scholarly journals DISSYMMETRIC ANALYSIS OF PHASE TRANSITIONS IN THE AGGREGATE STATE OF A SUBSTANCE.

2021 ◽  
Vol 101 (09) ◽  
pp. 259-263
Author(s):  
Ulugbek Rakhmatulla ugli Bekpulatov ◽  
2017 ◽  
Vol 2017 (1) ◽  
pp. 6-11
Author(s):  
Юрий Дубров ◽  
Yuriy Dubrov ◽  
Александр Чукарин ◽  
Дмитрий Дубров ◽  
Dmitriy Dubrov ◽  
...  

The mathematical model of heat exchange in a cooling system of the combined cutting tools in case of dry cutting is provided. Absorption of heat is reached in case of change of aggregate state of fusible substances and is based on application of phase transitions of the first sort. As a result of the solution of a task of Stefan cutting process thermostabilization duration time is determined.


Author(s):  
G. Timp ◽  
L. Salamanca-Riba ◽  
L.W. Hobbs ◽  
G. Dresselhaus ◽  
M.S. Dresselhaus

Electron microscopy can be used to study structures and phase transitions occurring in graphite intercalations compounds. The fundamental symmetry in graphite intercalation compounds is the staging periodicity whereby each intercalate layer is separated by n graphite layers, n denoting the stage index. The currently accepted model for intercalation proposed by Herold and Daumas assumes that the sample contains equal amounts of intercalant between any two graphite layers and staged regions are confined to domains. Specifically, in a stage 2 compound, the Herold-Daumas domain wall model predicts a pleated lattice plane structure.


Author(s):  
Oleg Bostanjoglo ◽  
Peter Thomsen-Schmidt

Thin GexTe1-x (x = 0.15-0.8) were studied as a model substance of a composite semiconductor film, in addition being of interest for optical storage material. Two complementary modes of time-resolved TEM were used to trace the phase transitions, induced by an attached Q-switched (50 ns FWHM) and frequency doubled (532 nm) Nd:YAG laser. The laser radiation was focused onto the specimen within the TEM to a 20 μm spot (FWHM). Discrete intermediate states were visualized by short-exposure time doubleframe imaging /1,2/. The full history of a transformation was gained by tracking the electron image intensity with photomultiplier and storage oscilloscopes (space/time resolution 100 nm/3 ns) /3/. In order to avoid radiation damage by the probing electron beam to detector and specimen, the beam is pulsed in this continuous mode of time-resolved TEM,too.Short events ( <2 μs) are followed by illuminating with an extended single electron pulse (fig. 1c)


Author(s):  
Rohan Abeyaratne ◽  
James K. Knowles
Keyword(s):  

Author(s):  
Lorenza Saitta ◽  
Attilio Giordana ◽  
Antoine Cornuejols

Sign in / Sign up

Export Citation Format

Share Document