as measure the forces/moments acting on it during the testing. The presence of such a device could affect the quality of the data obtained from the wind tunnel testing when compared to a real world application scenario where the aforementioned device may not be present. To the best of the author’s knowledge, no detailed study has been published on the effects of such devices. In this study, the results with and without the measuring device were generated by using CFD simulations. The results were then compared to see to what extent the inclusion of these devices will affect the results. The methodology used for this research was experimental as well as computational. In the present research, a commercially available CFD software STAR-CCM+ was employed to simulate the flows around airfoil Clark Y-14. The experimental data was obtained from wind tunnel tests using AEROLAB Educational Wind Tunnel (EWT) and compared with the simulation data from the CFD. The two data sets were in good agreement. Both experimental and simulation results were used to understand the effects of the measurement device/sensor used in the scaled wind tunnel on the lift and drag coefficients of the airfoil. Two separate CFD simulation setups were designed to model the presence and absence of the measurement device/sensor. These setups replicated the wind tunnel setup. The airfoil was tested and simulated at different speeds as well as different AoA. The comparative study gave a useful insight on the accuracy of the CFD simulations in relation to the actual testing. The analysis of results concluded that the force measurement device/sensor had insignificant effects on the accuracy and quality of data collected through wind tunnel testing.


Sign in / Sign up

Export Citation Format

Share Document