Structural integrity and progressive collapse in large-panel precast concrete structural systems

PCI Journal ◽  
2008 ◽  
Vol 53 (4) ◽  
pp. 55-61 ◽  
Author(s):  
Ned M. Cleland
Vestnik MGSU ◽  
2021 ◽  
pp. 1015-1033
Author(s):  
Viktor V. Tur ◽  
Andrei V. Tur ◽  
Aliaksandr A. Lizahub

Introduction. The robustness requirements should be fulfilled already at the stage of conceptual design of the structural system, taking into account the use of various strategies for its protection from progressive collapse. Compared to monolithic reinforced concrete structural systems, precast concrete systems are more susceptible to the effects of accidental actions. To ensure the integrity of the damaged system in the original prefabricated structural system, it is necessary to provide (reserve) a sufficient number of horizontal (internal and perimetric) and vertical ties with the required degree of continuity and plastic deformability. Materials and methods. Analytical models of the resistance of horizontal ties based on the equations of the energy balance of the system. Results. On a real example of a prefabricated floor, calculations of the required parameters of horizontal ties were performed according to the proposed dependencies, based on the model of the energy balance of the system and the design models included in the standards of various countries. Comparison of the results obtained showed that the calculation models of the norms in a number of cases can give an unsafe result, underestimating the required cross-sectional area of horizontal ties. This is due to the fact that all dependencies for calculating the tie forces are based on constant values of the ultimate deflection (usually from 1/6 to 1/10 of the span) without checking the limiting deformability of horizontal ties. Conclusions. Deformability of ties is one of the basic parameters that should be monitored when checking the robustness of structural systems made of precast concrete. The proposed method, based on the provisions of the energy balance, makes it possible to take into account the limiting deformability of horizontal ties when determining the membrane (chain) forces and calculate the maximum dynamic response of the damaged structural system.


PCI Journal ◽  
1976 ◽  
Vol 21 (3) ◽  
pp. 46-69 ◽  
Author(s):  
Mark Fintel ◽  
Donald M. Schultz

Vestnik MGSU ◽  
2020 ◽  
pp. 1513-1522
Author(s):  
Natalia V. Fedorova ◽  
Vu Ngoc Tuyen ◽  
Igor A. Yakovenko

Introduction. Problem solving focused on the protection of buildings and structures from progressive collapse and minimization of resources, needed for this purpose, is becoming increasingly important. In many countries, including Russia, this type of protection is incorporated into national regulatory documents, and, therefore, any research, aimed at developing effective ways to protect structural systems from progressive collapse under special actions, is particularly relevant. In this regard, the present article aims to formulate effective strength criteria for such anisotropic materials as reinforced concrete to analyze plane stressed reinforced concrete structures exposed to sudden structural transformations caused by the removal of one of bearing elements. Materials and methods. To solve this problem, a variant of the generalized theory of plasticity of concrete and reinforced concrete, developed by G.A. Geniev, is proposed for application to the case of variable loading of a plane stressed reinforced concrete element. The acceptability of generalization of the strength criterion, pursuant to the theory of plasticity of concrete and reinforced concrete under static loading, and the applicability of this criterion to variable static-dynamic loading of reinforced concrete are used as the main hypothesis. An algorithm of an approximate method is presented as a solution to this problem; it allows to analyze the considered stress-strain state of plane stressed reinforced concrete elements. Results. The numerical analysis of the obtained solution, compared with the results of the experimental studies, was used to evaluate the designed strength criterion for reinforced concrete elements located in the area where the column is connected to the girder of a monolithic reinforced concrete frame in case of a sudden restructuring of a structural system. It is found out that the qualitative nature of the destruction pattern of the area under research, obtained in experiments, corresponds to the destruction pattern, identified by virtue of the analysis performed using the proposed criterion. Conclusions. The variant of the reinforced concrete strength criterion designated for the variable loading of a plane stressed reinforced concrete element and an algorithm for its implementation, based on the theory of plasticity of concrete and reinforced concrete developed by G.A. Geniev, is applicable to the analysis of a special limit state of reinforced concrete elements of structural systems of frames of buildings and structures.


2020 ◽  
Vol 214 ◽  
pp. 110675 ◽  
Author(s):  
Yun Zhou ◽  
Xiang Hu ◽  
Yilin Pei ◽  
Hyeon-Jong Hwang ◽  
Taiping Chen ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-23
Author(s):  
Noor Azim Mohd Radzi ◽  
Roszilah Hamid ◽  
Azrul A. Mutalib ◽  
A. B. M. Amrul Kaish

Fire exposure can have a significant impact on the structural integrity and robustness of precast concrete beam-to-column connections. Given the importance of fire safety in the design of a structure, it is critical to understand the damage that may occur in the event of a fire to be able to prevent the building from collapsing. No comprehensive study has been carried out to determine the effects of fire on semirigid and pinned concrete beam-to-column connections. Most studies focused on the impact of exposure of rigid concrete beam-to-column connections to high temperatures. This paper is a comprehensive review of the literature on the performance of precast concrete beam-to-column connections under fire conditions. The key areas in this review are the moment-rotation-temperature characteristics and fire effect on precast concrete beam-to-column connections. This paper focuses primarily on the case studies of real fires, large-scale fire tests, computer simulations and analytical models, fire resistance tests on the connection elements, and assessment and rehabilitation of fire-damaged precast concrete. The paper also discusses the current issues and possible challenges.


2015 ◽  
Vol 77 (12) ◽  
Author(s):  
Ahmad Baharuddin Abd Rahman ◽  
Tan Kee Hong ◽  
Izni Syahrizal Ibrahim ◽  
Roslli Noor Mohamed

Precast concrete building system has gained its popularity in Malaysia because of the many advantages such as high quality of structural components, less labour intensive at the construction site, and shorter completion time of a project. One of the constraints in precast concrete structures is to ensure that the connections are strong enough to ensure the structural integrity and robustness of the overall frames. In this study, a total of nine rectangular steel splice-sleeve connections were tested experimentally under incremental tensile loads. Two steel plates were inserted and welded to each end of the steel splice-sleeve. The steel plates act as shear key to provide the interlocking mechanism to the grout and to enhance the bond property between the grout and the splice. These plates were adopted to prevent the grout slippage from the sleeve. The grout strength, embedded steel bar lengths and the size of the steel sleeve splice were varied among the specimens to study their effect on the tensile performance of the connection. The results showed that the higher strength of grout, longer embedded length of steel bar and smaller size of the sleeve contributes to a higher ultimate tensile load.


2016 ◽  
Vol 691 ◽  
pp. 376-387 ◽  
Author(s):  
Ivan Hollý ◽  
Ivan Harvan

The structural integrity of precast concrete structures depends mainly on the connections between the precast structural elements. The purpose of a connection is to transfer loads, restrain movement, and/or to provide stability to a component or an entire structure. Therefore, the design of connections is one of the most important aspects in the design of precast concrete structures. All connections should design with valid codes. Every precasters have developed connection details over the years that suit their particular production and erection preferences. It is common, that the structural engineer to show loads and connection locations and allow the successful manufacturer’s engineering department to provide the final design and details of the connections.