Diffusion of OH− during hydration of YBa2Cu3O7-y by exposing to water vapor

1990 ◽  
Vol 5 (1) ◽  
pp. 17-21 ◽  
Author(s):  
Yasuro Ikuma ◽  
Masahiro Yoshimura ◽  
Shigeru Kabe

The hydration of YBa2Cu3O7-y in water vapor was investigated at various values of y and at two different PH2O by measuring the weight of the specimen. The reaction was relatively insensitive to the values of y and was extensive in the water vapor pressure of 2.7 kPa at room temperature and 140 °C. This was due to the decomposition of YBa2Cu3O7-y by reacting with H2O. The weight gain was also detected in the water vapor pressure of 270 Pa. The weight gain under lower water vapor pressure was supposed to be controlled by diffusion of OH− in YBa2Cu3O7-y. The diffusion coefficient calculated from the measurement was compared favorably with the oxygen diffusion coefficient.

Author(s):  
V. R. Matricardi ◽  
G. G. Hausner ◽  
D. F. Parsons

In order to observe room temperature hydrated specimens in an electron microscope, the following conditions should be satisfied: The specimen should be surrounded by water vapor as close as possible to the equilibrium vapor pressure corresponding to the temperature of the specimen.The specimen grid should be inserted, focused and photo graphed in the shortest possible time in order to minimize dehydration.The full area of the specimen grid should be visible in order to minimize the number of changes of specimen required.There should be no pressure gradient across the grid so that specimens can be straddled across holes.Leakage of water vapor to the column should be minimized.


1998 ◽  
Vol 37 (4-5) ◽  
pp. 171-175
Author(s):  
Artem Khlebnikov ◽  
Falilou Samb ◽  
Paul Péringer

p-toluenesulphonic acid degradation by Comamonas testosteroni T-2 in multi-species biofilms was studied in a fixed bed biofilm reactor. The polypropylene static mixer elements (Sulzer Chemtech Ltd., Switzerland) were used as a support matrix for biofilm formation. Biofilm respiration was estimated using the dynamic gassing-out oxygen uptake method. A strong relation between oxygen uptake and reactor degradation efficiency was observed, because p-toluenesulphonate degradation is a strictly aerobic process. This technique also allowed us to estimate the thickness of the active layer in the studied system. The mean active thickness was in order of 200 μm, which is close to maximum oxygen penetration depth in biofilms. A transient mathematical model was established to evaluate oxygen diffusitivity in non-steady-state biofilms. Based on the DO concentration profiles, the oxygen diffusion coefficient and the maximum respiration activity were calculated. The oxygen diffusion coefficient obtained (2 10−10-1.2 10−9 m2 s−1) is in good agreement with published values. The DO diffusion coefficient varied with biofilm development. This may be, most likely, due to the biofilm density changes during the experiments. The knowledge of diffusivity changes in biofilms is particularly important for removal capacity estimation and appropriate reactor design.


1995 ◽  
Vol 393 ◽  
Author(s):  
B. Ma ◽  
J.-H. Park ◽  
C. U. Segre ◽  
U. Balachandran

ABSTRACTOxides in the Sr-Fe-Co-O system exhibit both electronic and ionic conductivities. Recently, the Sr-Fe-Co-O system attracted great attention because of its potential to be used for oxygen-permeable membranes that can operate without electrodes or external electrical circuitry. Electronic and ionic conductivities of two compositions of the Sr-Fe-Co-O system, named SFC-1 and SFC-2, have been measured at various temperatures. The electronic transference number is much greater than the ionic transference number in SFC-1, whereas the electronic and ionic transference numbers are very similar in SFC-2. At 800°C, the electronic and ionic conductivities are ≈76 and ≈4 S•cm−1, respectively, for SFC-1; whereas, for SFC-2, the electronic and ionic conductivities are ≈10 and ∼1 S•cm−1, respectively. By performing a local fitting to the equation σ • T = Aexp(-Ea / kT), we found that the oxide ion activation energies are 0.92 and 0.37 eV, respectively, for SFC-1 and SFC-2. The oxygen diffusion coefficient of SFC-2 is ≈ 9 x 10−7cm2/sec at 900°C.


Sign in / Sign up

Export Citation Format

Share Document