Tensile Testing of Ultra-Thin-Film Materials Deposited on Polyimide for Mems Applications

1998 ◽  
Vol 518 ◽  
Author(s):  
J.H. Tregilgas ◽  
M. Strumpell

AbstractA newly developed approach to thin-film tensile testing has been utilized for evaluating ultra-thin-films of about 60-100 nm in thickness. Thin sputtered metal films deposited on 3.5 gm thick polyimide film substrates were tested using a Mesotronix nanotensiometer. Modifications to sample handling and zero strain calibration helped to improve testing reproducibility. The response of a thin-film metal was determined by subtracting the response of the polyimide carrier film from that of the metal-on-polyimide composite. Stress-strain curves for two amorphous alloys sputtered from Al-25 at% Ti and Nb-25 at% Al targets exhibited well-defined elastic regions followed by brittle behavior. The ultimate tensile strengths (UTS) were about 1200 MPa for the Al-Ti and 1700 MPa for the Nb-Al, both of which occurred near the elastic strain limit of about 2%. After recrystallization at 280°C for an hour, the Al-Ti film showed what appears to be an upper and lower yield point, in addition to strain hardening. Initial yielding occurred at a strain of about 1.2% and a stress of about 800 MPa, while the UTS of about 1000-1060 MPa occurs at strains as high as 9%. Stress relaxation measurements performed on both the amorphous and the recrystallized films showed lower values of stress relaxation at 1% strain compared to low alloy polycrystalline Al films.

1986 ◽  
Vol 6 (2) ◽  
pp. 85-105 ◽  
Author(s):  
Arthur W. Birley ◽  
Kamal P. Fernando ◽  
Mohammed Tahir

1975 ◽  
Vol 48 (5) ◽  
pp. 944-952 ◽  
Author(s):  
S. H. Kalfayan ◽  
R. H. Silver ◽  
A. A. Mazzeo

Abstract The accelerated aging of a vulcanizate of fluorosilicone rubber was studied by four methods: infrared spectroscopy, GPC, weight loss, and stress relaxation, with the object of gathering information pertinent to understanding the basic mechanism of its aging. No changes were observed in infrared spectra of the rubber aged in air up to 315°C although severe degradation took place, as evidenced by high weight loss and drastic change in the physical condition of the test samples. It was concluded that although the polymer degrades, there is no change detectable within the precision of the analytical methods in the structure of the repeat unit of the elastomer. The gel-permeation chromatogram of unheated rubber showed peaks at MW 450 000 (95%) and 630 (5%). The low-molecular-weight component is very likely the cyclic tetramer of λ,λ′,λ″-trifluoropropylmethylsiloxane, the principal monomer of the FVMQ used. Heat aging increased the concentration of the 630 MW component, but rate studies were prevented by complications resulting from solvent-induced rubber degradation. Rapid decrease in the MW of FVMQ, as found by GPC, indicated random scission in the polymer backbone, as opposed to ordered unzipping of the repeat unit. The same conclusion was reached from the effects of crosslink density on stress relaxation. Activation energies obtained from weight-loss measurements (104 kJ/mol) were lower than those obtained from stress-relaxation measurements, (150–155 kJ/mol), suggesting that the processes being measured in each case may not be the same. Chemical stress relaxation takes place more rapidly in the presence of air than in an inert atmosphere, and intermittent stress-relaxation measurements indicate that crosslinks form during thermal aging in air, their rate first increasing and then decreasing.


Shinku ◽  
2006 ◽  
Vol 49 (3) ◽  
pp. 162-164 ◽  
Author(s):  
Yukiko OKANO ◽  
Shuichi TAJIRI ◽  
Takashi AOZONO ◽  
Akio OKAMOTO ◽  
Soichi OGAWA ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document