scholarly journals Wireless communication with implanted medical devices using the conductive properties of the body

2011 ◽  
Vol 8 (4) ◽  
pp. 427-433 ◽  
Author(s):  
John E Ferguson ◽  
A David Redish
2020 ◽  
Vol 10 (8) ◽  
pp. 2923 ◽  
Author(s):  
Jean-Pierre Alcaraz ◽  
Gauthier Menassol ◽  
Géraldine Penven ◽  
Jacques Thélu ◽  
Sarra El Ichi ◽  
...  

We discuss the perspectives of designing implantable medical devices that have the criterion of being symbiotic. Our starting point was whether the implanted device is intended to have any two-way (“duplex”) communication of energy or materials with the body. Such duplex communication extends the existing concepts of a biomaterial and biocompatibility to include the notion that it is important to consider the intended functional use of the implanted medical device. This demands a biomimetic approach to design functional symbiotic implantable medical devices that can be more efficient in mimicking what is happening at the molecular and cellular levels to create stable interfaces that allow for the unfettered exchanges of molecules between an implanted device and a body. Such a duplex level of communication is considered to be a necessary characteristic of symbiotic implanted medical devices that are designed to function for long periods of time inside the body to restore and assist the function of the body. We illustrate these perspectives with experience gained from implanting functional enzymatic biofuel cells.


2020 ◽  
Vol 48 (3) ◽  
pp. 867-879
Author(s):  
Geraldine Penven ◽  
Gauthier Menassol ◽  
Jean-Pierre Alcaraz ◽  
François Boucher ◽  
Jacques Thélu ◽  
...  

In 1968 Wolfson et al. published the concept for producing energy inside the body using catalytic electrodes exposed to the body fluid as an electrolyte and utilising naturally occurring fuels such as glucose. Since then, the technology has advanced to enhance the levels of power using enzymes immobilised within three-dimensional bioelectrodes that are nanostructured. Current research in the field of enzymatic fuel cells is directed toward applying electrochemical and nanostructural expertise to increase the energy density, to increase the power density, to increase the operational stability, and to increase the voltage output. Nonetheless, biocompatibility remains the major challenge for increasing the life-time for implanted enzymatic biofuel cells. Here, we discuss the current issues for biocompatibility and suggest directions to enhance the design of biofuel cells so as to increase the life-time of implantation whilst maintaining sufficient performance to provide power for implanted medical devices.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Hanjun Ryu ◽  
Hyun-moon Park ◽  
Moo-Kang Kim ◽  
Bosung Kim ◽  
Hyoun Seok Myoung ◽  
...  

AbstractSelf-powered implantable devices have the potential to extend device operation time inside the body and reduce the necessity for high-risk repeated surgery. Without the technological innovation of in vivo energy harvesters driven by biomechanical energy, energy harvesters are insufficient and inconvenient to power titanium-packaged implantable medical devices. Here, we report on a commercial coin battery-sized high-performance inertia-driven triboelectric nanogenerator (I-TENG) based on body motion and gravity. We demonstrate that the enclosed five-stacked I-TENG converts mechanical energy into electricity at 4.9 μW/cm3 (root-mean-square output). In a preclinical test, we show that the device successfully harvests energy using real-time output voltage data monitored via Bluetooth and demonstrate the ability to charge a lithium-ion battery. Furthermore, we successfully integrate a cardiac pacemaker with the I-TENG, and confirm the ventricle pacing and sensing operation mode of the self-rechargeable cardiac pacemaker system. This proof-of-concept device may lead to the development of new self-rechargeable implantable medical devices.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mayukh Nath ◽  
Shovan Maity ◽  
Shitij Avlani ◽  
Scott Weigand ◽  
Shreyas Sen

AbstractRadiative communication using electromagnetic fields is the backbone of today’s wirelessly connected world, which implies that the physical signals are available for malicious interceptors to snoop within a 5–10 m distance, also increasing interference and reducing channel capacity. Recently, Electro-quasistatic Human Body Communication (EQS-HBC) was demonstrated which utilizes the human body’s conductive properties to communicate without radiating the signals outside the body. Previous experiments showed that an attack with an antenna was unsuccessful at a distance more than 1 cm from the body surface and 15 cm from an EQS-HBC device. However, since this is a new communication modality, it calls for an investigation of new attack modalities—that can potentially exploit the physics utilized in EQS-HBC to break the system. In this study, we present a novel attack method for EQS-HBC devices, using the body of the attacker itself as a coupling surface and capacitive inter-body coupling between the user and the attacker. We develop theoretical understanding backed by experimental results for inter-body coupling, as a function of distance between the subjects. We utilize this newly developed understanding to design EQS-HBC transmitters that minimizes the attack distance through inter-body coupling, as well as the interference among multiple EQS-HBC users due to inter-body coupling. This understanding will allow us to develop more secure and robust EQS-HBC based body area networks in the future.


Author(s):  
J.A. Nyenhuis ◽  
A.V. Kildishev ◽  
T.W. Athey ◽  
J.D. Bourland ◽  
K.S. Foster ◽  
...  