scholarly journals Paradigmaváltás szükségessége a sugárterápiában

2015 ◽  
Vol 156 (44) ◽  
pp. 1763-1768
Author(s):  
Árpád Mayer ◽  
Csilla Katona ◽  
Róbert Farkas ◽  
Zsuzsa Póti

The status and indications of radiotherapy have significantly changed in the past decade because novel techniques, radiobiological research and major advances in informatics have made better local control possible. Using supplemented marking of the target volume with computer tomography based other image-making methods adapted made it possible to define the tumor and intact surrounding tissues more precisely. With novel radiotherapy techniques the dosage of the homogenity and the covering in the target volume can be raised optimally, especially with intensity modulated arc radiotherapy (volumetric modulated arc therapy) without causing radiation injury or damage to intact surrounding tissues. Furthermore, with novel techniques and target volume marking, new indications have appeared in clinical practice and besides sterotactic radiotherapy for intracranial metastases, the extracranial so-called oligometastic conditions can be maintained close to a curative state (or in remission) for many years. Among these, perhaps the most striking is the stereotactic radiotherapy treatment of liver, lung and spinal cord metastases in one or more fractions, for which the indispensable condition is the image or respiratory guided technique. Orv. Hetil., 2015, 156(44), 1763–1768.

Author(s):  
Karthikeyan Kalyanasundaram ◽  
Subramani Vellaiyan

Abstract Purpose: The purpose of the study was to evaluate the impact of changes in breathing pattern inside the breath-hold window (BHW) during deep inspiration breath hold treatment for carcinoma left breast patients post-conservative surgery. Methods: Ten patients of carcinoma left breast post-conservative surgery were prospectively selected. Three sets of CT plain images were acquired, one with 5 mm deep inspiration BHW (DIBHR) and the other one with 1 mm BHW matching the lower threshold (DIBHL) and the third one with 1 mm BHW matching the upper threshold (DIBHH) as DIBHR. For all patients, forward intensity-modulated radiotherapy (FIMRT) and volumetric modulated arc therapy (VMAT) plans were generated in the 5 mm BHW CT series and the same plan being copy and pasted in other series. Target volume doses and critical structure doses were tabulated. Results: Planning target volume coverage was adequate and no significant differences were found in any CT series. Significant differences noted in average left lung V5%, V10% and V18% doses between DIBHR versus DIBHH (p values = 0·0461, 0·0283 and 0·0213, respectively) and DIBHL versus DIBHH (p values = 0·0434, 0·0484 and 0·0334, respectively) for FIMRT plans and V18% doses in DIBHR versus DIBHH (p = 0·0067) in VMAT. No differences in heart and apex of heart doses were found. Left anterior descending artery (LAD) mean doses were significant in DIBHL versus DIBHR, DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0012, 0·0444 and 0·0048, respectively) series for FIMRT plans and DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0341, 0·0001) for VMAT plans. Finding: The changes in the breathing pattern inside DIBH window level cause some variation in LAD doses and no other significant differences in any parameters noted, so care should be taken while treating patients with preexisting cardiac conditions.


2021 ◽  
Vol 18 (2) ◽  
Author(s):  
Magdalena Charmacińska ◽  
Sara Styś ◽  
Olga Bąk ◽  
Weronika Kijeska ◽  
Agnieszka Skrobała

Nowotwór piersi jest to nowotwór złośliwy powstający z komórek gruczołu piersiowego, który rozwija się miejscowo w piersi oraz daje przerzuty do węzłów chłonnych i narządów wewnętrznych (płuc, wątroby, kości i mózgu). Ponad 23% zachorowań na nowotwory kobiet w Polsce, jak i na świecie stanowią nowotwory piersi. Na przestrzeni ostatnich lat techniki napromieniania nowotworów piersi ulegają ciągłemu rozwojowi. Celem pracy było poglądowe przedstawienie technik radioterapeutycznych stosowanych w napromienianiu nowotworów piersi, od dwuwymiarowej 2D techniki statycznej poprzez techniki dynamiczne (IMRT technika z modulacją intensywnością dawki (ang. intensity modulated radiation therapy), VMAT technika obrotowa z modulacją intensywności dawki (ang. volumetric modulated arc therapy), aż do techniki DIBH techniki napromieniania na głębokim wstrzymanym wdechu (ang. deep inspiration breath hold). W pracy skupiono się na przedstawieniu realizacji omawianych technik i opisie jak dana technika wpływa na rozkład dawki w planowanej objętości do napromieniania PTV (ang. Planning Target Volume) oraz na dawki w narządach krytycznych w radioterapii nowotworów piersi.


2021 ◽  
Vol 20 ◽  
pp. 153303382098586
Author(s):  
Tomoki Mizuno ◽  
Natsuo Tomita ◽  
Taiki Takaoka ◽  
Masashi Tomida ◽  
Hiroshi Fukuma ◽  
...  

Objective: We compared radiotherapy plans among helical tomotherapy (HT), volumetric-modulated arc therapy (VMAT), and intensity-modulated proton therapy (IMPT) for angiosarcoma of the scalp (AS). Methods: We conducted a planning study for 19 patients with AS. The clinical target volume (CTV) 1 and CTV2 were defined as the gross tumor volume with a specific margin and total scalp, respectively. For HT and VMAT, the planning target volume (PTV) 1 and PTV2 were defined as CTV1 and CTV2 with 0.5-cm margins, respectively. For IMPT, robust optimization was used instead of a CTV-PTV margin (i.e. CTV robust). The targets of the HT and VMAT plans were the PTV, whereas the IMPT plans targeted the CTV robust. In total, 70 Gy and 56 Gy were prescribed as the D95% (i.e. dose to 95% volume) of PTV1 (or CTV1 robust) and PTV2 (or CTV2 robust), respectively, using the simultaneous integrated boost (SIB) technique. Other constraint goals were also defined for the target and organs at risk (OAR). Results: All dose constraint parameters for the target and OAR met the goals within the acceptable ranges for the 3 techniques. The coverage of the targets replaced by D95% and D98% were almost equivalent among the 3 techniques. The homogeneity index of PTV1 or CTV1 robust was equivalent among the 3 techniques, whereas that of PTV2 or CTV2 robust was significantly higher in the IMPT plans than in the other plans. IMPT reduced the Dmean of the brain and hippocampus by 49% to 95%, and the Dmax of the spinal cord, brainstem, and optic pathway by 70% to 92% compared with the other techniques. Conclusion: The 3 techniques with SIB methods provided sufficient coverage and satisfactory homogeneity for the targets, but IMPT achieved the best OAR sparing.


2016 ◽  
Vol 16 (1) ◽  
pp. 101-108 ◽  
Author(s):  
Upendra Kumar Giri ◽  
Biplab Sarkar ◽  
Kanan Jassal ◽  
Anusheel Munshi ◽  
Tharmar Ganesh ◽  
...  

AbstractObjectiveThis study was conducted for comparison of techniques between volumetric modulated arc therapy (VMAT), forward-planning intensity-modulated radiotherapy (FIMRT) and conventional technique for left-sided breast radiotherapy after conservative surgery.MethodsIn all, 20 postoperative left breast carcinoma patients were included in this study. In all plans the planning target volume (PTV) was the breast tissue with appropriate margin as per our institutional protocol. The contouring was done on a Monaco Sim (V5.00.02) contouring workstation. All patient were planned using partial arc VMAT in Monaco treatment planning system (TPS) (V5.00.02) and treated on Elekta Synergy linear accelerator. The 3D conformal radiotherapy (3DCRT) and FIMRT planning were done in CMS XIO (V5.00.01.1) TPS. The 3DCRT planning consisted of conventional medial and tangential wedge portals with multileaf collimator field shaping conforming to the target volume. For all the plans generated the following metrics were scored: V105%, V100%, V95%, mean dose (for PTV), V5%, V20%, D2cc and mean dose (for organs at risk).ResultsThe mean PTV volume for 20 patients was 1,074·6±405·1 cc. The highest PTV dose coverage was observed in the 3DCRT technique with 94·1±1·8% of the breast PTV receiving 95% of the prescription dose (V95%). However, it was also observed that this technique resulted in 21·3±10% of the PTV receiving more than 105% of the prescription dose (V105%), which was highest among the three techniques. In contrast, VMAT yielded lowest V95% of 93·0±1·8 and 3·3±5·5% of V105%.ConclusionThis study concluded equivalent result between FIMRT and VMAT. However, VMAT was found to be the choice of radiotherapy technique as it produces lesser dose distribution to heart compared with any other technique.


2016 ◽  
Vol 15 (3) ◽  
pp. 263-268 ◽  
Author(s):  
James C. L. Chow ◽  
Runqing Jiang ◽  
Alexander Kiciak ◽  
Daniel Markel

AbstractBackgroundWe demonstrated that our proposed planning target volume (PTV) dose–volume factor (PDVF) can be used to evaluate the PTV dose coverage between the intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans based on 90 prostate patients.PurposePDVF were determined from the prostate IMRT and VMAT plans to compare their variation of PTV dose coverage. Comparisons of the PDVF with other plan evaluation parameters such as D5%, D95%, D99%, Dmean, conformity index (CI), homogeneity index (HI), gradient index (GI) and prostate tumour control probability (TCP) were carried out.Methods and materialsProstate IMRT and VMAT plans using the 6 MV photon beams were created from 40 and 50 patients, respectively. Dosimetric indices (CI, HI and GI), dose–volume points (D5%, D95%, D99% and Dmean) and prostate TCP were calculated according to the PTV dose–volume histograms (DVHs) of the plans. All PTV DVH curves were fitted using the Gaussian error function (GEF) model. The PDVF were calculated based on the GEF parameters.ResultsFrom the PTV DVHs of the prostate IMRT and VMAT plans, the average D99% of the PTV for IMRT and VMAT were 74·1 and 74·5 Gy, respectively. The average prostate TCP were 0·956 and 0·958 for the IMRT and VMAT plans, respectively. The average PDVF of the IMRT and VMAT plans were 0·970 and 0·983, respectively. Although both the IMRT and VMAT plans showed very similar prostate TCP, the dosimetric and radiobiological results of the VMAT technique were slightly better than IMRT.ConclusionThe calculated PDVF for the prostate IMRT and VMAT plans agreed well with other dosimetric and radiobiological parameters in this study. PDVF was verified as an alternative of evaluation parameter in the quality assurance of prostate treatment planning.


Author(s):  
Munirathinam Natraj ◽  
P. N. Pawaskar ◽  
Arun Chairmadurai

Abstract Aim: We have investigated the influence in volumetric-modulated arc therapy (VMAT) plans by a sequence of increment of gantry angle (IGA) in definitive radiotherapy treatment for cervical cancer. The plans are quantitatively analysed in terms of conformity index (CI), heterogeneity index (HI), dose–gradient index (DGI), target coverage (TC) by prescription dose, monitor unit (MU) usage, control points (CPs) and dose to organs. Materials and Methods: In this retrospective study, we selected 27 patients with cervical cancer having aged between 54 and 69. All the patients enrolled in this study were at T3N1M0 stage of cervical cancer. The prescription dose to planning target volume (PTV) was 50 Gy and was administered in 2 Gy/fraction through VMAT technique. VMAT plans were optimised by varying the parameter ‘IGA’ as 10, 20, 30 and 40°. Results: Homogenous dose distribution within PTV and TC by prescription dose was significantly enhanced (p < 0·05) with larger IGA. The difference between volume receiving 15 Gy (V15Gy) in bowel was up to 10% with larger IGA (30 and 40°) and V25Gy in femoral head was up to 3% with smaller IGA (10 and 20°). CPs were enhanced and MU usage was reduced with larger IGA (30 and 40°). IGA 40° had reduced the MU usage than IGA 30° but the CI and DGI were compromised due to large MLC field segments. Conclusion: This study recommends that the larger IGA could yield better results when the number of sectors is even, for a cervical cancer patient. However, more data from more patients need to be obtained and analysed to make this an evidence-based hypothesis.


2020 ◽  
Vol 61 (3) ◽  
pp. 499-505 ◽  
Author(s):  
Takuya Uehara ◽  
Hajime Monzen ◽  
Mikoto Tamura ◽  
Kazuki Ishikawa ◽  
Hiroshi Doi ◽  
...  

Abstract The present study aimed to evaluate whether knowledge-based plans (KBP) from a single optimization could be used clinically, and to compare dose–volume histogram (DVH) parameters and plan quality between KBP with (KBPCONST) and without (KBPORIG) manual objective constraints and clinical manual optimized (CMO) plans for pharyngeal cancer. KBPs were produced from a system trained on clinical plans from 55 patients with pharyngeal cancer who had undergone intensity-modulated radiation therapy or volumetric-modulated arc therapy (VMAT). For another 15 patients, DVH parameters of KBPCONST and KBPORIG from a single optimization were compared with CMO plans with respect to the planning target volume (D98%, D50%, D2%), brainstem maximum dose (Dmax), spinal cord Dmax, parotid gland median and mean dose (Dmed and Dmean), monitor units and modulation complexity score for VMAT. The Dmax of spinal cord and brainstem and the Dmed and Dmean of ipsilateral parotid glands were unacceptably high for KBPORIG, although the KBPCONST DVH parameters met our goal for most patients. KBPCONST and CMO plans produced comparable DVH parameters. The monitor units of KBPCONST were significantly lower than those of the CMO plans (P &lt; 0.001). Dose distribution of the KBPCONST was better than or comparable to that of the CMO plans for 13 (87%) of the 15 patients. In conclusion, KBPORIG was found to be clinically unacceptable, while KBPCONST from a single optimization was comparable or superior to CMO plans for most patients with head and neck cancer.


Author(s):  
Maija Rossi ◽  
Eeva Boman

Abstract Aim: Studying the use of Aperture Shape Controller (ASC) and Convergence Mode (CM) in Eclipse (Varian Medical System) in terms of plan quality and complexity of volumetric modulated arc therapy (VMAT). Materials and methods: Forty VMAT plans were re-optimised for the prostate, prostate + lymph nodes, breast and head & neck patients retrospectively, changing the ASC settings (off, moderate, very high) and CM settings (off, on and extended). Results: Using ‘on’ or ‘extended’ CM increased plan quality in terms of planning target volume homogeneity and low-dose spread to the organs at risk (OAR). ‘Extended’ CM increased the optimisation time 4·3-fold compared to ‘on’, and deteriorated the plan quality in several simple planning cases. ‘Moderate’ ASC decreased plan complexity with minor effect on plan quality compared to ‘off’, but ‘very high’ ASC had larger adverse dosimetric effects. However, the ASC decreased the plan complexity only if the CM was turned ‘on’. Findings: Using ‘on’ CM increases the plan quality but using ‘extended’ CM is not recommended. The ‘moderate’ ASC decreased complexity without significant adverse effects on plan quality, and even ‘very high’ ASC may be used when plan simplicity is prioritised. However, if CM is not used, the ASC should also be turned off.